background image

06-901

 

© S.R. Smith LLC 2008 

DEC09

 

 
 

WetDek 

 
 

 
 
 
 
 
 

 
 

 

 

 

 

 
 

 

 

 

CORPORATE HEADQUARTERS 

WESTERN SALES AND MANUFACTURING PLANT 

P.O. Box 400 

 1017 SW Berg Parkway 

Canby, Oregon 97013 

(503) 266-2231 

 Fax (503) 266-4334 

www.srsmith.com 

INSTALLATION INSTRUCTIONS 

AND OWNER’S MANUAL 

Содержание WetDek

Страница 1: ... 2008 DEC09 WetDek CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P O Box 400 1017 SW Berg Parkway Canby Oregon 97013 503 266 2231 Fax 503 266 4334 www srsmith com INSTALLATION INSTRUCTIONS AND OWNER S MANUAL ...

Страница 2: ...f metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG solid copper conductor that is bonded to the control box Do not permit any electrical appliance such as a light telephone radio or television within 5 feet 1 5m of a WetDek EXTREME CAUTION adult supervision required during use Do not leave children unattended around the WetDek To avoid accidents and injury insure...

Страница 3: ...1 30013 8 Drain w 6 ABS Hub X X 7 1 30014 6 ABS to 4 PVC Converter X 8 1 30001 HP Pump X 9 1 30002 25sf Filter Housing Chlorinator X 10 1 30004 150 Gallon Reservoir w Fittings ITEMS NEEDED FOR INSTALLATION 1 PVC Pipe 4 1 5 and 1 length varies 8 Level 2 PVC Fittings Varies 9 PVC Saw 3 PVC Primer 10 Wire Cutters 4 PVC Glue 11 Tape Measure 5 8 AWG Copper Bonding Wire 12 Valve Box optional 6 16 AWG El...

Страница 4: ...p of the reservoir must be located at least 6 inches lower than the drain This means that the reservoir should either be buried or placed downhill from the WetDek surface The maximum change in height from the WetDek surface to the standing level of water in the reservoir is 5 feet if more height is required contact S R Smith DO NOT HOOK THE WETDEK UP TO A SUCTION RETURN 1 The 150 Gallon Reservoir ...

Страница 5: ...AquaDirector Controller 1 is rated as a NEMA 3R enclosure which allows it to be placed indoors or outdoors 13 The valve manifold for the Stand Alone version should be setup as shown in FIGURE 4 14 Each of the 1 Manifold Tees 4 should be attached to one of the 1 HPV Valves 3 This is done by threading the male portion of the manifold tee to the female inlet side of the valve It is important to insur...

Страница 6: ... 6 above the surface of the water in the adjacent pool This will help to eliminate puddles from forming on the surface The drain should run directly to the pool and MUST NEVER BE CONNECTED TO A SUCTION RETURN If bulkhead fittings are used the 4 drain line can be split into two 1 lines that run into the pool 5 For existing pools where bulkhead fittings would be difficult it is possible to hook up t...

Страница 7: ... edge of the pad to the drain 20 The nozzles must be at least two feet from the edge of the pad to prevent overspray The nozzles have adjustable ball valves that can be aimed in any direction up to 60 degrees 21 The distance from the pump to the valves and from the valves to the nozzles is important Depending on the distance the diameter of pipe needs to vary for optimal performance TABLE 1 and FI...

Страница 8: ... separates each zone by measured increments 2 SPIGOT FOR STAND ALONE A spigot can be incorporated in the stand alone version of the WetDek to allow for draining the reservoir as shown in FIGURE 9 this spigot should be located between the pump 8 and filter chlorinator 9 The spigot must be easily accessible to allow for connection to a hose No spigot is required for the poolside version because the ...

Страница 9: ...nifold needs to be moved closer to the pad because of distance requirements maximum distance from the valve manifold to furthest nozzle is 50 it is recommended that the valves be buried and placed in a standard green valve box used for sprinkler systems This can be used for either the Stand Alone or Poolside versions WETDEK AQUADIRECTOR CONTROLLER INSTALLATION The WetDek System Controller requires...

Страница 10: ...re that runs from the contactor to the terminal block as shown in FIGURE 12 This wire needs to be moved to the terminal that reads 240V on the terminal block This should be done before any other wiring is attached to the controller The WetDek AquaDirector can be hooked up to a pool control system such as the Easy Touch or Aqua Link This is accomplished by powering the AquaDirector from one of the ...

Страница 11: ... be divided evenly amongst the three zones Two nozzles per zone for a 6 nozzle kit three nozzles per zone for a 9 nozzle kit and four nozzles per zone for a 12 nozzle kit Nozzles can be placed anywhere on the loop to allow for maximum customization PAD SIZE A B C 11 Diameter 6 Nozzles 84 48 24 13 Diameter 9 Nozzles 108 72 36 15 Diameter 12 Nozzles 132 96 48 TABLE 2 All dimensions given in inches F...

Страница 12: ...12 PAD SIZE A B 12 x 12 6 Nozzles 24 84 14 x 14 9 Nozzles 36 108 16 x 16 12 Nozzles 48 132 TABLE 3 All dimensions given in inches FIGURE 14 ...

Страница 13: ...13 PAD SIZE A B C 12 x 8 6 Nozzles 96 6 24 14 x 10 9 Nozzles 120 12 36 16 x 12 12 Nozzles 144 18 48 TABLE 4 All dimensions given in inches FIGURE 15 ...

Страница 14: ... the controller to Pentair Jandy and Hayward controllers Just one power cord going from the SRS box to the controller It will only use one relay on the automation system and will only control turning the box on off 2 What size pump is required for the pool kit version The builder should know the capabilities of the preexisting equipment The size of the pump and filter will always be determined by ...

Страница 15: ...pump does not remove should be sucked out with a wet dry vacuum FILTER MAINTENENCE At least once a month or more often based on environmental conditions check and clean the skimmer basket of the pump to ensure proper flow Remove leaves foreign matter and debris when present It is also very important to maintain your WetDek filter cartridge clean and free of particles that can obstruct water flow A...

Отзывы: