INTELIA 05 TROUBLESHOOTING
Saeco International Group
Rev. 02 / September 2012
Page / 22
Operational check - coffee grinder and boiler
Initial Status
Initial Status
Press the aroma button to activate the coffee grinder
Temperature control
Press the coffee button to activate the boiler
The coffee grinder starts to spin and the number of pulses is indicated by the
The coffee grinder starts to spin and the number of pulses is indicated by the
number circled in red, the other numbers have no signi
fi
cance for this test.
number circled in red, the other numbers have no signi
fi
cance for this test.
ERROR:
ERROR:
If the number remains 0, the display changes to red, and the motor runs, the
If the number remains 0, the display changes to red, and the motor runs, the
problem lies in the Hall sensors, or their wiring, or in the CPU/POWER input
problem lies in the Hall sensors, or their wiring, or in the CPU/POWER input
(JP2). If the motor does not run, the problem may lie in the chain (JP8), the
(JP2). If the motor does not run, the problem may lie in the chain (JP8), the
coffee grinder wiring or the actual coffee grinder.
coffee grinder wiring or the actual coffee grinder.
The circled number expresses the boiler temperature in degrees centigrade.
The circled number expresses the boiler temperature in degrees centigrade.
ERROR:
ERROR:
If the HEATER indicator shows the word “SHORT”, this means that the NTC
If the HEATER indicator shows the word “SHORT”, this means that the NTC
temperature sensor is in short circuit. The display changes from green to red:
temperature sensor is in short circuit. The display changes from green to red:
in this case check the wiring on the NTC or the CPU/POWER inlet (JP13).
in this case check the wiring on the NTC or the CPU/POWER inlet (JP13).
ERROR:
ERROR:
If the HEATER indicator displays the word “OPEN”, this means that the NTC
If the HEATER indicator displays the word “OPEN”, this means that the NTC
temperature sensor is disconnected; the display changes from green to red;
temperature sensor is disconnected; the display changes from green to red;
in this case check the continuity of the NTC wiring, and check the connection
in this case check the continuity of the NTC wiring, and check the connection
to the CPU/POWER in (JP13).
to the CPU/POWER in (JP13).
The indicator changes from “OFF” to “ON” and shortly after the temperature
The indicator changes from “OFF” to “ON” and shortly after the temperature
indicator should start to increase, and the ammeter on the counter must dis-
indicator should start to increase, and the ammeter on the counter must dis-
play an absorption of approximately 8 Ampere with 230 volt.
play an absorption of approximately 8 Ampere with 230 volt.
There is a further check to carry out if the temperature goes above 125°C
There is a further check to carry out if the temperature goes above 125°C
then the display changes to yellow and an alarm message appears on the
then the display changes to yellow and an alarm message appears on the
display. Above this temperature the boiler is always off, avoiding the risk of
display. Above this temperature the boiler is always off, avoiding the risk of
dangerously high temperatures.
dangerously high temperatures.
ERROR:
ERROR:
If the temperature is not absorbed check the boiler resistor, relative wiring
If the temperature is not absorbed check the boiler resistor, relative wiring
and the connection to the CPU/POWER in (JP19), also check the wiring on the
and the connection to the CPU/POWER in (JP19), also check the wiring on the
NTC (JP13).
NTC (JP13).
15
Содержание Intelia
Страница 3: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 1 INTRODUCTION...
Страница 9: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Страница 13: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 3 USER INSTRUCTIONS...
Страница 24: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 4 OPERATING LOGIC...
Страница 33: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 5 TROUBLESHOOTING...
Страница 56: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 6 STANDARD CHECKS...
Страница 59: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 7 DISASSEMBLY...
Страница 71: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 8 NOTES...
Страница 72: ...INTELIA 08 NOTES Saeco International Group Rev 02 September 2012 Page 01 01...
Страница 73: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Страница 76: ...Saeco International Group Rev 02 September 2012 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM...
Страница 77: ...INTELIA 10 WIRING DIAGRAM Saeco International Group Rev 02 September 2012 Page 01 01 Intelia Focus and Class...