POWER INPUT

230 VAC 50/60HZ 0.06A 10W  

POWER INPUT

230 VAC 50/60HZ 0.06A 10W  

SeCtIon two — APPlICAtIonS

2.2.  FBX Setup for entire Mix

2.1.  FBX Setup for Monitors

2.3.  FBX Setup for Single Insert Point

2.4.  FBX Setup for Insert Send & return

right Main Send

left Main Send

Ch. B

IN

Ch. A

IN

All other Signal 

Processing

Ch. B

OUT

Ch. A

OUT

FILTERS

•  12  independent  digital  notch 

filters per channel,

 controlled au-

tomatically from 40 Hz to 20 KHz.

•  Filter width:

 user-controllable - either 

1/10 or 1/5 octave*, constant "Q" 

•  Resolution:

 1 Hz 

•  Time required to find and eliminate 

feedback:

 0.4 seconds, typical @ 1 

KHz

•  Number  of  Dynamic  vs.  Fixed 

filters  per  channel:

  user  select-

able.  Last  configuration  stored  in 

memory.

INPUT/OUTPUT**

•  Input/Output  Maximum  Signal 

Levels:

  Balanced  +18dBV  peak, 

unba12 dBV peak

•  Output  Drive:

  Unit  will  perform 

as  specified  driving  a  load  >600 

Ohms  

•  Input Impedance:

 Balanced or un-

balanced >40K Ohms, PIN 2 high

•  Output  Impedance:

  Balanced  or 

unbalanced 150 Ohms nominal, PIN 

2 high

•  Bypass:

 True power off bypass

•  Headroom:

 +14 dB peak @ 4 dBV 

nominal input, balanced

•  I/O  Connectors: 

XLR-3  and  1/4" 

TRS

PERFORMANCE***

•  Frequency response:

  20 Hz – 20 

KHz +/- 0.3 dB

•  Gain matching:

  +/- 0.2 dB

•  Spectral Variation: 

 + .25 dB, 20 

Hz to 20 KHz

•  SNR - Dynamic Range:

 >108 dB 

•  THD:

 .005% at 1 KHz

  < 0.01% 20 Hz – 10 KHz

  < 0.025% 10 KHz – 20 KHz

•  Dynamic Range:

 >105 dB

POWER INPUT

•  115 VAC:  100 – 130 VAC 50/60 

Hz

•  230 VAC:  200 – 240 VAC 50/60 

Hz

FUSE

•  115 VAC, 0.1 A, 10 W, 0.160 A SB 

fuse

•  230  VAC,  0.06A,  10  W,  0.080  A  T 

fuse

DIMENSIONS

•  1-U rack mount; 19 x 1.75 x 6.25 in. 

nominal (rack mountable); 48.3 x 4.5 

x 15.9 cm nominal

WEIGHT

•  8.0 lbs. (3.6 kg) nominal

OPERATING TEMPERATURE

•  Safe operating temperature: -15 to 

+50  degrees  centigrade  ambient 

temperature (5 to 122F)

SeCtIon tHree — enGIneerInG SPeCIFICAtIonS

TS or TRS Connectors

Ch. B OUT

Ch. A OUT

Ch. B IN

Ch. A IN

TS or TRS Connectors

Ch. 2

<

>

Insert 

Send

Insert 

Return

Ch. 1

<

>

Insert 

Send

Insert 

Return

IMPORTANT NOTE 

•  Use  a  ¼-inch TRS  plug  for 

balanced sends/inserts.

•  Use  a  ¼-inch  TS  plug  for 

unbalanced sends/inserts.

< Low Z >

< High Z >

<  Insert >

Ch. 1

Ch. 2

TRS Connector

TRS Connector

Y Insert Cords (TRS to TS + TS)

Ch. B OUT

Ch. B IN

Ch. A IN

TS "Y" Connector

Ch. A OUT

TS "Y" Connector

Monitor Mix 1

Monitor Mix 2

Ch. B

IN

Ch. A

IN

Ch. B

OUT

Ch. A

OUT

Tests performed using an Audio Precision 

System One model 322 or equal.

*Below  approximately  200  Hz  the  feedback  filters 

become slightly wider to increase the feedback and 

rumble capture speed at these low frequencies.

POWER INPUT

230 VAC 50/60HZ 0.06A 10W  

POWER INPUT

230 VAC 50/60HZ 0.06A 10W  

Содержание FBX2410

Страница 1: ...NG SPECIFICATIONS 3 SECTION FOUR OPERATING INSTRUCTIONS 4 4 1 Before You Begin 4 4 2 How To Operate your FBX2410 5 SECTION FIVE How to use FBX Features 6 5 1 Gain 6 5 2 FBX Filter Control 6 5 3 Import...

Страница 2: ...wer inlet incorporating a built in fuse holder To change the fuses in this socket 1 Disconnect the power cord from the unit 2 Pull out the fuse holder and remove the old fuse 3 Install a new fuse into...

Страница 3: ...e 20 Hz 20 KHz 0 3 dB Gain matching 0 2 dB Spectral Variation 25 dB 20 Hz to 20 KHz SNR Dynamic Range 108 dB THD 005 at 1 KHz 0 01 20 Hz 10 KHz 0 025 10 KHz 20 KHz Dynamic Range 105 dB POWER INPUT 115...

Страница 4: ...t by the user The system s gain before feedback is limited primarily by the number of fixed filters i e increasing the number of fixed filters increases the system s gain before feedback In addition y...

Страница 5: ...lter LEDs cycle back and forth in sequence This is your indication that the FBX is exiting setup mode IMPORTANT Reduce gain slightly You are now in READY perfor mance mode with the Fixed filters locke...

Страница 6: ...and if one isn t press the READY button before your program begins You ll know the FBX2410 is in setup mode when the SETUP button is lit NOTE You can manually override Setup mode if necessary 5 3 4 M...

Страница 7: ...signal level LED s on the unit light up 3 It may be patched in an effects loop not directly in the signal path This WILL NOT WORK 4 You may have used all 12 filters Dynamic filters will con tinue to...

Страница 8: ...erial intelligently distinguishing feedback from music or speech 2 A second advantage is that FBX micro filters are precisely placed anywhere feedback occurs with 1 Hz resolution while graphic EQ filt...

Страница 9: ...a total of 12 FBX filters combined fixed and dy namic which can be used as needed to exterminate feedback After years of experience and experimentation Sabine has settled upon a default balance of 10...

Страница 10: ...rent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B lim...

Страница 11: ...ume liability for personal injury or property damage arising out of or caused by a non Sabine alteration or attachment nor does Sabine assume any responsibility for damage to interconnected non Sabine...

Страница 12: ...mode You are ready to go The blue LED will flash Push READY again at any time to Lock Fixed filters the blue LED stays lit See the operating guide for more information on locking fixed filters Raise...

Отзывы: