General notes

Our “General Terms and Conditions for Business“ together with the “General Conditions for the Supply of Products and Services of the Electrical and 
Electronics Industry“ (ZVEI conditions) including supplementary clause “Extended Retention of Title“ apply as the exclusive terms and conditions.

In addition, the following points are to be observed:
–  These instructions must be read before installation and putting in operation and all notes provided therein are to be  regarded!
–  Devices must only be connected to safety extra-low voltage and under dead-voltage condition. To avoid damages and errors at the device (e.g. by voltage 

induction) shielded cables are to be used, laying parallel with current-carrying lines is to be avoided, and EMC directives are to be observed.

–  This device shall only be used for its intended purpose. Respective safety regulations issued by the VDE, the states, their  control authorities, the TÜV and 

the local energy supply company must be observed. The purchaser has to adhere to the building and safety regulations and has to prevent perils of any kind.

–  No warranties or liabilities will be assumed for defects and damages arising from improper use of this device.
–  Consequential damages caused by a fault in this device are excluded from warranty or liability.
–  These devices must be installed and commissioned by authorised specialists.
–  The technical data and connecting conditions of the mounting and operating instructions delivered together with the device are exclusively valid. Deviations 

from the catalogue representation are not explicitly mentioned and are possible in terms of technical progress and continuous improvement of our products.

–  In case of any modifications made by the user, all warranty claims are forfeited.
–  This device must not be installed close to heat sources (e.g. radiators) or be exposed to their heat flow.  

Direct sun irradiation or heat  irradiation by similar sources (powerful lamps, halogen spotlights) must absolutely be avoided.

–  Operating this device close to other devices that do not comply with EMC directives may influence functionality.
–  This device must not be used for monitoring applications, which serve the purpose of protecting persons against hazards or injury,  

or as an EMERGENCY STOP switch for systems or machinery, or for any other similar safety-relevant purposes.

–  Dimensions of enclosures or housing accessories may show slight tolerances on the specifications provided in these instructions.
–  Modifications of these records are not permitted.
–  In case of a complaint, only complete devices returned in original packing will be accepted.

Notes on commissioning: 

This device was calibrated, adjusted and tested under standardised conditions. When operating under deviating conditions, we recommend performing an 
initial manual adjustment on-site during commissioning and subsequently at regular intervals. 

Commissioning is mandatory and may only be performed by qualified personnel!  
These instructions must be read before installation and commissioning and all notes provided therein are to be regarded!

G  

Caution

You must ensure that the potentiometer is connected up correctly. Polarity reversal can cause a short circuit.

Devices are to be connected under dead-voltage condition. Devices 
must only be connected to safety extra-low voltage. Consequential 
damages caused by a fault in this device are excluded from warranty 
or liability. Installation of these devices must only be realized by au-
thorized qualified personnel. The technical data and connecting con-
ditions shown on the device labels and in the mounting and operating 
instructions delivered  together with the device are exclusively valid. 
Deviations from the catalogue representation are not explicitly men-
tioned and are possible in terms of technical progress and continu-
ous improvement of our products. In case of any modifications made 
by the user, all warranty claims are  forfeited. Operating this device 
close to other devices that do not comply with EMC directives may 
influence functionality. This device must not be used for monitoring 
applications, which solely serve the purpose of protecting persons 
against hazards or injury, or as an EMERGENCY STOP switch for sys-
tems or machinery, or for any other similar safety-relevant purposes.
Dimensions of enclosures or housing accessories may show slight 
tolerances on the specifications provided in these instructions. 
Modifications of these records are not permitted. 

In case of a complaint, only complete devices returned in original 
packing will be accepted.

Notes regarding mechanical mounting and attachment:
Mounting shall take place while observing all relevant regulations 
and standards applicable for the place of measurement (e.g. such as 
welding instructions, etc.). Particularly the following shall be regarded:
–  VDE  ⁄  VDI  directive  technical  temperature  measurements,   

measurement set - up for temperature measurements.

– The EMC directives must be adhered to. 
– It is imperative to avoid parallel laying of current-carrying lines.
– We recommend to use shielded cables with the shielding being 

 attached at one side to the DDC  ⁄  PLC.

Before mounting, make sure that the existing thermometer‘s techni-
cal parameters comply with the actual conditions at the place of 
 utilization, in particular in respect of:
– Measuring range 
– Permissible maximum pressure, flow velocity 
– Installation length, tube dimensions
– Oscillations, vibrations, shocks are to be avoided (< 0.5 g)
Attention! In any case, please observe the mechanical and thermal  
load limits of protective tubes according to DIN 43763 respectively  
according to specific S+S standards!

G  

Mounting and Installation

Содержание 1101-40A0-1003-000

Страница 1: ...nsducers on wall RTF1 Nerezová ocel stainless steel RTF1 Domat Control System s r o U Panasonicu 376 530 06 Pardubice Stare Civice CZ Česká republika Tel 420 461 100 823 Fax 420 226 013 092 info domat cz www domat int com Gratulujeme Zakoupili jste produkt německé kvality Congratulations You have bought a German quality product 6000 3090 0000 1XXD1 30900 2020 D1 V105 04 2020 ...

Страница 2: ...THERMASGARD RTF1 G Rozměry Kryt Baldur1 Dimensional drawing Housing Baldur1 T K ø 6 0 85 85 27 2 28 9 Rozměry Kryt nerezové oceli Dimensional drawing Housing stainless steel 25 ø 6 0 75 72 75 72 ...

Страница 3: ...y uprostřed zařízení zatlačte směrem dolů a mírně nadzdvihněte spodní část krytu Odejměte vrchní část krytu vpřed To open the housing set a screwdriver 2 0 in the groove at centre press down and lift up the bottom frame slightly Pull top cover forward and hold it Kryt Baldur Housing ...

Страница 4: ... ocel V2A 1 4301 Montáž Na stěnu nebo na krabici pod omítku Ø 55 mm základna se 4 otvory pro montáž svisle nebo vodorovně instalované krabičky pod omítku se vstupy kabelů vzadu s předem určeným bodem zlomu pro vstup kabelu v horní dolní části Elektrické připojení 0 14 1 5 mm pomocí šroubových svorek zajištěno proti kroucení pouze na nízké napětí max 24 V DC Přípustná vzdušná vlhkost max 90 r H bez...

Страница 5: ...y Připojovací části se nachází v připojovací hlavici Standardní připojení ponorných čidel je pomocí G závitu pro kanálová čidla je připojení zajištěno montážní přírubou Pokud je jímkové čidlo umístěno v prodlužovací trubici je jeho teplotní rozsah obvykle poněkud větší jelikož stoupající teplo nemůže proudit přímo do připojovací hlavice Dbejte na to zejména při instalaci čidla U vestavěných senzor...

Страница 6: ...ny Reklamace bude uznána pouze u zařízení vrácených v kompletním originálním balení Pokyny k uvádění do provozu Přístroj byl kalibrován nastaven a testován za normovaných podmínek Při provozu za jiných podmínek doporučujeme ruční justování na místě instalace při uvádění do provozu a poté v pravidelných intervalech Uváděni do provozu je nutnou součástí instalace a musí být provedeno odborným person...

Страница 7: ......

Страница 8: ...m Baldur 1 Standard 98 x 98 x 33 mm Baldur 2 75 x 75 x 25 mm stainless steel V2A 1 4301 Installation wall mounting or on in wall flush box Ø 55 mm base with 4 hole for mounting on vertically or horizontally installed in wall flush boxes for cable entry from the back with predetermined breaking point for on wall cable entry from top bottom in case of plain on wall installation Electrical connection...

Страница 9: ...tinguished into temperature sensors with interchangeable measuring insert and without interchangeable measuring insert Connection parts are placed inside a connecting head Standard process connection for immersion sensors is a pipe thread sizes in inches and a mounting flange for duct sensors However it may be designed differently When a built in sensor has a neck tube the application range is usu...

Страница 10: ...n operating under deviating conditions we recommend performing an initial manual adjustment on site during commissioning and subsequently at regular intervals Commissioning is mandatory and may only be performed by qualified personnel These instructions must be read before installation and commissioning and all notes provided therein are to be regarded G Caution You must ensure that the potentiome...

Страница 11: ...zchybnou kvalitu zaručujeme v rámci našich Všeobecných obchodních podmínek Subject to errors and technical changes All statements and data herein represent our best knowledge at date of publication They are only meant to inform about our products and their application potential but do not imply any warranty as to certain product characteristics Since the devices are used under a wide range of diff...

Страница 12: ...461 1760 1625 4 3552 3817 3930 120 130 149 8 1498 1833 3676 4008 130 140 153 6 1536 1909 3802 4166 140 150 157 3 1573 1987 3929 4280 150 NTC 1 8 kOhm NTC 2 2 kOhm NTC 3 kOhm NTC 5 kOhm NTC 10 kOhm NTC 10 kPRE NTC 20 kOhm NTC 50 kOhm C Ω Ω Ω Ω Ω Ω Ω Ω C 50 50 40 39073 806800 2017000 40 30 22301 27886 53093 88488 175785 135200 413400 1033500 30 20 13196 16502 29125 48541 96597 78910 220600 551500 20...

Отзывы: