S.P.L. HF-400 Скачать руководство пользователя страница 19

 

S.P.L.

 

HF-400 User manual 

 
 

19 

6 Measurement  

 

 

Picture 6. 1 

 

 

Picture 6. 2 

 

 

Содержание HF-400

Страница 1: ...relevant standards it is important to use the versions with the most recent date of issue We reserve the right to make any changes to the information in this manual without prior notice S P L Elektro...

Страница 2: ...gef hrlicher Stoffe in Elektro und Elektronikger ten RoHS Richtlinie Richtlinie 2014 30 EU des Europ ischen Parlaments und des Rates vom 26 Februar 2014 Elektromagnetische Vertr glichkeit Angewendete...

Страница 3: ...SUREMENT AT ELECTRO SURGERY UNITS 9 4 2 POWER MEASUREMENT AT HF ELECTROSURGICAL DEVICES 10 4 3 LEAKAGE CURRENT MEASUREMENT AT HF ELECTROSURGICAL DEVICES 11 4 4 FUNDAMENTAL MEASUREMENT SETUP 11 4 5 NEU...

Страница 4: ...the different functions of the device could be activated The last choice you made will remain also after switching the device off so that you do not need to select everything again In the stand alone...

Страница 5: ...mA Discrimination 0 1 mA or HF output power 0 500 Watt Crest Faktor V2 1 10 at 1000 mA HF leakage current 0 250 mA Discrimination 0 1 mA Neutral electrode test 0 1000 Ohm Range 0 3 10 MHz Measuring p...

Страница 6: ...ied measuring accuracy refers to the measuring element Technical modifications and errors reserved 05 2016 2 2 Further information Keyboard 6 key foil keyboard Display 4 x 20 char LCD B W Display Inte...

Страница 7: ...ks described All warning labels and symbols on the HF 400 are explained in the following general warning signs IEC 61010 1 2011 terminal for earth IEC 61010 1 2011 replaced HINT Labels and texts on th...

Страница 8: ...fixed 200 ohms resistance The 5 th Safety laboratory socket serves for the additional contacting of the equipotential connection of the HF electro surgery devices to the measuring instrument The norm...

Страница 9: ...ndent as it is shown in the alternate circuit diagram on the internal resistor Ri of the surgical device and from the neutral voltage U0 from the HF generator within the HF surgical device 2 I U R R L...

Страница 10: ...current resulting from this HF voltage produces a HF voltage over a special current transformer proportional to the HF current This HF voltage is loaded by a voltage divider and the signal resulting i...

Страница 11: ...escription test adapter could be used for the connection with another testing device e g modular test system GS X With the power switch the HF 400 is turned on After switching on the self check of the...

Страница 12: ...nd serves as a characteristic value for the assessment of the waveform of the RF signal High Crest factors mean a high proportion of harmonics A sinusoidal alternating current has for example a crest...

Страница 13: ...il keys The arrow keys serve the selection in the menu or to the parameter selection The ENTER key serves as a start button With the ESC key the respective program can be broken off The latest selecti...

Страница 14: ...nt S P L E l e k t r o n i k H 2 0 V 1 0 0 1 2 3 4 0 After a short time the main menu appears with following items H F 4 0 0 H F p o w e r H F l e a k c u r r S e t u p H F 4 0 0 H F U R M S H F I R M...

Страница 15: ...ith arrow keys UP and DOWN you can change the selected resistor value in steps of 25 Ohm With the ENTER key you start the measurement With the ESC key you will stop and leave the measurement If you pr...

Страница 16: ...arrow keys UP and DOWN you can change the selected resistor value in steps of 25 Ohm With the ENTER key you start the measurement With the ESC key you will stop and leave the measurement If you press...

Страница 17: ...ou can set the real time clock H F 4 0 0 t i m e d a t e 0 1 0 4 2 0 0 8 1 4 0 8 2 6 H F 4 0 0 c h o o s e l a n g u a g e d e u t s c h With these settings you can choose between following languages...

Страница 18: ...nterface with a special PC Software Function steps from HF 400 SPL551 HF output power SPL552 HF leakage current SPL553 HF U RMS SPL554 HF I RMS SPL555 HF P M3 SPL556 V2 HF U Peak SPL557 V2 HF I Peak S...

Страница 19: ...S P L HF 400 User manual 19 6 Measurement Picture 6 1 Picture 6 2...

Страница 20: ...S P L HF 400 User manual 20 Picture 6 3 Picture 6 4...

Страница 21: ...S P L HF 400 User manual 21 Picture 6 5 Picture 6 6...

Страница 22: ...S P L HF 400 User manual 22 Picture 6 7 Picture 6 8...

Страница 23: ...S P L HF 400 User manual 23 Picture 6 9 Picture 6 10...

Страница 24: ...S P L HF 400 User manual 24 Picture 6 11 Picture 6 12...

Страница 25: ...S P L HF 400 User manual 25 Picture 6 13 Picture 6 14...

Страница 26: ...S P L HF 400 User manual 26 Picture 6 15...

Страница 27: ...on By an update of the firmware for example changes in standards expansions of the function of the devices etc are automatically integrated By the implemented inspection and calibration the validity i...

Отзывы: