Phoenix G2 IDU User Manual OVERVIEW
SAF Tehnika JSC
10
Figure 1.7
PhoeniX G2 IDU interfaces
DC port
48V power supply connection. Input DC voltage operating range is -40.5V to -57V (max current
up to 3A). 4-wire DC power connector with screw terminals included. Polarity layout indicated
on the front panel. Any 2 wire power cable of good quality which fits well in SAF Tehnika’s
supplied 4 pole “screw on” power connector could be used.
4xSFP ports
SFP slots 1 to 4 for Gigabit Ethernet traffic. Any type of SFP modules can be used (Single-
mode or Multi-mode optical fibre). SFP ports are used also for interconnecting IDUs in case of
1+1 full protection configuration, and for IDU interconnection with EMM modules. 2.5 Gbps
optical fibre cable and SFP modules must be used to interconnect Phoenix G2 IDUs in 1+1 full
protection mode. 1 Gbps optical fibre cable and SFP modules can be used to interconnect
Phoenix G2 IDU with EMM modules.
LAN1, LAN2 ports
10/100/1000Base-Tx Ethernet traffic ports (RJ-45)
MNG LAN3 port
10/100/1000Base-Tx port, which is out-of-band management by default and provides access
to the management via web GUI, Telnet or SSH communication facilities. It can be re-
configured for traffic purposes as well
HOST USB port
USB port reserved for flash memory
MNG USB port
USB mini port dedicated for local management access via its own IP address.