Manual
Reporter 650HS
- 2 -
3
Operation
3.1 Inserting the bulb
Please first adhere to the bulb manufacturer´s instructions
included in the packing.
➪
Do not touch quartz glass bulb with bare fingers.
Please do not use any bulb types, whose dimensions and
basic light data are not identical with the indicated basic
data. These bulb types are not suited and not permissible.
Suitable bulb types are:
LCL 46,5 mm
max. Ø 23 mm
650W
ANSI-Code
FRK (120V)
LIF-Code: CP89
FRL (230V)
FRM (240V)
500W
ANSI-Code
FRG (120V)
LIF-Code: CP82
FRH (230V)
FRJ (240V)
300W
ANSI-Code
FKW (120V)
LIF-Code: CP81
FSL (230V)
FSK (240V)
Open the luminaire by loosening the two knurled metal
screws on the side of the reflector housing until the thread
is visible. Pull reflector housing off.
When inserting the new bulb ensure that it is inserted cor-
rectly by pushing it firmly into the socket until it clicks into
position. The bulb must be aligned horizontally to the
socket level to avoid uneven light distribution. When putting
the reflector housing back in place, please ensure its cor-
rect positioning. This is the case when the opening of the
filter slot on the reflector housing faces upwards and the
focussing knob on the focus housing downwards. Fastening
of the laterally positioned knurled screws will close the
housing again.