9)  Do not use the battery charger outdoors.

10) Do not expose the battery charger to rain, water splashes or steam.

11) Do not install the battery charger in caravans and / or similar vehicles.

12) Do not install the battery charger near any heat sources or in areas with high 

concentrations of dust.

13) 

Do not install the battery charger near any potential sources of flammable 

material, for example methane gas pipes or fuel depots (petrol, kerosene, ...).

14) 

Do not place and/or fit the battery charger onto surfaces manufactured out 

of combustible materials, like wooden shelves or walls.

BATTERIES

15) 

Follow the specific safety instructions provided by the battery manufacturer 

carefully, for example, whether to remove cell caps during charging and the 

recommended charge rates.

16) Working in the vicinity of a lead-acid battery is dangerous, as batteries 

generate explosive gases during charging. Therefore, smoking and/or 

generating open flames and/or sparks must be avoided.

17) Never charge a frozen battery.

18) 

Batteries must be charged in specific, well-ventilated areas.

19) In order to reduce risk of injury only charge Lead–Acid, GEL or AGM type, 

Lithium Polymer or Lithium-Ion batteries. Do not charge other types of 

rechargeable or non-rechargeable batteries as they could explode causing 

damage and/or injury.

FURTHER SPECIFICATIONS FOR LITHIUM BATTERIES

20) 

In order to charge Lithium Polymer and Lithium-Ion batteries, a BMS (Battery 

Management System) must always be used, comprising an active and 

passive safety system, in compliance with safety regulations in force.

21) The possibility of the BMS acting directly on the battery charger operation 

during cell balancing phases rules out, for any reason whatsoever, that the 

battery charger is held directly responsible should damage caused to the 

battery, or even a fire or an explosion, be due to an error in the BMS software.

22) The faculty offered by the materials produced by S.P.E. ELETTRONICA 

INDUSTRIALE to select different levels of voltage for charging, is entrusted 

to the control and supervision of the end user and S.P.E. ELETTRONICA 

INDUSTRIALE is not liable for any consequences resulting from the selection 

of the incorrect level of voltage. If in doubt, the user should ask a qualified 

professional for clarification.

Содержание 24-CBHF2M-3625FLEX

Страница 1: ...User Manual Important Safety Installation and Operation Instructions Attention Read the user manual carefully before using the battery charger High Frequency Battery Charger Model 24 CBHF2M 3625FLEX...

Страница 2: ...g label must be visible after installation CHILDREN 6 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of exp...

Страница 3: ...ific well ventilated areas 19 In order to reduce risk of injury only charge Lead Acid GEL or AGM type Lithium Polymer or Lithium Ion batteries Do not charge other types of rechargeable or non recharge...

Страница 4: ...is the task of the BMS and not of the battery charger CHECKING CABLES GRID EARTHING 26 Do not transport the battery charger by pulling on the cables as they could be damaged Use the handles on the bat...

Страница 5: ...olymer or Lithium Ion batteries is correct for the type of battery to be charged 34 We recommend unplugging the battery charger from the mains supply before connecting and disconnecting batteries 35 D...

Страница 6: ...to 50 C from 4 F to 122 F Relative humidity 0 80 up to 50 C 0 80 up to 122 F Operating temperature from 0 C to 45 C from 32 F to 113 F Programmable Charging Profiles are INDEX CURVE 1 MK AGM 2 Acd Wet...

Страница 7: ...ON I BATTERY CAPACITY RANGE L PRODUCT CERTIFICATION STAMPS M NUMBER OF CELLS BATTERY CHARGER IDENTIFICATION LABEL A CUSTOMER PART NUMBER B PART NUMBER C MODEL D INPUT VOLTAGE AND MAINS ABSORPTION E OU...

Страница 8: ...profile is displayed when button is pressed To enter the charging parameter menu see CHARGING SETTINGS OPERATION Connect the AC power cable supplied with the battery charger to the charger Connect the...

Страница 9: ...process If the battery is not connected to the charger the display shows No Battery This message remains on the display if the test is unsuccessful The same message is displayed in the case of Reverse...

Страница 10: ...cycle is also indicated by three LEDs DL3 display LED 3 RED DL2 display LED 2 YELLOW DL1 display LED 1 GREEN RED YELLOW GREEN CHARGING SETTINGS To set the charger in relation to the battery that need...

Страница 11: ...ype of curve Voltage and Current SELECT Press again to confirm the set value the red DL3 LED will turn off SELECT After setting the values exit the setup menu by selecting Programming Save and Exit an...

Страница 12: ...re that there are no elements in an open circuit condition The charger starts again after 5 seconds E02 Temperature The internal thermal sensor has detected high temperature Use the charger in a well...

Страница 13: ...rrent BLK OFF OFF No Battery OFF BLK OFF Inversion of polarity OFF BLK OFF Battery in Short Circuit OFF BLK OFF Incorrect Battery Voltage OFF BLK OFF Over temperature error BLK OFF OFF Corrupted charg...

Страница 14: ...13...

Страница 15: ...ontact Flight Systems Industrial Products FSIP 1015 HARRISBURG PIKE CARLISLE PA 17013 WEBSITE www shop fsip biz PHONE 1 800 333 1194 Or Flight Systems Industrial Products FSIP MIDWEST BRANCH 80 S FAIR...

Страница 16: ...15 NOTES COMMENTS...

Отзывы: