SABINE FBX1200 Скачать руководство пользователя страница 2

2

1.  SETUP

Press and hold this button to begin the FBX setup mode. Filter
LEDs (light emitting diodes) will flash 5 times and the SETUP
LED will begin to flash. You are now ready to set FBX filters.

2.  READY

The READY LED lights when the automatic FBX setup pro-
cess has completed, or the READY button has been pressed.
This indicates your unit is ready for operation. The total num-
ber of filters available for feedback filtering is 12; in the factory
default setting, your unit will automatically enter READY mode
when the tenth filter is set. Alternatively, you may enter READY
status with fewer Fixed FBX filters in place, simply by pressing
the READY button at any time. Press READY again to lock the
Fixed filters.

3.  BYPASS

Bypass mode takes the unit out of the signal path so that it will
have no effect on the program. In active mode, the unit con-
trols feedback automatically. The red BYPASS LED lights when
the unit is in bypass mode.

4.  SIGNAL LEVEL

The LED ladder indicates the signal strength relative to the
FBX's input clip level.

SECTION ONE — FRONT & BACK PANELS

1.1.  FBX2400 Front Panel Controls & LED Indicators

9.  A/C Power Input

The FBX1200 & FBX2400 Series is factory configured to oper-
ate at either 115 VAC or 230 VAC. Using the wrong input volt-
age may cause permanent damage to the unit and will void the
warranty.

10.  Fuse

This equipment is fitted with an IEC power inlet incorporating a
built-in fuse holder.  To change the fuses in this socket:

1. Disconnect the power cord from the unit.

2. Pull out the fuse holder and remove the old fuse.

3. Install a new fuse into the holder. Replace only with one
of the following fuses:

• 115 VAC: 0.1 A, 10 W, 0.160 A SB fuse

• 230 VAC: 0.06A, 10 W, 0.080 A T fuse

4. Refit the fuse cover.

11. Power Switch

Previous settings retained during power-off.

12. Quarter-inch Output

TRS balanced  or TS Unbalanced output (using a TS unbal-
anced connector will result in loss of 6 dB gain).

Important: Refer to section 5.2.

13. Input/Output Level Switches

Set to match your desired Input/Output level configurations.

For unity gain set both switches to the same postion.

14. XLR Output

XLR balanced output.

15. Quarter-inch Input

TRS balanced or TS unbalanced input (mixing balanced and
unbalanced connections may result in a 6 dB loss of gain).

Important: Refer to section 5.2.

16. XLR Input

XLR balanced input.

1.2.  FBX2400 Back Panel Controls & Connections

5.  RESET DYNAMICS & DYNAMIC FILTER TIMER

Press and hold this button until the Dynamic filter flash and
LEDs go off to reset all Dynamic filters. See 

Section 5.2.4.

 for

enabling and setting the Dynamic Filter Timer.

6.  NUMBER FIXED

Set the number of available fixed filters by pressing the NUM-
BER FIXED button (

6

) until the LEDs stop flashing, then re-

lease it.  The LEDs (

8

) will begin to light in sequence.  When

the LED corresponding to the desired number of fixed filters
lights, press the Number Fixed button to register your selec-
tion.

7.  FIFTH OCTAVE

Press the button at any time to select wider filters for any new
filters to be set.  It is possible to have both 1/5 and 1/10 octave
constant "Q" filters active in one channel simultaneously.

8.  FILTER STAGE ACTIVITY

When one of the unit’s filters
is activated, the correspond-
ing LED lights.  A blinking
LED indicates the filter that
was most recently activated.

FILTER COLOR KEY

RED

= FBX Fixed, Locked

AMBER = FBX Fixed, Unlocked
GREEN = FBX Dynamic

8

4

2

1

3

5

7

6

12

14

12

14

13

13

15

16

15

16

10

11

9

13

13

Note: FBX1200 front and back panels

 use the same controls and

input/output configuration

Содержание FBX1200

Страница 1: ...or Insert Send Return 3 SECTION THREE ENGINEERING SPECIFICATIONS 3 SECTION FOUR OPERATING INSTRUCTIONS 4 4 1 Before You Begin 4 4 2 How To Operate your FBX1200 FBX2400 5 SECTION FIVE HOW TO USE FBX FEATURES 6 5 1 Input Output Level Switches 6 5 2 FBX Filter Control 6 5 3 Important Operating Considerations 7 SECTION SIX TROUBLESHOOTING TIPS 7 SECTION SEVEN FBX THEORY PRACTICE 8 7 1 Introduction to ...

Страница 2: ... 160 A SB fuse 230 VAC 0 06A 10 W 0 080 A T fuse 4 Refit the fuse cover 11 Power Switch Previous settings retained during power off 12 Quarter inch Output TRS balanced or TS Unbalanced output using a TS unbal anced connector will result in loss of 6 dB gain Important Refer to section 5 2 13 Input Output Level Switches Set to match your desired Input Output level configurations For unity gain set b...

Страница 3: ...20 KHz SNR Dynamic Range 100 dB THD 005 at 1 KHz 0 01 20 Hz 10 KHz 0 025 10 KHz 20 KHz Dynamic Range 105 dB POWER INPUT 115 VAC 100 130 VAC 50 60 Hz 230 VAC 200 240 VAC 50 60 Hz FUSE 115VAC 0 1A 10W 0 160ASBfuse 230 VAC 0 06A 10 W 0 080 A T fuse DIMENSIONS 1 U rack mount 19 x 1 75 x 6 25 in nominal rack mountable 48 3 x 4 5 x 15 9 cm nominal WEIGHT 8 0 lbs 3 6 kg nominal OPERATING TEMPERATURE Safe...

Страница 4: ...heir frequency center points until the unit is reset by the user The system s gain before feedback is limited primarily by the number of fixed filters i e increasing the number of fixed filters increases the system s gain before feedback In addition you can LOCK the fixed filters so they do not get any deeper Locked fixed filters are no longer adaptive The FBX s DYNAMIC FILTERS control intermitten...

Страница 5: ...ile you continue raising the gain until all filter LEDs cycle back and forth in sequence This is your indication that the FBX is exiting setup mode IMPORTANT Reduce gain slightly You are now in READY perfor mance mode with the Fixed filters locked and the blue Ready light on Begin the show c You may quit Setup mode at any time prior to its automatic exit by simply pressing the READY button blue RE...

Страница 6: ...ESET DY NAMICS until the current Dynamic filter LEDs flash and then turn off Re lease the button 5 2 4 Dynamic Filter Timer The Dynamic Filter Timer when enabled automatically resets Dynamic filters after a user selected time has passed refer to Timer Settings chart at right 5 2 4 1 Set the Dynamic Filter Timer 1 Press and hold the RESET DY NAMICS button The Dynamic LEDs flash twice and reset Con ...

Страница 7: ...oes one of the FILTERACTIVITY LEDs blink A The last filter to be automatically updated blinks During normal operation the blinking will move from filter to filter as they are reset This gives the user a visual confirmation that the unit is responding to new feedback and is function ing properly Q Sometimes during the initial setup the first filter LED will blink before any feedback has been introd...

Страница 8: ...ram material intelligently distinguishing feedback from music or speech 2 A second advantage is that FBX micro filters are precisely placed anywhere feedback occurs with 1 Hz resolution while graphic EQ filters are limited to 31 fixed center points An FBX filter represents a direct hit on feedback In contrast a graphic EQ filter can only approximate the exact frequency of the feedback and the filt...

Страница 9: ...0 offer a total of 12 FBX filters com bined fixed and dynamic which can be used as needed to exterminate feedback After years of experience and experimentation Sabine has settled upon a default balance of 9 fixed and 3 dynamic filters set at the factory This default condition can be changed to any combination you require If you follow setup instructions for setting FBX filters your FBX1200 FBX2400...

Страница 10: ... the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise emis sions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelectriques depassant ...

Страница 11: ...d by a non Sabine alteration or attachment nor does Sabine assume any responsibility for damage to interconnected non Sabine equipment that may result from the normal functioning and maintenance of the Sabine equipment UNDER NO CIRCUMSTANCES WILL SABINE BE LIABLE FOR ANY LOST PROFITS LOST SAVINGS ANY INCIDENTAL DAMAGES OR ANY CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRO...

Страница 12: ...Sabine Inc 13301 NW US Highway 441 Alachua Florida 32615 8544 USA Phone 386 418 2000 Fax 386 418 2001 Register your FBX equipment online at Sabine com ...

Отзывы: