S3 0312FC Скачать руководство пользователя страница 46

 

Page | 43 

 

15.5

 

XX34FC: XXHP Full Centrifugal Fan 
(460/480, 3PH)  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.6

 

XX36FC: XXHP Full Centrifugal Fan 
(575/600, 3PH)  

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 0312FC

Страница 1: ......

Страница 2: ......

Страница 3: ...urbo Fans 22 8 5 Low Speed Centrifugal Fans 23 8 6 High Speed Centrifugal Fans 24 9 Performance 25 10 Installation Instructions 26 10 1 Mechanical Check 26 10 2 Foundation as Required For Fan 26 10 3...

Страница 4: ...understand ALL Safety Operating and Maintenance Information presented in this manual S3 AIR SYSTEMS recommends all personnel that intend to use the Aeration Fan read the operators manual and will foll...

Страница 5: ...chased the unit Be prepared to provide the information listed on the Serial Plate as well as the details of application i e bin diameter and type grain depth and type etc If further assistance is requ...

Страница 6: ...ious injury CAUTION indicates a potential hazard that if not avoided may result in minor or moderate injury NOTICE is used to address practices not related to personal injury 4 2 General Safety YOU ar...

Страница 7: ...o Hearing protection o Respirator or filter mask Make sure all persons are clear of the equipment when in operation Failure to follow any of the above warnings may cause serious bodily injury or death...

Страница 8: ...rotor may cause imbalance or excessive vibration Inspect daily thoroughly clean when necessary Keep hands feet and clothing away from moving parts especially the air intake area of the fan Do not cle...

Страница 9: ...in place Slowly peel back the remaining paper and carefully smooth the remaining portion of the decal in place Small air pockets can be pierced with a pin and smoothed out using the decal backing pap...

Страница 10: ...Page 7 Note Decal 9005 18 0026 for fan voltage rating of 480V Decal 9005 18 0227 for fan voltage rating of 600V 7 1 3 4 5 6 2...

Страница 11: ...Page 8...

Страница 12: ...has been designed for applications that require airflow at high static pressures The In Line Centrifugal Fan utilizes a centrifugal rotor and inlet specifically designed for smooth quiet efficient op...

Страница 13: ...ernal thermal protection Sealed capacitor motor starter built for trouble free operation Energy efficient operation Cool operation Unequalled dependability Quick start up Sealed bearings for long life...

Страница 14: ...al Protection in Starter 230 5HP 3PH 480V TEFC 184T 6 2 3450 1 4 F Thermal Protection in Starter 230 5HP 3PH 600V TEFC 184T 5 3450 1 3 F Thermal Protection in Starter 230 7 5HP 1PH 230V TEFC 215Z 30 5...

Страница 15: ...Starter 220 11 5 7 5HP 3PH 600V DPAO TEAO 9 4 3450 1 F Thermal Protection in Starter 220 10HP 1PH 230V DP TEAO 61 5 3450 1 15 1 0 F Thermal Protection in Starter 315 61 1 10HP 3PH 230V DP 40 3450 1 1...

Страница 16: ...in Starter 210 TEAO 9 5HP 3PH 600V DP 7 45 3450 1 F Thermal Protection in Starter 210 TEAO 7 5HP 1PH 230V DPAO 42 3450 1 3 1 0 F Thermal Protection in Starter 235 TEAO 38 1 7 5HP 3PH 230V DPAO 23 5 3...

Страница 17: ...6 3600 1 15 F Thermal Protection in Starter 640 59 1 2 25HP 3PH 480V TEFC 284TS 28 8 3600 1 15 F Thermal Protection in Starter 640 29 5 1 2 25HP 3PH 600V TEFC 284TS 23 3600 1 15 F Thermal Protection...

Страница 18: ...15HP 3PH 600V TEFC 254T 14 5 1750 1 15 F Thermal Protection in Starter 750 13 8 1 3 20HP 3PH 230V TEFC 256T 47 1750 1 15 F Thermal Protection in Starter 800 45 8 1 2 20HP 3PH 480V TEFC 256T 23 7 1750...

Страница 19: ...e 1 Motor Service Bulletin Motor Service Centres 1 Warranty Motor Warranty 1 Component Description Quantity Low High Speed Aeration Fan Low High Speed Fan Assembly 1 Manual Installation Operation Main...

Страница 20: ...0 1 Phase In Line Fans Single Phase 0312IL 135 3HP In Line Centrifugal Fan 230 1 Phase 0512IL 230 5HP In Line Centrifugal Fan 230 1 Phase 0712IL 260 7 5HP In Line Centrifugal Fan 230 1 Phase 1012IL 35...

Страница 21: ...30 3 Phase 0734FC 340 7 5HP Full Centrifugal Fan 460 480 3 Phase 0736FC 340 7 5HP Full Centrifugal Fan 575 600 3 Phase 1032FC 385 10HP Full Centrifugal Fan 230 3 Phase 1034FC 385 10HP Full Centrifugal...

Страница 22: ...e 1536IL 260 10HP In Line Centrifugal Fan 575 600 3 Phase Fan ID Wt lbs Description Low Speed Fans Three Phase 1032LS 515 10HP Low Speed Centrifugal Fan 230 3 Phase 1034LS 545 10HP Low Speed Centrifug...

Страница 23: ...e and 14 tall The 10 HP Full Centrifugal fan is designed to fit a bin duct which is 12 wide and 17 tall Overall dimensions of the FC line of fans are shown in the following images Fan Dimension 3HP 5H...

Страница 24: ...e dimensions shown in the following images Fan Dimension 3HP 5HP 7 5HP 10HP 15HP A Outlet B C D 19 3 4 25 3 4 25 3 4 29 3 4 29 3 4 B Outlet I D 18 1 2 24 1 16 24 1 16 28 1 8 28 1 8 C Length 25 5 8 25...

Страница 25: ...hown in the following images Fan Dimension 3HP 5HP 7 5HP 10HP 15HP A Outlet B C D 19 3 4 25 3 4 25 3 4 29 3 4 29 3 4 B Outlet I D 18 1 2 24 1 16 24 1 16 28 1 8 28 1 8 C Length 25 5 8 25 9 16 25 9 16 2...

Страница 26: ...ion 10HP 15HP 20HP 25HP 30HP A Outlet Width 16 18 19 5 8 22 22 B Outlet Height 29 5 8 29 3 4 33 1 4 33 1 4 33 1 4 C Length 46 46 51 11 16 51 7 8 54 3 4 D Body Width 22 24 24 5 8 27 27 E Width 36 1 2 4...

Страница 27: ...an Dimension 20HP 25HP 30HP 40HP A Outlet Width 11 3 8 11 3 8 14 14 B Outlet Height 25 25 25 25 C Length 37 15 16 37 15 16 37 15 16 37 15 16 D Body Width 17 3 8 17 3 8 20 20 E Width 36 5 8 37 1 8 40 7...

Страница 28: ...essure inches Airflow CFM 3450 RPM 3 HP 5 HP 7 1 2 HP 3 3850 4 3700 6000 5 3250 4500 5700 6 2800 4250 5400 7 2400 3600 5100 8 1250 3300 4700 9 2200 4100 10 3250 Development and testing of S3 AIR SYSTE...

Страница 29: ...per clearance and retighten Clearance of high efficiency fans are very small If the fan is dropped or impacted misalignment of rotor could occur this check should be repeated periodically Always check...

Страница 30: ...wall adapter as illustrated by the following image 10 3 2In Line Centrifugal Turbo Fan Installation The mounting outlet on S3 AIR SYSTEMS In Line Centrifugal Aeration Fan has a circular 8 hole flange...

Страница 31: ...pull it snug into the bin s duct Aeration fans are heavy A fan that is not securely suspended can cause serious injury or death if it falls on someone Whether chain cable straps or any other system i...

Страница 32: ...line frequency and load size 4 Disconnect all power services and stop the motor before servicing 5 For single phase motors discharge the start and or run capacitors before servicing 6 Do not by pass...

Страница 33: ...er s specific Motor Installation Maintenance Manual diagram The wiring fusing and grounding must comply with the National Electrical Code and local codes When the motor is connected to the load for pr...

Страница 34: ...ese fans on flip and hold the switch in the ON position for a short period of time Release the switch The fan should start and run To turn these fans off flip the switch to the OFF position All Bin Se...

Страница 35: ...ifting lugs or lifting openings if provided are intended only for lifting the motor and motor mounted standard accessories not exceeding in total 30 of the motor weight These lifting provisions should...

Страница 36: ...in lubrication Any grease used to lubricate anti friction bearings should be fresh and free from contamination Properly clean the grease inlet area of the motor to prevent grease contamination 12 8 Lu...

Страница 37: ...ure motor failure 12 10 Fan Rotor Cleanliness Once a year or if vibration develops clean the fan rotor surfaces so the unit runs smoothly To do this Lockout tag out all power sources remove the screen...

Страница 38: ...urned on 1 Check to make sure that all leads of your power source have voltage present If fan unit is not receiving power on all leads check for a blown fuse broken wire or loose connections 2 If powe...

Страница 39: ...in ordering and obtaining the correct parts Use the exploded view and tubular listing to exactly identify the required part All S3 AIR SYSTEMS Aeration Fans are supplied completely assembled with all...

Страница 40: ...XX 43 115452 XX Fan Housing 2 43 109961 43 114162 43 113539 43 113550 43 113950 Fan Rotor 3 7000 02 0875 7000 02 1125 7000 02 1125 7000 02 1125 7000 02 1125 Split Taper Bushing 4 43 114069 1 43 11407...

Страница 41: ...65 1 18 114066 1 18 114066 1 Bell Cone Inlet 5 0080 01 0026 0080 01 0026 0080 01 0026 0080 01 0026 Inlet Screen Ref Part Description 7 5 HP 1 PH 7 5 HP 3 PH 10 HP 1PH 10 HP 3 PH 1 18 114058 XX 18 1140...

Страница 42: ...3695 XX 18 113702 XX Fan Housing 2 18 113425 18 113684 18 113691 18 113698 18 113705 Fan Rotor 3 7000 03 1375 7000 03 1625 7000 03 1625 7001 05 1875 7001 05 1875 Split Taper Bushing 4 18 113912 1 18 1...

Страница 43: ...f Part Description 25HP 40HP 1 18 115415 XX 18 115428 XX Fan Housing 2 18 115422 18 115436 Fan Rotor 3 7000 03 1625 7001 05 1875 Split Taper Bushing 4 18 115418 1 18 115432 1 Bell Cone Inlet 5 0080 01...

Страница 44: ...Page 41 15 Wiring Diagrams 15 1 0312FC 3HP Full Centrifugal Fan 230 1PH 15 2 0512FC 5HP Full Centrifugal Fan 230 1PH...

Страница 45: ...Page 42 15 3 XX12FC 7 5 10HP Full Centrifugal Fan 230 1PH 15 4 XX32FC XXHP Full Centrifugal Fan 230 3PH...

Страница 46: ...Page 43 15 5 XX34FC XXHP Full Centrifugal Fan 460 480 3PH 15 6 XX36FC XXHP Full Centrifugal Fan 575 600 3PH...

Страница 47: ...Page 44 15 7 0312IL 03HP In Line Turbo Centrifugal Fan 230 1PH 15 8 0512IL 05HP In Line Turbo Centrifugal Fan 230 1PH...

Страница 48: ...Page 45 15 9 0712IL 7 5HP In Line Turbo Centrifugal Fan 230 1PH 15 10 XX12IL 10 15HP In Line Turbo Centrifugal Fan 230 1PH...

Страница 49: ...Page 46 15 11 XX32IL XXHP In Line Turbo Centrifugal Fan 230 3PH 15 12 XX34IL XXHP In Line Turbo Centrifugal Fan 460 480 3PH...

Страница 50: ...Page 47 15 13 XX36IL XXHP In Line Turbo Centrifugal Fan 575 600 3PH 15 14 XX12LS XXHP Low Speed Centrifugal Fan 230 1PH...

Страница 51: ...Page 48 15 15 XX34LS XXHP Low Speed Centrifugal Fan 230 3PH 15 16 XX34LS XXHP Low Speed Centrifugal Fan 460 480 3PH...

Страница 52: ...Page 49 15 17 XX34LS XXHP Low Speed Centrifugal Fan 575 600 3PH...

Страница 53: ...on Fan Discharge Bin Inlet S3 Part Number 18 O D 9 X 14 18 115500 1 18 O D 24 O D 18 115501 1 24 O D 9 X 14 18 115502 1 24 O D 12 X 17 18 115510 1 24 O D 18 O D 18 115503 1 24 O D 28 O D 18 115508 1 2...

Страница 54: ...Bin Inlet S3 Part Number 28 O D 24 O D 18 115509 1 9 X 14 18 O D 18 115504 1 9 X 14 24 O D 18 115505 1 9 X 14 28 O D 18 115506 1 9 X 14 12 X 17 18 115512 12 X 17 9 X 14 18 115507 12 X 17 18 O D 18 117...

Страница 55: ...AIR SYSTEMS or as prescribed by local provincial or State laws e Customer obtains the prior approval of S3 AIR SYSTEMS if field diagnostic inspection is required Travel and expenses must be pre approv...

Страница 56: ...mber ________________________ Delivery Date _________________________ Application ___________________________ Private Commercial Dealer Inspection Report ____ Shields Installed and Secured ____ Safety...

Страница 57: ......

Страница 58: ......

Отзывы: