Network Video Recorder Quick Start Guide
15
If you connect an AC load to the alarm output 3 of the NVR, then you must remove the JP 3
jumper.
2.3.3 Using Alarm Connectors
To connect alarm devices to the NVR:
Step 1
Disconnect
pluggable block
from the ALARM IN /ALARM OUT terminal block.
Step 2
Unfasten stop screws from the
pluggable block
, insert signal cables into slots and fasten stop
screws. Ensure signal cables are tight.
Step 3
Connect
pluggable block
back into terminal block.
2.3.4 Controller Connection
Figure 2-7
Controller Connection
To connect a controller to the NVR:
Step 1
Disconnect pluggable block from the KB terminal block.
Step 2
Unfasten stop screws from the KB D+, D-
pluggable block
, insert signal cables into slots and
fasten stop screws. Ensure signal cables are in tight.
Step 3
Connect Ta on controller to D+ on terminal block and Tb on controller to D- on terminal
block. Fasten stop screws.
Step 4
Connect
pluggable block
back into terminal block.
Make sure both the controller and NVR are grounded.