4. Operation 

4.1 Panel description 

Display
screen

Indication
light

Keys

 

          Front  panel  includes  three  parts  which  are  data  display  screen,  LED  power  supply  indication  light  and  operation 

keys. 

4.2 Instruction for operation keys 

Keys 

Measurement interface 

Programming interface 

自检

 

Switch main interfaces 

Select a bit or modify an item 

消音

 

Check more information at 

present interface in cycle   

Modify data at the selected bit or 

select an item 

Menu

翻页

 

Keep pressing it for 3 

seconds to enter 

programming mode 

Cancel or return to upper level menu 

通道

 

 

Confirm or enter next level menu 

 

4.3 Instruction for measurement interface 

Measurement interface 

Instruction 

 

Voltage value 

U = 201V 

 

Show current value of first circuit: I-01 = 258A, 

Press 

消音

  to check current value of other circuits (21 

circuits at most). 

 

Show total power P = 99.00MW 

Press 

消音

  to  check  power  value  of  other  circuits  (21 

circuits at most). 

 

Press 

消音

  to  check  export  energy  and  import/export 

energy of other circuits (21 circuits at most). 

 

Show the status of digital input 

 

Show the status of relay 

Содержание AR4DCT

Страница 1: ...1 AR4DCT DIN rail Multi function DC Power Meter User Manual...

Страница 2: ...N AND WIRING 4 3 1 DIMENSION 4 3 2 INSTALLATION 4 3 3 WIRING 5 TYPICAL WIRING 5 3 3 1 AR4DCT MR4DCT DIO 02 5 4 OPERATION 8 4 1 PANEL DESCRIPTION 8 4 2 INSTRUCTION FOR OPERATION KEYS 8 4 3 INSTRUCTION...

Страница 3: ...ation plugs without powering off Connect the terminal wires against the related instructions Please don t touch the terminals when the meter is in operation 2 Product description 2 1 Overview AR4DCT a...

Страница 4: ...sor input 4 4V Consumption 0 01VA each circuit Impedance 200k Power supply Working range AC DC 80 270 V Frequency 50 60 Hz Consumption 5VA Output Energy pulse Photoelectric isolation output pulse widt...

Страница 5: ...and demand only can be read through communication but not can be shown on the panel of meter 2 6 Digital input This meter supports 4 digital inputs The digital input uses the method of dry contact in...

Страница 6: ...ce of bus can be connected with 32 meters at most The start and end terminals of bus can be connected with terminal resistance 3 Installation and wiring 3 1 Dimension 3 1 1 AR4DCT main module dimensio...

Страница 7: ...5 3 3 Wiring Typical wiring 3 3 1 AR4DCT MR4DCT DIO 02 Other typical wiring...

Страница 8: ...R4DCT Voltage input input voltage should not be higher than 1500V 4 Current input input current should be connected via Hall sensor 5 Please make sure the directions of voltage an current are same 6 W...

Страница 9: ...input Voltage signal 11 14 Voltage input Energy pulse output 47 48 Active energy pulse output RS485 communication 58 59 Corresponding to A and B Relay output 15 17 2 relay outputs 16 is common end Di...

Страница 10: ...bit or select an item Menu Keep pressing it for 3 seconds to enter programming mode Cancel or return to upper level menu Confirm or enter next level menu 4 3 Instruction for measurement interface Mea...

Страница 11: ...rd input interface input the password defaulted password is 0001 through or key and press key to enter the setting interface if the password is correct Exit programming mode When the data or items in...

Страница 12: ...Import energy Export energy Energy pulse constant Unit imp kWh Clear demand Not clear demand Clear demand Clear energy Not clear energy Clear energy Input setting Rated voltage Unit V fixed value Curr...

Страница 13: ...ode Energy pulse width Voltage range Rated current of 1 circuit Alarm mode Alarm delay time Alarm hysteresis value Alarm value Cycle display interval LCD backlight duration Energy pulse constant Progr...

Страница 14: ...60s Save modified data and exit programming mode Menu 3s Menu Menu 5 3 Input signal setting User can set rated current value according to practical situation at field E g To set rated voltage value a...

Страница 15: ...operation process is as follows Enter programming interface select signal input setting menu Menu Menu 3s Menu Set relay working mode as alarm mode Alr Set relay pulse width as 10 0s Set alarm item a...

Страница 16: ...e subordinate machine addresses of normal meter and abnormal meter Besides you may check whether there is a fault in the meter by exchanging the installation positions of normal and abnormal meters Da...

Страница 17: ...er is negative The most common problem on spot is inlet and outlet wire of current transformer are in reverse connection Observe signed active power in split phase and it may be negative because of wr...

Отзывы: