Check the lock washers located at the main potentiometer for brittleness.
Parts:
Lock washer (as necessary)
45 56 098
Figure 12.
Checking lock washers
1.
Operate the top using the “ROOF” switch until it is in the position shown above. The top, 5th bow and
neau cover should be fully raised.
I
2.
Verify that a lock washer is located by the main potentiometer. If not, install one.
3.
Lightly tap existing lock washer with a screwdriver to check for brittleness.
4.
Change any lock washers that show signs of cracking.