7
P o w e r C o n n e c t i o n w i t h G F C I :
To wire the WPC-1 with the use of a GFCI, punch out the GFCI knockout on the side of the
WPC-1 enclosure.
Install an outdoor rated GFCI. Using
COPPER
wire only, 12 gauge minimum, connect the
GFCI from the
LOAD
side to the
HOT
terminal on the POWER INPUT of the WPC-1.
Connect the
NEUTRAL
from the
LOAD
side of the GFCI to the
NEUTRAL
terminal from
the WPC-1.
Connect the
GROUND
of the GFCI to the EQUIP. GND. bar.
Wire the
HOT
from the GFCI’s
LINE
side to the 20Amp circuit breaker in the main breaker panel as
discussed earlier.
Connect the
NEUTRAL
from the GFCI’s
LINE
side to the house common.
From the GFCI’s
LINE
side, connect a wire from the
HOT
to the Timeclocks
T/C POWER
terminal.
From the
NEUTRAL
of the
LINE
side on the GFCI, connect to the
T/C NEUTRAL
on the terminal block.
NOTE:
Do not connect the Timeclock Inputs to the
LOAD
side of the GFCI.
NEUTRAL
LOAD SIDE
HOT
LOAD SIDE
GFCI
TO NEUTRAL BAR
HOT LINE SIDE
T/C NEUTRAL
T/C POWER
GROUND
120VAC 20 AMP
CIRCUIT BREAKER
Содержание WPC1 Series