Chapter 6: ECG analysis and measurement
42
General information
In order to automatically analyze the ECG signal, the analysis and interpretation software of the University
of Glasgow (The Glasgow Program) has been added to DENA 650. This software helps in more accurate
diagnosis of the disease in two parts: Measurement and Interpretation. The Measurement section measures
and reports the important parameters of the ECG signal and the Interpretation section uses the results of the
Measurement section to diagnose the disease.
For best results, the physician must enter the patient's gender and age. It should be noted that the Glasgow
software analyzes and interprets 10 seconds of the ECG signal.
Reported parameters in Global mode
In Global mode, reported signal specifications, are not dependent on individual ECG leads and are generally
calculated for the ECG signal.
Table 6-1
Reported parameters in Global
Description
ECG parameters
Time interval from the beginning to the end of the P wave
P Duration [ms]
Time interval from the beginning of the P wave to the beginning of the Q wave
PR Interval [ms]
Time interval from the beginning of the Q wave to the end of the S wave
QRS Duration [ms]
Average time interval between two consecutive R peaks
RR Interval [ms]
Time interval from the beginning of the Q wave to the end of the T wave
QT Interval [ms]
Normalized QT based on RR Intervals
QTc Interval [ms]
Time interval from the beginning to the end of the T wave
T Duration [ms]
Time interval from the beginning to the end of the ST segment
ST Duration [ms]
Heart Axis
P/QRS/T/ST Axis
[degree]
Figure 6-1
Signal parameters in Global
Содержание Dena 650
Страница 1: ...User Manual Dena Electrocardiograph DENA 650 Linux AADAT Co D00912 7...
Страница 3: ......
Страница 11: ......
Страница 12: ...Chapter 1 Introduction 1 1 Introduction...
Страница 25: ...Chapter 1 Introduction 14...
Страница 26: ...Chapter 2 System settings 15 2 System settings...
Страница 38: ...Chapter 3 Patient information 27 3 Patient information...
Страница 41: ...Chapter 3 Patient information 30...
Страница 42: ...Chapter 4 Patient preparation 31 4 Patient preparation...
Страница 47: ...Chapter 4 Patient preparation 36 Lead Placement Diagram Figure 4 4 Lead placement digram...
Страница 48: ...Chapter 5 Recording Operation 37 5 Recording Operation...
Страница 52: ...Chapter 6 ECG analysis and measurement 41 6 ECG analysis and measurement...
Страница 58: ...Chapter 7 Data management 47 7 Data management...
Страница 64: ...Chapter 8 Care and Cleaning 53 8 Care and Cleaning...
Страница 71: ...Chapter 8 Care and Cleaning 60...
Страница 72: ...Chapter 9 Troubleshooting and Error messages 61 9 Troubleshooting and Error messages...
Страница 77: ...Chapter 9 Troubleshooting and Error messages 66...
Страница 78: ...Chapter 10 Technical specification 67 10 Technical specification...
Страница 81: ...Chapter 10 Technical specification 70...
Страница 82: ...Appendix 1 Accessories 71 Appendix 1 Accessories...
Страница 84: ...Appendix 2 System parameters 73 Appendix 2 system parameters...
Страница 87: ...Appendix 2 System parameters 76...
Страница 88: ...Appendix 3 Electromagnetic compliance EMC 77 Appendix 3 Electro magnetic compliance...
Страница 93: ...Appendix 3 Electromagnetic compliance EMC 82...
Страница 94: ...Appendix 4 The GLASGOW program 83 Appendix 4 The GLASGOW program...
Страница 101: ......