2.9 Shipping Belt-Pack® batteries

For safety reasons ship batteries in discharged mode! Also
make sure that temperature is kept between minus 10°C
and 40°C (14°F and 104°F).

2.10 Self discharge and deep discharge

NiCd batteries discharge themselves at a rate of approx.
1% of the rated capacity per day – even if not used. Thus a
fully charged NiCd battery looses 50% of its capacity in
approx. 50 days. After approx. 100 days its voltage has
decreased to the end of discharge voltage: The battery is
virtually empty. Further storage without usage leads to the
deep discharging of the battery.
This status can be eliminated by running the battery
through several charge/discharge cycles. The full rated
capacity will be restored (see 2.6 Memory effect). During
the use it may happen that a battery is not automatically
disconnected at the end of discharge voltage (see 2.4 End
of discharge voltage) and accidentally becomes deep
discharged. If the battery is charged soon afterwards, the
full nominal capacity will be available immediately.

2.11 Power limits for Sachtler Belt-Pack® batteries

Based on the internal wiring and the connectors the power
drawn from Sachtler Belt-Pack® Batteries has to be within
the following limits:
Type

max. power

max. current

B1245, B1270

130W continuous 

10A continuous

200W short term 

15A short term

B3045, B3070

360W continuous 

12A continuous

600W short term 

20A short term

Drawing higher current than listed above may result in a
defective battery.

Содержание Belt-Pack B1245

Страница 1: ...Belt Pack Manual Bedienungsanleitung Battery 12V 30V Batterien 12V 30V...

Страница 2: ...usgabedatum Issue date 10 04 Bestellnr Order no leg14t010a sachtler GmbH Co KG Erfurter Strasse 16 Postfach P O BOX 2039 D 85386 Eching D 85380 Eching Germany Germany Telefon 49 89 32 15 82 00 Telefax...

Страница 3: ...7 New Belt Pack batteries 4 2 8 Storing Belt Pack batteries 5 2 9 Shipping Belt Pack batteries 5 2 10 Self discharge and deep discharge 5 2 11 Power limits for Sachtler Belt Pack batteries 6 3 Chargin...

Страница 4: ...zung 14 2 7 Neue Batterien 14 2 8 Batterielagerung 14 2 9 Batterietransport 15 2 10 Selbstentladung und Tiefentladung 15 2 11 Maximale Entnahmeleistung 15 3 Laden mit Ladeger t 16 3 1 Speedcharger Cod...

Страница 5: ...s Do not pack a warm battery into a transport case Do not charge a battery whilst in a transport case Do not over charge Do not short circuit A Sachtler Belt Pack high power battery can produce cur re...

Страница 6: ...iently at your hip If you carry the battery at the right side of your body the shoulder strap should rest on the left shoulder and vice versa Use the belt to lock the battery to your body 2 3 Open cir...

Страница 7: ...ched off since otherwise the battery will be deep discharged If deep discharge occurs several times the life time of the battery will be reduced considerably 2 5 Thermal properties Professional TV lig...

Страница 8: ...he end of discharge voltage 11V 25V resp 2 6 2 Reasons for capacity loss The memory effect should not be confused with a capacity loss caused by over charging or over hea ting since this capacity loss...

Страница 9: ...g the battery through several charge discharge cycles The full rated capacity will be restored see 2 6 Memory effect During the use it may happen that a battery is not automatically disconnected at th...

Страница 10: ...ed and charges the same amount of energy into the battery which was discharged before 3 2 Charger 12 Code Nr C1200 and Charger 12AS C1202 Compact overnight charger for Sachtler Belt Pack batte ries B1...

Страница 11: ...s not sufficient Remedy Is the socket plug damaged Has the battery been properly charged Is it exhausted Is the socket damaged If a Sachtler Speedcharger is used Is the temperature sensor defective Th...

Страница 12: ...mbient temperature Permissible cell temperature Size W x H x D Weight 13 2V 11 NiCd cells with nominal voltage 1 2V capacity selected 2 5 16 5V fully charged 11V B1245 4 5 Ah 60 Wh B1270 7 0 Ah 90 Wh...

Страница 13: ...10 6 lbs B3070 approx 7 0 kg 15 4 lbs Output nominal voltage Cells Open circuit voltage End of discharge voltage Nominal capacity Max output current Ambient temperature Permissible cell temperature S...

Страница 14: ......

Страница 15: ...rsonen sind von den Batterien und den damit betriebenen Ger ten fernzuhalten Packen Sie keine warme Batterie in den Transportkoffer Nicht im Transportkoffer laden Nicht berladen Nicht kurzschlie en Im...

Страница 16: ...kann Falls die Batterie auf der rechten Seite des K rpers getragen wird soll der Schultergurt auf der linken Seite ruhen und umgekehrt Mit dem H ftgurt wird die Batterie fest am K rper gehalten 2 3 L...

Страница 17: ...d was bei mehrmaliger Wiederholung zu einer Reduzierung der Lebensdauer der Batterie f hrt 2 5 Thermische Eigenschaften Leistungsstarke Leuchten ziehen hohe Entladestr me von mehreren Ampere aus der B...

Страница 18: ...och nach einer vollst ndigen Entladung bis zur Entladeschlu spannung 11V bzw 25V wieder erreicht 2 6 2 Abgrenzung Der Memory Effekt darf nicht verwechselt werden mit einem Kapazit tsverlust nach berla...

Страница 19: ...eladene Batterie noch 50 der Energie nach ca 100 Tagen ist sie v llig entladen Ein weiteres Lagern ohne Gebrauch f hrt zur sogenannten Tiefentladung der Batterie Dieser Zustand kann durch ein mehrmali...

Страница 20: ...orgesteuert alle wichtigen Batterieparameter berwacht und den Batterien nur so viel Energie wieder zuf hrt wie ihnen zuvor entnommen wurde 3 2 Charger 12 Code Nr C1200 und Charger 12AS C1202 Kompaktes...

Страница 21: ...hargers ersichtlich Ladeger t l dt nicht da Batterie zu hei 50 C oder zu kalt 10 C Batterie zu alt Anzahl der Ladezyklen Batterie berladen Batterie in hei em Zustand entladen Batterie zu kalt Fehler S...

Страница 22: ...ind vorbehalten 30V 25 NiCd Zellen je 1 2V Nennspannung selektiert auf Kapazit tsunterschiede von 2 5 max 35V bei vollgeladener Batterie 25V B3045 4 5 Ah 140 Wh B3070 7 0 Ah 210 Wh 12 A dauernd 20 A k...

Страница 23: ...25 Zellem 13 2V 11 Cells 11 Zellen Temperature control 3 Temperatur berwachung 2 1 nc 4 Frei 3 temperature control Tem peratur berwachung 2 charge Laden 1 4 discharge Entladen XLR Socket XLR Buchse X...

Страница 24: ...0 60 30 15 30 R 2 7 0 D Betriebsdauer Operation Time minutes Betriebsdauer Operation Time minutes R 2 5 0 H R 2 0 0 D R125D B3070 7Ah B3045 4 5Ah 45 60 Ladezeit Charge Time minutes Ladezeit Charge Tim...

Отзывы: