background image

- 2 -

Video 15 SB 

Manual

2

Operating elements

Horizontal set-
ting of fluid
damping

Vertical brake

Clamping of the balance

plate (backside)

Vertical setting of
fluid damping

Counterbalance knob

Horizontal brake

Clamp
screw of
fluid head

Safety lock of 
Touch & Go System

Rosette for pan bar
fixing

Lever locking of 
Touch & Go
System

Camera plate

Touch
bubble

3

Operation

3.1 Intended use

This fluidhead was developed to enable pan-and tilt
movements of cameras. The maximum payload is speci-
fied in chapter 4.

Spare screws

Содержание Video 15 SB

Страница 1: ...Video 15 SB Fluid Head Fluidkopf Manual Benutzerinformation...

Страница 2: ...16 Postfach P O BOX 2039 D 85386 Eching D 85380 Eching Germany Germany Telefon 49 89 321 58 200 Telefax 49 89 321 58 227 E Mail contact sachtler de Homepage http www sachtler com We want you to recei...

Страница 3: ...3 3 3 Levelling of the fluid head 3 3 4 Mounting of the camera and or plate 4 3 5 Counterbalancing of the camera 4 3 6 Setting of the damping 5 3 7 Brakes 6 3 8 Change of the battery 6 3 9 Transport...

Страница 4: ...Fluidkopfes 13 3 4 Entnehmen und Einsetzen der Kamera platte 13 3 5 Einstellen der Kamerabalance 14 3 6 Einstellen der D mpfung 15 3 7 Bremsen 16 3 8 Austausch der Batterie 16 3 9 Transportstellung v...

Страница 5: ......

Страница 6: ......

Страница 7: ...w on the fluid head with a mounted camera the tripod must be secured against fall over Before releasing the vertical brake at a non balanced came ra set up or the clamping of the camera balance plate...

Страница 8: ...luid damping Counterbalance knob Horizontal brake Clamp screw of fluid head Safety lock of Touch Go System Rosette for pan bar fixing Lever locking of Touch Go System Camera plate Touch bubble 3 Opera...

Страница 9: ...fluid head is also possible For this it is advisable to relocate the clamp on the pan bar The pan bar has to be removed from the head and the black plastic cap on its top should be opened and removed...

Страница 10: ...y mounting the camera and or plate again it will lock automatically and the locking lever will snap back audibly into its initial position 3 5 Counterbalancing of the camera Before adjusting the count...

Страница 11: ...set up Adjusting the lower setting comes immediately effective The adjustment of the higher setting becomes effective after passing the 0 level while tilting the fluid head 3 6 Setting of the damping...

Страница 12: ...ed by one standard type button cell CR 2032 3 V located in the battery holder which can be opened with a sharp object such as a screwdriver Make sure to insert the new batteries according to the plus...

Страница 13: ...C 40 F to 60 C 140 F 2 8 kg 6 2 lb 12 Touch Go plate 16 1064 1 4 and 3 8 screws 100 mm bowl DV right 3470 diameter 18 22 32 mm 0 7 0 9 1 3 length 350 520 mm 13 8 20 5 Payload range Balance plate Grade...

Страница 14: ...tion If your camera remains front or back heavy after going through the necessary centring procedure paragraph 3 5 you may solve this by using the C O G plate Code No 1063 This plate offers a removed...

Страница 15: ...d was operated improperly or not in line with the specified technical data or the head housing was opened by unauthorised personnel We reserve the right to make changes based on technical advances Ple...

Страница 16: ...10 Video 15 SB Benutzerinformation...

Страница 17: ...erden Vor L sen der Klemmschale mu das Stativ bei aufgesetz ter Kamera gegen Umkippen gesichert werden Vor L sen der Vertikalbremse bei noch nicht eingestellter Kamerabalance oder der Klemmung der Kam...

Страница 18: ...chale Sperrknopf der Touch Go Klemmung Rosette f r Schwenkarm befestigung Kameraplatte Selbstleuchtende Libelle 3 Betrieb 3 1 Bestimmungsgem e Verwendung Der Fluidkopf wurde f r Schwenk und Neigebeweg...

Страница 19: ...chrauben schwarze Plastikkappe mit Hilfe einer M nze oder eines Schraubendrehers l sen und ent fernen Klemmst ck abnehmen umsetzen Plastikkappe wieder einschrauben und festziehen 3 3 Nivellieren des F...

Страница 20: ...hnappen 3 5 Einstellen der Kamerabalance Zur Einstellung der Kamerabalance ist es notwendig zuerst den Schwerpunkt der Kamera genau ber dem Drehpunkt des Fluidkopfes zu zentrieren Aktivieren Sie die v...

Страница 21: ...6 Einstellen der D mpfung Der Video 15 SB verf gt horizontal und vertikal ber je sieben D mpfungsstufen und eine Nullstellung Durch Drehen an den Steuerringen wird die gew nschte Fluidd mpfung eingest...

Страница 22: ...sich da die neuen Batterien entsprechend der plus Kennzeichnung des Batteriefaches eingelegt werden Eine Batterie reicht f r ca 2000 Beleuchtungsvorg nge 3 9 Transportstellung von D mpfung Gewichtsau...

Страница 23: ...ttlere Bohrung der Kameraplatte So kann eine Pin 1 4 Zoll Verbindung hergestellt werden falls dies f r eine Kamera ben tigt wird 1 kg bis 16 kg 70 mm Verschiebebereich je 7 horizontal vertikal und 0 9...

Страница 24: ...werden 5 2 Schwenkarme Der Video 15 SB wird mit dem Schwenkarm DV rechts 3470 geliefert Eine Aufnahme f r einen linken Schwenkarm ist am Fluidkopf vorhanden Die Bestell Nr f r den zweiten Schwenkarm...

Страница 25: ...d au erhalb der spezifizierten technischen Daten betrieben wurde oder das Grundgeh use von einer nicht autorisierten Service Stelle ge ffnet wurde nderungen die dem technischen Fortschritt dienen sind...

Страница 26: ...Video 15 SB Benutzerinformation www sachtler com...

Отзывы: