O U T D O O R   U N I T   A N D   A N T E N N A  

13 

Cable Interface 

There are two functions accomplished in the cable interface: 

 

The power supply of the radio unit, 

 

The provision of signal transportation to the IDU over the coaxial cable. 

The supply voltage, which can be in the range from 20 to 60 V with both polarities in relation to 

the ground, is supplied from the IDU over the cable. 
A 350 MHz frequency signal, modulated with the filtered data signal, is received from the IDU. 

The cable interface contains the FM demodulation unit. The data signal from the output of the FM 
demodulation unit is forwarded to the modulation input of the voltage-controlled oscillator in the 

transmitting part of the synthesizer module. Thus the data signal is transported from the IDU to 
the ODU. The cable can be so long until the maximum attenuation of the signal does not exceed 

20 dB. The FM demodulators produce a voltage, which is proportional to the logarithm of the 350 
MHz carrier power (cable RSSI). This voltage is supplied to the controller module and is used to 

check if the allowed length of the coaxial cable is not exceeded. 
The transportation of the data signal from the ODU to the IDU is carried out as follows: limited 

(constant level) 140 MHz intermediate frequency signal is supplied to the coaxial cable through the 
amplifier  and  the  band-pass  filter  in  the  cable  interface.  This  signal  is  frequency-modulated  (the 

modulation is performed in the transmitter of the opposite station) and the length of the cable has 
no effect on the transmitted data signal, unless the 20 dB attenuation limit is kept up. Since the 

filtration  and  restriction  of  the  intermediate  frequency  signal  is  performed  in  the  radio  unit,  the 
transportation of the signal to the IDU has no effect on the sensitivity of the receiver. 

Additional data signal with a transmission rate of 9 kbps is transmitted over the same coaxial cable 
from the IDU to the ODU and vice versa. Both signals carry telemetry data between ODU and 

IDU.  This  is  performed  using  two  carriers  with  pulse-modulated  amplitude.  The  data  from  the 
ODU  to  the  IDU  are  transmitted  on  a  6 MHz  carrier,  but  from  the  IDU  to  the  ODU  –  on  a 

4.5 MHz carrier. 

Intermediate Frequency Module 

The  IF  module  is  used  for  the  second  conversion  and  filtering  of  the  signal.  The  1542  MHz 
intermediate  frequency  signal  is  passed  to  the  IF  block  from  the  first  converter  in  the  receiver. 

Synthesized 1402 MHz oscillator jointly with a mixer transforms the first intermediate frequency 
into the second intermediate frequency of 140 MHz. The second IF signal is filtered with a surface 

acoustic waves (SAW) filter, after the filtering the signal arrives to the logarithmic amplifier that 
has a signal limiter at the output. The logarithmic amplifier has an additional function – an exact 

measurement of the power of the received signal. The direct voltage on the output of this amplifier 
is supplied to the controller module and is used for the measurements. 

Synthesizer Module 

The synthesizer module has two very similar frequency synthesizers. One synthesizer supplies the 
oscillator signal to the first mixer. The second has a modulation input and it supplies the signal to 

the  transmitter.  The  synthesizers  are  based  on  the  voltage-controlled  oscillators  (VCO).  The 
frequency of VCOs is stabilized and modified, using a phase-locked loop (PLL). 

Receiver 

The  receiver  performs  amplification  of  the  received  signal  by  means  of  a  low-noise  amplifier 

(LNA), which is a monolithic microwave integrated circuit (MMIC), enclosed in a special package. 
The signal after that is forwarded to the mirror-channel filter, which is installed with the purpose 

to reduce the noise factor of the receiver. From the point of view of the input signal, sufficient 
attenuation of the mirror channel is provided by the duplexer filter. 

The amplified signal is passed to the subharmonic mixer, where it is converted to the frequency of 
1542 MHz. This mixer is also a monolithic microwave integrated circuit. 

RX block has a waveguide input. 

Содержание CFM-LM Series

Страница 1: ...SAF CFM LM Series Microwave Radio System Product Family Technical Description SAF Tehnika A S 2005...

Страница 2: ...SAF CFM LM Series Product Family Technical Description SAF Tehnika A S 2005 Phone 371 7046840 Fax 371 7020009...

Страница 3: ...eneral 33 IDU Functional Design 37 Updating Management Controller Software39 C H A P T E R 5 Cables 40 IDU ODU Cable 40 Cable for Antenna Alignment 41 Traffic Interface Cables 42 Management Interface...

Страница 4: ...ments of ETSI EN 300 198 standard CFM 18 LM operates in 18 GHz band WAN data rates 8 16 34 Mbps the CFM 18 LM meets the requirements of ETSI EN 301 128 standard CFM 15 LM operates in 15 GHz band WAN d...

Страница 5: ...By combining unified LM Radio Unit model with the choice from available LM Indoor Units it is possible to make the right configuration for wide range of data and voice transmission needs CFM radio sys...

Страница 6: ...us two interface slots that can be equipped with two interface modules V 35 E1 or 10Base T Ethernet providing additional traffic interfaces with a maximum capacity of 2 Mbps each Modular multiplexer I...

Страница 7: ...d without affecting the antenna alignment The IDU unit is fitted in 19 rack or on the wall or desk The management facilities of all SAF Tehnika products are being continuously developed and improved m...

Страница 8: ...MHz The duplex spacing of the CFM 8 LM radio is 119 MHz and 266 MHz The duplex spacing of the CFM 13 LM radio is 266 MHz The duplex spacing of the CFM 15 LM radio is 728 MHz 420 MHz and 490 MHz The du...

Страница 9: ...2 interface specification EN 301 216 v 1 2 1 2001 07 In the range 3 GHz to 11 GHz Plesiochronous Digital Hierarchy PDH Low and medium capacity and STM 0 digital radio system operating in the frequency...

Страница 10: ...in digital networks which are based on the 2048 kbit s hierarchy ITU T G 921 Digital sections based on the 2048 kbit s hierarchy ITU R ITU R F 385 6 Annex 1 7 425 7 725 GHz Duplex spacing 154 MHz ITU...

Страница 11: ...Manual see chapter References for more information Repeater Site At certain conditions it may become necessary to install one or more repeater sites With the existing equipment it is possible to estab...

Страница 12: ...tdoor part of the CFM site one side of the hop The Outdoor Unit is a radio unit which can be either directly connected to the antenna or installed separately using flexible waveguide The Radio Unit is...

Страница 13: ...hnical parameters please refer to Chapter Technical Data page 53 Relation of RSSI Rx signal level and received power is specified in the configuration guide see References The ODUs have the following...

Страница 14: ...ormal operational condition and should be averted as soon as possible Labelling Each Outdoor Unit is labelled The ODU is uniquely identified by the combination of product number P N and serial number...

Страница 15: ...er to Figure 4 Cable interface IF module Receiver Transmitter units Controller module Synthesizer module Duplexer Figure 4 The CFM LM radio unit block diagram Waveguide to Antenna Coax cable to IDU RX...

Страница 16: ...the IDU to the ODU and vice versa Both signals carry telemetry data between ODU and IDU This is performed using two carriers with pulse modulated amplitude The data from the ODU to the IDU are transm...

Страница 17: ...he output power Switching the receiver on and off The checking functions are provided for Measuring the level of the received signal Measuring the signal attenuation in the cable Checking the synchron...

Страница 18: ...7557 50 7711 50 15 7561 00 7715 00 16 7564 50 7718 50 17 7568 00 7722 00 Centre frequencies in subband C MHz Table 2 Tx Rx channel centre frequencies for the CFM 7 LM series Radio operating in 7 GHz b...

Страница 19: ...uencies 3 5 MHz step for the CFM 8 LM series Radio operating in 8 GHz band with the duplex shift of 266 MHz the CFM 8 LM ODU operates with the channel spacings 7 MHz for 8 Mbps capacity 14 MHz for 16...

Страница 20: ...5 28 12950 5 13216 5 13 12845 5 13111 5 29 12957 5 13223 5 14 12852 5 13118 5 30 12964 5 13230 5 15 12859 5 13125 5 31 12971 5 13237 5 Table 7 Tx Rx channel centre frequencies for the CFM 13 LM serie...

Страница 21: ...3 5 6 14546 5 15274 5 14 14602 5 15330 5 7 14553 5 15281 5 15 14609 5 15337 5 Table 10 Tx Rx channel centre frequencies for the CFM 15 LM series Radio operating in 15 GHz band with the channel spacing...

Страница 22: ...903 5 15323 5 13 14595 5 15015 5 28 14700 5 15120 5 43 14805 5 15225 5 58 14910 5 15330 5 14 14602 5 15022 5 29 14707 5 15127 5 44 14812 5 15232 5 59 14917 5 15337 5 Table 13 Tx Rx channel centre freq...

Страница 23: ...00 29 15 14504 50 14994 50 93 47 14728 50 15218 50 30 14508 00 14998 00 94 14732 00 15222 00 31 16 14511 50 15001 50 95 48 14735 50 15225 50 32 8 14515 00 15005 00 96 24 14739 00 15229 00 33 17 14518...

Страница 24: ...57 18497 50 19507 50 23 18030 00 19040 00 58 18511 25 19521 25 24 18043 75 19053 75 59 18525 00 19535 00 25 18057 50 19067 50 60 18538 75 19548 75 26 18071 25 19081 25 61 18552 50 19562 50 27 18085 0...

Страница 25: ...25 00 48 18062 50 19072 50 81 18310 00 19320 00 114 18557 50 19567 50 16 17822 50 18832 50 49 18070 00 19080 00 82 18317 50 19327 50 115 18565 00 19575 00 17 17830 00 18840 00 50 18077 50 19087 50 83...

Страница 26: ...17 5 114 22403 5 23411 5 32 22116 5 23124 5 116 22410 5 23418 5 34 22123 5 23131 5 118 22417 5 23425 5 36 22130 5 23138 5 120 22424 5 23432 5 38 22137 5 23145 5 122 22431 5 23439 5 40 22144 5 23152 5...

Страница 27: ...3177 131 22463 23471 51 22183 23191 135 22477 23485 55 22197 23205 139 22491 23499 59 22211 23219 143 22505 23513 63 22225 23233 147 22519 23527 67 22239 23247 151 22533 23541 71 22253 23261 155 22547...

Страница 28: ...21346 5 22578 5 57 21626 5 22858 5 97 21906 5 23138 5 137 22186 5 23418 5 18 21353 5 22585 5 58 21633 5 22865 5 98 21913 5 23145 5 138 22193 5 23425 5 19 21360 5 22592 5 59 21640 5 22872 5 99 21920 5...

Страница 29: ...2239 23471 13 21413 22645 33 21693 22925 53 21973 23205 73 22253 23485 14 21427 22659 34 21707 22939 54 21987 23219 74 22267 23499 15 21441 22673 35 21721 22953 55 22001 23233 75 22281 23513 16 21455...

Страница 30: ...092 5 108 25308 5 26316 5 13 24643 5 25651 5 45 24867 5 25875 5 77 25091 5 26099 5 109 25315 5 26323 5 14 24650 5 25658 5 46 24874 5 25882 5 78 25098 5 26106 5 110 25322 5 26330 5 15 24657 5 25665 5 4...

Страница 31: ...78 20 24836 25844 52 25284 26292 21 24850 25858 53 25298 26306 22 24864 25872 54 25312 26320 23 24878 25886 55 25326 26334 24 24892 25900 56 25340 26348 25 24906 25914 57 25354 26362 26 24920 25928 58...

Страница 32: ...6 38013 5 39273 5 17 37180 5 38440 5 57 37460 5 38720 5 97 37740 5 39000 5 137 38020 5 39280 5 18 37187 5 38447 5 58 37467 5 38727 5 98 37747 5 39007 5 138 38027 5 39287 5 19 37194 5 38454 5 59 37474...

Страница 33: ...8073 39333 13 37247 38507 33 37527 38787 53 37807 39067 73 38087 39347 14 37261 38521 34 37541 38801 54 37821 39081 74 38101 39361 15 37275 38535 35 37555 38815 55 37835 39095 75 38115 39375 16 37289...

Страница 34: ...wing 30 cm parabolic antennas are offered Model Product code Frequency range CFM 13 ANT C13A3002 12 75 13 25 GHz CFM 15 ANT C15A3002 14 4 15 35 GHz CFM 18 ANT C18A3002 17 7 19 7 GHz CFM 22 ANT C22A300...

Страница 35: ...5 GHz CFM 18 ANT C18A1802 17 7 19 7 GHz CFM 22 ANT C22A1803 21 2 23 6 GHz 240 cm parabolic antennas manufactured by COMHAT PROVEXA The following 240 cm parabolic antennas are offered Model Product cod...

Страница 36: ...weather protected equipment shelters or inside buildings Each of the IDU terminals is implemented as 19 rack mountable aluminium 1U high unit with the exception of 1 1 CFM MP MUX IDU which is 2U high...

Страница 37: ...ble and E1 interface cable As a minimum of 10 cm to 12 cm of supplementary space is required mainly depending on the RF cable type behind the IDU for management interface cables and RF cable CFM 8 REB...

Страница 38: ...rate of 16 Mbps 48V CFM 8 MUX SL RA CLEAR ENTER OUT IN E1 TX AIS LB R X C D S R V 35 REB TX RX TX RX LAN WAN REB TX RX TX RX LAN WAN Figure 9 The CFM 8 MUX IDU front panel CFM E1 Indoor Units All CFM...

Страница 39: ...odules V 35 E1 4xE1 or 2 port 100Base T Ethernet supports WAN data rates of 8 Mbps 16 Mbps and 34 Mbps data rates are software selectable The CFM MP MUX IDU is 2U high Hidden reset button Ethernet man...

Страница 40: ...IDUs only Ethernet Interface board refers to the CFM 8 REB only Traffic interfaces Figure 12 The CFM series E1 IDU block diagram Figure 13 The CFM 8 REB IDU block diagram Cable Interface Management C...

Страница 41: ...tiplexing and demultiplexing of the WAN data channel into interface traffic channels and 16 kbps telemetry channel Traffic Interfaces The traffic interface provide physical interface between user equi...

Страница 42: ...b site Upload functionality is provided through management controller software monitor and is available via RS 232 serial port Upload could be performed from PC Laptop connected to serial port of IDU...

Страница 43: ...ntended to interconnect the Indoor Unit with the Outdoor Unit Any type of 50 cable of good quality can be used the cable should be equipped with N type male connectors on each end There are two N type...

Страница 44: ...l multimeter to the ODU RSSI port in order to adjust the antenna alignment a coaxial cable with BNC connector on one end and appropriate termination on other end can be used see example in Figure 14 F...

Страница 45: ...er to the CFM product configuration guides see References for more information Management Interface Cables Standard Ethernet patch cables should be used with management Ethernet port of the IDU Any st...

Страница 46: ...Indoor Unit houses intelligent management controller providing several services TCP IP stack RIP II routing SNMP server Web server Telnet client and server Command Line Interpreter TCP IP packets are...

Страница 47: ...B II RFC1213 standard MIB this way enabling easy integration of the CFM equipment into any SNMP managed network under any standards based SNMP management application or MIB browser for example HP Open...

Страница 48: ...erminal is connected with the IDU remotely through a telephone line In this case the modem which is connected with the IDU should be set to auto answer mode Ethernet port Ethernet port of the CFM LM I...

Страница 49: ...pabilities similar to ones available using on LCD Keypad and front panel LEDs Currently the Web interface functionality is available through the Ethernet management port and or service channel only Fi...

Страница 50: ...Low v_12 0 octets Restart 4 v_13 0 octets IDU t 27C v_14 0 octets RF Cable OFF SNMP QUERY FINISHED Sample of SNMP query of the CFM LM IDU Alarm Port The alarm port is an optional feature The alarm por...

Страница 51: ...interval only Baseband loopback Baseband loopback The modulated signal on the baseband modem output is immediately looped back to the receiving device There are two baseband loop tests available Anal...

Страница 52: ...Multiplexer Remote loop Local loop Analog Interface I C 2 bus Figure 17 The E1 interface module digital loopback for the modular IDUs equipped with the E1 interface module the analog and remote inter...

Страница 53: ...l the components is essential to achieve reliable operation and lightning protection It is important to earth both the ODU and the IDU using the same earthing circuit It is recommended to earth the ra...

Страница 54: ...culation Tool SAF Tehnika provides software MS Excel workbook to aid in the network planning considerations it allows the user to determine the major parameters of Tx Rx equipment according to the req...

Страница 55: ...of traffic interface for example CFM 8 4E1 IDU e g RJ 45 or BNC but not both The BU changes up to 16 E1 traffic ports from RJ 45 symmetrical electrical interface to BNC asymmetrical and vice versa con...

Страница 56: ...3 BNC connectors CFM 34 REBM 34 Mbps 10 100Base Tx 2x E1 or 10Base T or V 35 CFM 8 MUX 8 Mbps 3x E1 or 10Base T or V 35 CFM 16 MUX 16 Mbps 3x E1 or 10Base T or V 35 CFM 8 REB 8 Mbps 10Base T UTP Chann...

Страница 57: ...15 LM ODU 75 dBm 78 dBm CFM 18 LM ODU 74 dBm 77 dBm CFM 22 LM ODU 75 5 dBm 79 dBm CFM 26 LM ODU 73 dBm 78 dBm CFM 38 LM ODU 70 5 dBm 74 dBm Background BER ETS EN 300 198 method 10 11 Waveguide flange...

Страница 58: ...ht kg CFM 8 4E1 44x482x284 2 0 CFM 16 8E1 44x482x284 1 9 CFM 34 16E1 44x482x284 1 8 CFM 34 E3 44x482x284 1 7 CFM 34 REBM 44x482x284 2 1 CFM 8 MUX 44x482x284 1 7 CFM 16 MUX 44x482x284 1 8 CFM 8 REB 44x...

Страница 59: ...T E C H N I C A L D A T A 56 ODU mechanical parameters Dimensions mm 280 x 85 Weight kg 2 5 Figure 21 Dimensions of the CFM LM series ODU 85 280...

Страница 60: ...ETS 300 019 standard as included in EN 300 198 radio standard Indoor Unit is Climatic Class 3 1E compliant according to ETSI ETS 300 019 1 3 and are intended to be operational in weather protected lo...

Страница 61: ...dular Multiplexer Indoor Unit Management System Technical Description and Configuration Guide CFM MP MUX Indoor Unit Installation and Configuration Manual Product Family Technical Descriptions There a...

Страница 62: ...ng protection 49 Loop tests 47 M Management controller 37 Management interfaces 42 43 Management methods 42 43 Modulation 52 Multiplexer 37 O Operation and maintenance facilities 4 Outdoor part 9 Outd...

Страница 63: ...60 W Web interface 45...

Страница 64: ...61...

Отзывы: