WPC1-XXXX-T

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions

Read these instructions in their entirety before performing any installation work

FOR USE WITH POOL AND SPA PRODUCTS

4008814

ETL LISTED

Conforms to UL STD 379;

Certified to CSA STD C22.2 #218.1

79-15223-00 REV C1

Содержание WPC1 Series

Страница 1: ...AC 60Hz applications Installation Instructions Read these instructions in their entirety before performing any installation work FOR USE WITH POOL AND SPA PRODUCTS 4008814 ETL LISTED Conforms to UL ST...

Страница 2: ...2...

Страница 3: ...r lighting use 6 Power Connection with GFCI 7 Hooking up Low Voltage Lights to Circuit 1 8 PUMP CONNECTIONS 9 Connecting A 240VAC Single Speed Pump 9 External Magnetic Antenna Mounting 10 OPERATING IN...

Страница 4: ...12VAC 30 watt transformer Optional Accessory Part Description Not shown FP 1 2 Temperature Freeze Device Not shown PLX ANTKT L 15 meter magnetic mount antenna Kit ELECTRICAL RATINGS Do not exceed the...

Страница 5: ...s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Страница 6: ...e power connections remove inches of insulation from wire ends Insert the bare end of wires under the pressure plate of terminals Power Input HOT Use in flat head screwdriver to tighten terminal screw...

Страница 7: ...the GROUND of the GFCI to the EQUIP GND bar Wire the HOT from the GFCI s LINE side to the 20Amp circuit breaker in the main breaker panel as discussed earlier Connect the NEUTRAL from the GFCI s LINE...

Страница 8: ...nvenient location to store service loop cable Use appropriate wire from the separate 12VAC output block to supply Low Voltage power from the WPC1 XXXX T to the approved Pull Junction or Bell Box Use t...

Страница 9: ...eaker for each pump if this control box is equipped with optional pump relays Using an appropriately sized copper wires connect to the outer contacts of the JQX relays of the appropriate pumps as show...

Страница 10: ...the antenna into a clear receiving zone While not required best range performance is found when the remote and the antenna are within line of sight and 100 or less NOTE The remote function of this de...

Страница 11: ...ce the time and time of operation has been set ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below To turn off timers automatic functions set the Ti...

Страница 12: ...l be disabled To re enable wireless remote operation flip the toggle switch back to the REMOTE position NOTE If a device turns ON when the toggle switch is set to the REMOTE position turn the wireless...

Страница 13: ...HANGE to toggle on and off the power of Zone 2 on the WPC panel Color Changing Operation To change LED pool light colors simply toggle the power OFF then ON using the button marked 1 or 2 within 1 sec...

Страница 14: ...BK R BR BK 6 7 5 3 BK BR W R 1 2 8 4 BK W BK W BL BL CRIMP CONNECTORS 120V LINE NEUTRAL NEUTRAL CIRCUIT 2 12 VAC 12 VAC TC POWER TC NEUTRAL BK CIRCUIT 1 FOR USE ON WPC AUXILIARY RELAY KIT FOR TEMPERA...

Страница 15: ...WITCH 2 5 8 2 6 3 9 1 6 4 1 7 2 Y BK BR R 7 3 5 4 8 W O BK BK SWITCH 1 REMOTE ON COM ON COM M COM NO TIMER WARRANTY INFORMATION For Lighting product warranty information and details please visit our w...

Страница 16: ...C P O Box 400 Canby OR 97013 P 503 266 2231 TF 800 824 4387 srsmith com 2018 S R Smith All rights reserved 79 15223 00 REV C1 Questions Contact One of Our Dedicated Lighting Specialists 1 800 824 4387...