EN
DIGIWAVE
III
37
7 - MAINTENANCE OF INSTALLATION
SOFTWARE UPDATE
This page is accessible in the menu Maintenance
. It allows updating software with a file from a USB key. This file is provided by Air Liquide
Welding to improve the power source functions. The user must chose the file on the USB key then launch loading by pressing on the transfer button.
The software version of every part of the installation can be identified in the page: Software identification.
WARNING
With every new version of software will be supplied a table of compatibility between the various software versions. We
recommend you to update the software with a compatible version under risk of losing internal data of the power source.
WARNING
We recommend you to make an installation backup before any software update.
WARNING
Do not touch the power supply or the USB key during the update, of having to restart completely the operation.
COUNTERS
This page contains several counters allowing simplifying the maintenance of wear parts and consumables management. Every counter is associated to a
threshold - tunable or not - if the associated counter goes over the threshold value, a warning is reported to the user requiring acknowledgment.
Item
Associated counter
Maintenance action to do
Contact tube
Striking number
Replacement
Nozzle
Time of welding
Cleaning
Cooling liquid
Time of activation of the
cooling unit
Draining
Spool (useful when only
one wire type is used)
Length of unwound wire
Changing of the spool – renewing of the stock
Sheathe
Time of wire feeding
Changing
Power source
Time of arc
filter cleaning, blowing
Once the maintenance action is done, the user can reset the concerned counter, and possibly adjust the threshold.
FAULTS HISTORY
This page displays the faults history of the power source, and for each default, the context of its occurrence.
The default log can be exported on an external storage medium.
FACTORY RESET AND INSTALLATION BACKUP
The factory reset function allows the user resetting all or a part of the internal data of the power source at the leaving factory state.
Several reset levels exist:
-
reset of the power source configuration
-
reset of the users list
-
reset of the installation
The user must choose the reset level then restart the installation. Re-boot your machine to make the settings effective.