S-Energy

 

PV Module Installation Manual

1)

2)

3)

4)

5)

6)

Please make sure that installed module wire distribution is correct, and insulation and waterproof performance of 

connect part is suitably installed. 

Check if there are any scratches on the frame and front surface of the glass.

[The scratch may lead oxidation and reduce the strength.]

Regularly clean the module with water, and if the module is not cleaned with water, request to the manufacturer.

[Regular cleaning can significantly improve the output capacity.]

The front surface of glass is specially treated, so do not apply any abrasive cleaning product or chemicals.

Periodic inspection should be performed only by qualified personnel with protective equipment.

To avoid shade by the vegetation environment, regular weeding is needed.

Please read this instruction before installing PV module.

Caution before Installation

Caution when Installed

4.

5.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

15)

16)

17)

18)

The installation of PV module should be performed by qualified personnel only.

When installing PV module, you should wear protective equipment. [electric shock or falling accident risk.]

When installing PV module, do not step up onto the PV module or place the object on it.

After installation, qualified person shall check whether it operates properly or not.

Disassembling or replacing of the PV module part is not allowed without permission by manufacturer, and if you disassemble 

or replace anything, please inform the PV module manufacturer.

When disassembling or replacing the part with manufacture’s permission, it should be performed by qualified person only, 

and use the certified accessories.

All installation work most be done to meet the local applicable standards, such as the recent National Electrical Code or 

National Electrical Standards.

When the PV module is damaged or stopped, anyone, even who has useful knowledge for the PV module, should not 

approach to the PV module. Touch or approach may cause serious injury, in which case manufacturer is not responsible for 

the damage therefrom.

PV module’s orientation shall be at equator direction, and be installed at the same angle as the latitude of the installation 

location for the optimal generation performance. If it is installed at a different angle or direction, it may adversely affect an annual 

generation capacity. In case of horizontal installation, 

S-Energy

 recommends regular cleaning to remove dust on the surface.

PV module generates the voltage even without load connection. So, be careful for sparks especially when assembling /

disassembling PV module.

PV module is intended to be installed on the ground or building. 

If you need to install on the vehicle(car, train, etc.) or ship, please request special modules.

Snow, water, dust, or other foreign substance on the surface may increase reflection of the light and eventually reduce the 

PV module’s output. [Regular cleaning of module surface can improve performance.]

Standard specifications was measured at STC rating conditions, temperatures can get very effective in increasing power 

generation is low.

Before installation, modules should be stored under packing condition.

Irrespective of module connection, contacting current carrying part may cause a burn or fatal electrical shock from sparks.

The shading of the front surface of the module can cause the module degradation by fire or reduce its lifecycle.

When working with the PV module wire, connect the wire with a hanger to avoid contact on the roof or ground.

Potential

 

Induced

 

Degradation

 

[PID]

 

may

 

be

 

caused

 

by

 

ambient

 

high

 

temperature,

 

humidity,

 

and

 

high

 

system

 

voltage.

 

S-

Energy's

 

PV

 

module

 

equipped

 

with

 

Enhanced

 

PID

 

module

 

can

 

endure

 

these

 

degradation,

 

but

 

a

 

long

 

term

 

exposure

 

may

 

also

 

cause

 

PID.

 

To

 

competely

 

prevent

 

PID,

 

 

trans

 

inverter

 

and

 

Nagative

 

GND

 

should

 

be

 

connected

 

to

 

the

 

(-)

 

GND

 

with

 

the

 

module

 

frame.

Do not use or install broken modules; Failure to comply may result in fire, electric shock, and injury.

19)

Содержание SC Series

Страница 1: ...EN ver 1 0_2019 Copyright 2019 S Energy all rights reserved INSTALLATION GUIDE SC SERIES 1 000V ENHANCED PID ENVIRONMENT RESISTANCE MECHANICAL LOAD 5 400 Pa HAIL IMPACT TEST 25 m s...

Страница 2: ...S Energy PV Module Installation Manual 0 0 2019 09 23 1st edition Rev history...

Страница 3: ...onsiderations 4 Caution before Installation 5 Caution when Installed 6 Electrical Installation 7 Grounding Method 8 Mechanical Installation 9 Maintenance 10 Cleaning Instructions 11 Detailed Module Sp...

Страница 4: ...hall be based on this manual and the actual installation use operation and maintenance should be performed by qualified personnel with electrical license For the detailed quality warranty policy of th...

Страница 5: ...y or causes risks to the whole system Install when the weather is clear Do not install when snowy rainy and windy days Do not install where water remains on the ground All surfaces and corners are fra...

Страница 6: ...use performance degradation due to solar cell degradation Do not touch or give shocks to the Junction box as well as front and rear surface of module and do not remove the label Prohibited taking J bo...

Страница 7: ...wledge for the PV module should not approach to the PV module Touch or approach may cause serious injury in which case manufacturer is not responsible for the damage therefrom PV module s orientation...

Страница 8: ...the module with hardware that has been tested and evaluated with the module under this standard or by a field inspection certifying that the installed module complies with the requirements of UL 1703...

Страница 9: ...may be used for grounding connections in accordance with the instructions provided with the module The grounding clip assembly consists of a slider base and self captivating thread cutting screw or 1...

Страница 10: ...of module installation site is limited by the minimum and maximum temperature as shown below Considerations when temperature rises output is reduced due to characteristics of the module Maximum opera...

Страница 11: ...frame hole passed a mechanical load test item in accordance with the IEC 61215 and UL 1703 standard and S Energy Co Ltd recommends the following method of installing a frame hole As described in fig...

Страница 12: ...iron glass and the ARC glass to minimize with light reflection Cleaning time is taking into account the thermal shock and power generation please proceed early in the morning and cloudy weather Clean...

Страница 13: ...97 V 18 96 325 W 33 60 V 9 68 A 325 W 10 11 A 41 11 V 19 26 40 to 85 1 000V A 20 0 3 Rated Power Pmax Voltage at Pmax Vmp Current at Pmax Imp Warranted Minimum Pmax Short Circuit Current Isc Open Cir...

Страница 14: ...S Energy PV Module Installation Manual 1 Hole installation method Installation Instructions 12 11 2 Location and method of clamp installation...

Страница 15: ...the frame Be sure to avoid shadowing effects from the module clamps When choosing this type of clamp mounting method use at least four clamps on each module two clamps should be attached on each long...

Страница 16: ...ergy com en H E A D O F F I C E C O N T A C T Fl3 MiraeAsset Tower 20 Pangyoyeok ro 241 beon gil Bundang gu Seongnam Gyeonggi do 13494 Republic of KOREA Tel 82 70 4339 7100 Fax 82 70 4339 7199 E mail...

Отзывы: