SERVICE, MAINTENANCE, DISPOSAL : 

Cleaning : 

Do not use aggressive detergents (solvents etc.).    Apply soapy water to moist cloth or use 

household detergent.    Prevent fluid from penetrating into device.    Finish by polishing with dry 

soft cloth.    Remove dirt immediately. 

 

Service, maintenance : 

The appliance may only be opened by trained service technicians who are authorized by SAEHAN. 

 

Annual Calibration and Repair

 : 

It is recommended that this instrument be checked for accurate calibration annually. If the 

instrument has been dropped or there is reason the suspect that calibration is required, the 

instrument should be serviced immediately. Contact your supplier or call SAEHAN at +82-55-294-

0381, 24-hour phone support at +82-10-5282-0161, or send email to [email protected]

Additional product and service information can be obtained at www.saehanmedical.com. 

 

Disposal : 

Disposal of packaging and appliance must be carried out by operator according to valid national 

or regional law of the location where the appliance is used. 

 

Warranty :    Warranty claims shall be voided in case 

-

 

Our conditions in the operation manual are ignored. 

-

 

The appliance is used outside the described uses 

-

 

The appliance is modified or opened 

-

 

Mechanical damage and damage caused by media, liguids 

-

 

Natural wear and tear 

-

 

Non-intended use or electric installation 

-

 

The measuring system is overloaded 

-

 

Dropping the balance 

-

 

One year warranty.    Any defective unit caused by workmanship will be replaced with 

new unit. 

 

 

 

Содержание SH5002

Страница 1: ...SPRING HAND DYNAMOMETER SH5002 User Manual...

Страница 2: ...um grip Move pointer lever to zero with your finger allow three trials with each hand alternating The device should be checked for correct condition prior to each usage by a person familiar with prope...

Страница 3: ...sures up to 100kg 220 lbs 2 Cap Keep spring securely 3 Pointer Pointer on the dial indicates force exerted 4 Handle Grip Handle for gripping Adjustable for hand size 5 Base Base for handle 6 Grip size...

Страница 4: ...Scope of supply Device Soft case Operating instructions...

Страница 5: ...ynamometer so the second joint of the fingers fit snugly on the handle when gripping Hold the dynamometer with arm extended down about thigh level Make a maximal squeeze Don t let the dynamometer touc...

Страница 6: ...value displayed on the dial face and record it l Turn the pointer to set the pointer zero again Methods 1 Have the subject hold the spring hand dynamometer with scale facing away from his face 2 Adjus...

Страница 7: ...CHILDREN DATA FOR SPRING GRIP TESTER TABLE 1 Averages of Strength of Grip In kg for childrn ADULT DATA FOR SPRING GRIP TESTER TABLE 2 Averages of Strength of Grip In kg for ADULT...

Страница 8: ...H mm Weight Approx 0 684kg 1 5 pounds TRANSPORTATION STORAGE CONDITION Environment 1 General It is not aimed to be used in households It is used in physical therapy rooms doctors offices and patients...

Страница 9: ...t your supplier or call SAEHAN at 82 55 294 0381 24 hour phone support at 82 10 5282 0161 or send email to saehancorp naver com Additional product and service information can be obtained at www saehan...

Страница 10: ...de Catalogue number Caution Fragile handle with care Keep dry Keep away from sunlight Consult instructions for use If there has been occurred any serious accident in relation to the our device release...

Страница 11: ...13 gil Masanhoewon gu Changwon si Gyeongsangnam do 51342 South Korea Phone 82 55 294 0381 Fax 82 55 293 5019 E mail saehancorp naver com Website www saehanmedical com MVS In Motion Westdijk 150 2830 T...

Отзывы: