11
Where:
OFF = the LED is off
ON = the LED is steady
BLK = the LED is blinking
Note (*): The sequence of phases and relative messages varies according to the curve.
ERROR MESSAGES ON THE DISPLAY
In the event of anomalies, the following error codes may be displayed.
ERROR CODE
PROBLEM
SOLUTIONS
Srt:IB > IBmax
The output current has
exceeded circuits the
nominal current value by
more than 10%.
Make sure there are no short cicuits on the battery
or the battery cables or there is an active load
on the battery that draws more current than the
charger can provide.
E01: Open Circuit
The current suddenly went
to zero unexpectedly.
Check the connection of the clamps to the battery
and check the voltage of the battery elements to
make sure that there are no elements in an open
circuit condition. The charger starts again after 5
seconds.
E02: Temperature
The internal thermal
sensor has detected high
temperature.
Use the charger in a well-ventilated area.
E03: Timer
The safety timer of one
of the phases has been
activated.
Make sure that a suitable charging current has
been set for the battery capacity and that the
selected voltage corresponds to the voltage of
the battery. Also, make sure that there are no
elements in short circuit and that the battery is not
sulphated.
Start
Auto-start execution
OFF
OFF
OFF
F1
Phase 1: Initial charge at constant current ON
OFF
OFF
F2
Phase 2: Final charge at constant voltage ON
OFF
OFF
F3_I (*)
Phase 3: Final charge at constant current OFF
ON
OFF
F3_U (*)
Phase 3: Final charge at constant voltage OFF
ON
OFF
F4
Charging complete
OFF
OFF
ON
LED MESSAGES DISPLAYED
Ref.
Messages reported
DL3 LED
(Red)
DL2 LED
(Yellow)
DL1 LED
(Green)