S-Energy SC Series Скачать руководство пользователя страница 6

0

3

S-Energy

 

PV Module Installation Manual

ENVIRONMENTAL CONSIDERATIONS

1)

2)

The shading of the front surface is the main cause of hot spot or 
performance reduction of power generation. 
The ground should have well drained soil. 

CAUTION

CAUTION

Do not scratch by a sharp tool on the module 
frame and surface. Abrasion of the coated 
surface may lead to oxidize frames or reduce 
their strength.The scratch of the surface may 
be the main cause of the module output 
degradation and decrease in strength.

The front surface of the module shall not be 
exposed to sunlight artificially.
[It can cause performance degradation due 
to solar cell degradation.] 

Do not touch or give shocks to the Junction 
box as well as front and rear surface of 
module, and do not remove the label.

Prohibited taking J-box cable when you 
handle the modules.
[Resulting in electrical disconnection.]

Prohibited connecting diagonally Male & 
Female  when electrical [connector] connecting.
[Resulting in poor contact.]

Cable outer diameter of 8mm/ Recommended 
by more than 48mm radius of curvature.
[Cable minimum bend radius is more than 
6 times the cable diameter when wiring.]

Cable wiring securely fixed to prevent shaking 
in the wind with cable tie.
[However, consider summer/winter thermal 
expansion/contraction.] 

Do not touch with wet hands or equipment, 
which can result in electric shock.

Environmental Considerations

3.

Содержание SC Series

Страница 1: ...EN ver 1 0_2019 Copyright 2019 S Energy all rights reserved INSTALLATION GUIDE SC SERIES 1 000V ENHANCED PID ENVIRONMENT RESISTANCE MECHANICAL LOAD 5 400 Pa HAIL IMPACT TEST 25 m s...

Страница 2: ...S Energy PV Module Installation Manual 0 0 2019 09 23 1st edition Rev history...

Страница 3: ...onsiderations 4 Caution before Installation 5 Caution when Installed 6 Electrical Installation 7 Grounding Method 8 Mechanical Installation 9 Maintenance 10 Cleaning Instructions 11 Detailed Module Sp...

Страница 4: ...hall be based on this manual and the actual installation use operation and maintenance should be performed by qualified personnel with electrical license For the detailed quality warranty policy of th...

Страница 5: ...y or causes risks to the whole system Install when the weather is clear Do not install when snowy rainy and windy days Do not install where water remains on the ground All surfaces and corners are fra...

Страница 6: ...use performance degradation due to solar cell degradation Do not touch or give shocks to the Junction box as well as front and rear surface of module and do not remove the label Prohibited taking J bo...

Страница 7: ...wledge for the PV module should not approach to the PV module Touch or approach may cause serious injury in which case manufacturer is not responsible for the damage therefrom PV module s orientation...

Страница 8: ...the module with hardware that has been tested and evaluated with the module under this standard or by a field inspection certifying that the installed module complies with the requirements of UL 1703...

Страница 9: ...may be used for grounding connections in accordance with the instructions provided with the module The grounding clip assembly consists of a slider base and self captivating thread cutting screw or 1...

Страница 10: ...of module installation site is limited by the minimum and maximum temperature as shown below Considerations when temperature rises output is reduced due to characteristics of the module Maximum opera...

Страница 11: ...frame hole passed a mechanical load test item in accordance with the IEC 61215 and UL 1703 standard and S Energy Co Ltd recommends the following method of installing a frame hole As described in fig...

Страница 12: ...iron glass and the ARC glass to minimize with light reflection Cleaning time is taking into account the thermal shock and power generation please proceed early in the morning and cloudy weather Clean...

Страница 13: ...97 V 18 96 325 W 33 60 V 9 68 A 325 W 10 11 A 41 11 V 19 26 40 to 85 1 000V A 20 0 3 Rated Power Pmax Voltage at Pmax Vmp Current at Pmax Imp Warranted Minimum Pmax Short Circuit Current Isc Open Cir...

Страница 14: ...S Energy PV Module Installation Manual 1 Hole installation method Installation Instructions 12 11 2 Location and method of clamp installation...

Страница 15: ...the frame Be sure to avoid shadowing effects from the module clamps When choosing this type of clamp mounting method use at least four clamps on each module two clamps should be attached on each long...

Страница 16: ...ergy com en H E A D O F F I C E C O N T A C T Fl3 MiraeAsset Tower 20 Pangyoyeok ro 241 beon gil Bundang gu Seongnam Gyeonggi do 13494 Republic of KOREA Tel 82 70 4339 7100 Fax 82 70 4339 7199 E mail...

Отзывы: