Содержание DisplayMax 600

Страница 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...

Страница 2: ...999 2000 2001 Sadelco Inc Patent Pending DisplayMax 600 47 600 MHz Scanning Signal Level Meter DisplayMax 600 CLI 47 600 MHz Scanning Signal Level Meter and Calibrated Leakage Detector DisplayMax 800 5 872 MHz Scanning Signal Level Meter With Sub Band and Ingress Sweep DisplayMax 800CLI 5 872 MHz Scanning Signal Level Meter and Calibrated Leakage Detector With Sub Band and Ingress Sweep Artisan Te...

Страница 3: ...or abnormal conditions of operation the warranty will become void In doubtful cases we will contact the purchaser for non warranty repair authorization Please notify us if an estimate is required Sadelco assumes no responsibility for its products being used in a hazardous manner either alone or in conjunction with other equipment Sadelco assumes no liability for secondary damages and in any event ...

Страница 4: ...tal Channel Measurement 16 Data Recording Printing and Downloading 17 Storage Capacity 17 Saving Measurements 17 Recalling and Deleting Files 17 Creating Excel Spreadsheets 17 Download to Windows 3 11 Terminal 18 Download to Windows 95 98 HyperTerminal 19 Print Direct to Serial Printer 19 24 Hour Testing 20 Hum 21 Carrier to Noise 22 Ingress Sweep 800 versions only 22 Leakage Detector CLI versions...

Страница 5: ...ents ESCAPE Escape functions or go back up menus FUNCTION Used to select Function modes indicated by blue markings LIGHT SETUP BATTERY Used with FNC to select these functions SAVE Stores measurements in memory ENTER In tuning modes completes numeric channel entries In Setup completes edits CLEAR Clears a channel entry before it is finalized with ENT ON OFF Manual Power Switch ALPHANUMERIC KEYS In ...

Страница 6: ... plan The Channel Plan name is located in the lower left corner of the display The factory default is EIA NCTA See Setup Menu Section 1 1 2 Make sure to select digital channels and delete unused channels See Setup Menu Section 1 2 3 Make sure the correct measurement units have been selected Measurement units appear on the right side of the display just above the Video Level The factory default is ...

Страница 7: ...s ENT to select this section 4 Use UP Down Arrows to highlight the desired line item within each Setup Section 5 Press ENT to select the line item for editing 6 When a line item has been selected it appears in the Edit Box at the bottom of the screen 7 Use UP Down Arrows or Alphanumeric Keys to edit the line item 8 Use Right Left Arrows to move the edit cursor position 9 Press ENT to complete each...

Страница 8: ...L PLAN is the first menu item and will already be highlighted Press ENT to select Use UP DOWN Arrow Keys to scroll to and highlight a different channel plan if desired Press ENT to select Press ESC to exit sub menu Press ESC to exit SETUP 1 2 Edit the Current Channel Plan DisplayMax allows separate editing of each plan Multiple copies of the most common plan EIA have been included for users who op...

Страница 9: ...highlighted Press ENT then use the alphanumeric keys The name will appear in the edit box To enter the letter A press the Number 2 Key twice Then Arrow Right for the next character When finished Press ENT to finalize the edit 1 3 Restore The Current Channel Plan This function lets you quickly restore the full unedited channel plan that has been selected All user edits to the plan will be deleted P...

Страница 10: ...ution DisplayMax is a precision instrument with automatic self calibration using a built in white noise reference This offset allows the user to adjust the gain or loss of all digital channels single channel or scanning mode by the same amount to match another instrument or external reference Before making any adjustments keep in mind that discrepancies of 2 0 dB between the readings of two signal...

Страница 11: ...mizable settings to other DisplayMax meters except the following Employee Name ID Number Clone Setting Channel Plans must be identical in both meters for Clone to transfer channel plan edits 6 0 Owner Identification User can enter the following Company Name Address Telephone Number Employee Name Employee ID Number 7 0 24 HR Test Change the following 24 HR Test Parameters Parameter Factory Defaults...

Страница 12: ...the Source meter to the Receive meter except the Employee Name Employee ID Number and the Clone setting Important Both Source and Receive meters must contain the same channel plans for a successful clone Receiving meter must have a frequency range equal to or greater than the Source Meter Both Source and Receive meters must be set to the same measurement units dBmV or dBuV before cloning To Clone ...

Страница 13: ...ature will reduce operating time Battery Life Typically 500 charge discharge cycles Replace only with Sadelco P N BAT06 The meter can be left on charge overnight It will automatically go to a trickle mode after it is fully charged Power Saving Functions To help increase the effective battery life there are three user adjustable features Power Auto Off Factory Default is 5 minutes Light Auto Off Fa...

Страница 14: ...rast Press FNC Up or Down Arrow Pop up instruction window will appear Press UP or Down as necessary Press ESC Audio Speaker In the signal level modes the audio speaker can only be used when tuning is restricted to a single channel or frequency When audio is available a loudspeaker icon appears press F4 to activate In the leakage detection modes audio is always available volume can be adjusted to f...

Страница 15: ...ys F1 F4 Test Location To change the cursor Channel Press Right or Left Arrow or use Number followed by ENT To change reference lines Press F2 to toggle between FCC 10 dB and None To change test location for check function Press F4 to toggle between Drop Ground Block Tap and User To check levels against limits Press F3 Check Inactive channels must be deleted in Setup for correct results See sectio...

Страница 16: ...an you can check the results against the FCC or your own limits Note Sub band is displayed in its own mode and is not included in full scan Note Make sure to delete unused channels in the Setup Mode to prevent incorrect Channel Fail messages when using the Check Key Zoom The Zoom mode displays a close up view of 15 channels at one time It will show seven channels on each side of the cursor channel...

Страница 17: ...The signal levels of both active scans and previously recorded ones can be instantly checked against FCC or user defined limits Four separate sets of limits Drop Ground Block Tap and User have been factory pre set Each of the four sets of limits can be edited by the user See Setup Menu Section 3 0 Edit check Limits The following automatic tests are performed for each active channel ANALOG Minimum ...

Страница 18: ... plan can be measured For measurement of smaller bandwidth signals such as telephony contact Sadelco In the single channel mode the full bandwidth of the channel is measured and displayed along with the average power This mode allows for the frequency response of the channel to be viewed and also allows for accurate measurement of any type of modulation QAM QPSK QPR VSB In any scan mode Full Sub F...

Страница 19: ...ation and the check limits Recalling and Deleting Files in the DisplayMax Files can be recalled and displayed one at a time on the DisplayMax Display Screen Once recalled the data can be checked against limits by pressing the F3 Check Key You can also change the test location by pressing F4 and then recheck the data again by pressing F3 You can even edit the check limits in Setup and then recheck ...

Страница 20: ... 8 Stop Bits 1 Parity None Flow Control None Connector COM1 or COM2 OK Click on Transfers then Receive Text File Select a destination Directory and a destination File Name Click OK On the DisplayMax Press the DLOAD PRINT RECALL DELETE Key Select a file using the UP DOWN arrows Press F2 PRT Repeat for each file you wish to download Note You can also download using the F1 DLD key however this key is...

Страница 21: ... you wish to download Note You can also download using the F1 DLD key however this key is intended for use with the DisplayMax Spreadsheet Software and will not download all of the file header information When the File Transfer is complete Click on Transfers Stop Exit Hyper Terminal You can now Print the File using any word processing program Note Hyper Terminal will not automatically create a new...

Страница 22: ...g a 24 HR Scan all keypad functions are locked out including the Manual On Off key In between scheduled scans you may use the DisplayMax in its regular modes If the DisplayMax is in operation when a scan is scheduled a pop up screen prompts the user to select one of the following options Start Scan Now Delay 5 Minutes Abort This Scan Abort Entire 24 Hr Test If no option is selected the scan will b...

Страница 23: ...tion of mono carriers and the normal higher modulation of stereo carriers may result in erroneous Hum readings Hum measurements should be made only on properly modulated mono audio carriers If the picture quality is good and Hum readings are high on several channels recheck Hum after turning off the audio modulation Hum Measurement on Unmodulated Audio carriers Turn off the audio modulation of the...

Страница 24: ...ital channel After turning on the digital channel measure it in the normal manner Compare the average power level of the noise to the average power of the active digital channel Ingress Sweep 800 versions only Connect the DisplayMax to the Tap end of a cable drop to check the whole house for any unwanted signals that are either being generated in the house or are finding their way into the house w...

Страница 25: ...o active video carrier at the default frequency because it has been deleted or you are in another channel plan the DisplayMax will tune to the default frequency and switch to the Frequency Tuning Mode Note The length of your dipole must be adjusted for frequency See chart below Default Mode Determines which mode Search or Measurement will be activated on turn on Once in the Leakage Mode F3 toggles...

Страница 26: ...ong with the faster one Antenna Considerations Each antenna type has different characteristics While only a dipole can be used for official CLI measurements it is unwieldy and difficult to handle Therefore the rubber duck or monopole may be a better choice when calibrated measurements are not necessary or when searching The Antenna Select feature in Leakage Setup automatically adjusts the leakage ...

Страница 27: ...Displaymax incorporates a proprietary feature patent pending that produces a 4 Hz warble when the received signal contains video specifically horizontal sync pulses This feature allows the user to quickly identify the received signal as a valid cable leak or dismiss it as a non cable signal Keep in mind however that a cable leak may be masked by a larger non cable signal If a non cable signal is n...

Страница 28: ... should be mounted in the center of the roof as long as there are no other conductors which would effect its performance If your vehicle is equipped with roof mounted ladder racks or a bucket you may want to experiment using a known leak to find the optimal position for the monopole Signal leaks are often hard to locate Rain and wet ground temperature changes and wind can all effect the level of l...

Страница 29: ...yMax Tune to the video carrier of a channel between 108 and 140 MHz Attach a dipole antenna of the correct length for the chosen frequency Select the Leakage Measurement mode Verify that 10 ft has been selected as a distance factor Extend the non conducting telescoping mast to 10 feet KEEP AWAY FROM ALL POWER LINES Orient the dipole so that it is parallel to the leak Rotate the antenna to achieve ...

Страница 30: ...n over product life Compensates for changes due to turn on drift temperature and aging of components AUTOMATED TESTING Scan Rate 6 Carriers sec Storage 43 Scans of 135 Channels each 99 Single Channel Measurements C N Range 50 dB with carrier level of 15 dB Accuracy 2 0 dB at 77 F 3 0 dB 0 120 F HUM Range 0 5 Filter 20 200 Hz TILT Automatically calculated from user Selected carriers AUDIO Adjustabl...

Страница 31: ...T1008 Rubber Duck Antenna supplied only with CLI packages ANT01 Download Software for Excel SW01 OPTIONAL ACCESSORIES Description Sadelco Part Number Strandhook Handle SH02 PC Download Cable CA10 Clone Cable CA20 220Volt AC Charger T70E Variable Dipole Antenna w 10 Ft extension pole ANT02 Magnetic Vehicle Mount Monopole Antenna ANT03 Artisan Technology Group Quality Instrumentation Guaranteed 888 ...

Страница 32: ...TR DCD 1 5 GND GND 5 6 6 Pin 6 s can be connected or not 7 RTS CTS 8 8 CTS RTS 7 9 9 Pin 9 s can be connected or not Sadelco Part No CA30 Modem Cable Use to connect DisplayMax to a standard 25 pin modem for remote operation 2 2 3 3 4 8 5 7 7 5 8 4 20 1 6 6 Pin 6 s can be connected or not 9 9 Pin 9 s can be connected or not 5 4 3 2 1 ο 9 8 7 6 5 4 3 2 1 ο 9 8 7 6 5 4 3 2 1 ο 9 8 7 ο 6 5 4 3 2 1 ο 9...

Страница 33: ...nector is used with short end connected to meter Also use flat and star washer with star washer making contact with metal housing Place duck antenna on a small jumper cable 2 to 3 ft If in the measurement mode make sure the correct antenna and antenna factor are selected If in the measurement mode make sure the correct distance to leak is entered Display Screen is too dark too light or not sharp U...

Страница 34: ...32 Notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 35: ...33 Notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 36: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: