Evaporative Air Cooler
10
Note: The pump protection also happens on water shortage when cool function been turned
on.
Picture 4-1 turn on VENT and COOL Picture 4-2 pump stop running (low water)
5. CLEAN
Drain function makes motor run by contraries to clean cooling pad, turn on the drain valve, drain the
dirty water out.
Press
button can turn on and turn off CLEAN unction.
Drain function running for 5 minutes, will stop automatically.
When draining, the water level will decline rapidly, so if the COOL function is still keep on, the pump
will pause automatically to protect pump, and running again when DRAIN stop a nd water filled enough.
Picture 5-1 turn on VENT, COOL and CLEAN
6. AUTO-CLEANING
When FAN and COOL functions work together for N hours(N can be set), air cooler will open the clean
function, drain out the dirty water in tank, and add clean water automatically.
The default of Auto- cleaning cycle is 08-hour.
Press
button to set up Auto-cleaning cycle , press
for 3 seconds, the Auto-cleaning cycle