Storage 

Storage Interval: 

 Battery should be stored in fully charged state. It is strictly prohibited to storage after discharge. 

 Battery storage location must be away from heat, sparks and smoke. 

 Battery must be stored in an upright position, avoiding impacts of external force or abrupt loads.   

Safety valve should be tightened. 

 It is strictly prohibited to stack battery without properly protective packaging.   

 Battery can be stored in -20

45

  environment. 

 

Storage 

temperature 

Maximum  storage  times  / 

Freshening charge intervals 

Recommended freshening charge method 

-20

25

 

Every 6 months 

Using constant current 0.1C

10

A

0.2C

10

A to 

charge battery bank till battery average voltage rises to 

equalizing charge voltage, then switch to constant 

voltage charging. Charging time is generally 16~24h. 

26

35

 

Every 3 months 

36

45

 

Every 2 months 

Maximum storage time (Shelf life) is 18 months (25

). 

 

Battery must be stored in a dry, ventilated and clean environment.   

 

Protect the battery from harsh weather, moisture, flooding, direct or indirect sun radiation,   

organic solvents, corrosive substances and gas. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operati

on 

and

 m

aintenanc

e

 

 

11

 

Содержание DCS Series

Страница 1: ...DCS Series Deep Cycle Solar Battery Technical Manual SHANDONG SACRED SUN POWER SOURCES CO LTD...

Страница 2: ...stic Curve 04 2 Charging Characteristic Curve 05 3 Cycle Performance Curve 05 4 Performance Data 06 Chapter III Operation and Maintenance 1 Safety Instructions 07 2 Operation Parameters 08 3 Factors I...

Страница 3: ...tive plates Negative plates Separators Container and Lid Posts sealing Terminal posts Electrolyte Vents Plates suspension Inter cell connectors Terminal hardware Product Introduction 01 Thick flat pas...

Страница 4: ...age V Nominal Capacity Ah 25 Dimensions mm Weight kg Short Circuit Current A Internal Resistance m 25 Terminal Type Terminal Layout C10 1 80V cell Length Width Height Total Height DCS12 50 12 50 350 1...

Страница 5: ...negative plate has not reached fully charged stage the process of active substance in negative plate transformed to spongy lead is not finished oxygen gas generated in positive plate reaches the nega...

Страница 6: ...1 describes the discharge curves of DCS Series at different discharge rate at ambient temperature 25 Table 2 1 describes the end voltage at different discharge rate Figure 2 1 Discharge characteristic...

Страница 7: ...arged the charge capacity can be as high as the 104 of the discharged capacity Figure 2 2 Charge characteristic curve Cycle Performance Curve At different depth of discharge the battery cycle life is...

Страница 8: ...16 0 12 0 9 60 5 60 2 28 1 200 1 056 0 562 1 90V 48 0 34 4 21 8 14 4 10 9 8 72 5 10 2 08 1 126 0 982 0 516 Constant power discharge data Table 2 3 DCS Series Battery Constant Power Discharge Data Shee...

Страница 9: ...ed by skilled personnel only Used batteries must be recycled and disposed properly as improper disposal of batteries is harmful to the environment and health Used batteries shall be properly disposed...

Страница 10: ...Hour in short is Ah Usually discharge rate is indicated through the suffix of C such as C10 means capacity at 10 hours discharge rate C3 means capacity at 3 hours discharge rate Battery capacity consi...

Страница 11: ...rted to C25 according to the following formula In the formula T Discharge temperature CT Capacity at temperature of T k Temperature coefficient k 0 006 at C10 discharge k 0 008 at C3 discharge k 0 01...

Страница 12: ...2 35 2 50V When battery float equalizing charge voltage according to the temperature compensation coefficient calculated values over the range according to the corresponding upper limit or lower limi...

Страница 13: ...orage temperature Maximum storage times Freshening charge intervals Recommended freshening charge method 20 25 Every 6 months Using constant current 0 1C10A 0 2C10A to charge battery bank till battery...

Страница 14: ...tainer temperature by using infrared thermometer 2 Use infrared thermometer to measure ambient temperature 1 Ambient Temp 20 45 2 Recommended Temperature 25 5 1 Check that the battery temperature comp...

Страница 15: ...Item Content Standard Maintenance 1 Measurement of each battery s floating voltage Measure each battery s floating voltage by using multimeter Battery floating voltage differential pressure must meet...

Страница 16: ...capacity to be maintained must be more than 80 and in energy storage use more than 60 of the reference capacity Recovery test measure and record various parameters specified in the monthly quarterly...

Страница 17: ...No 1 Shengyang Road Qufu City Shandong Province 273100 P R China Tel 0086 537 4422313 Fax 0086 537 4411980 E mail sales sacredsun cn...

Отзывы: