5

SPECIFIC SAFETY RULES FOR GENERATOR

SPECIFICATIONS

PREPARING THE GENERATOR FOR USE

DESCRIPTION

1. Exhaust fumes are poisonous. 

Never operate engine

    indoors. 

2. Fuel is highly flammable. 

Stop engine when Refuling  

    and never near naked flames . 

3. No smoking when refueling. 
4. Take care not to spill fuel when refueling. 
5. Never operate in rain, snow or any wet weather. 
6. Avoid placing flammables in the vicinity of the 

    engine. 

Keep more than 1 meter away. 

7. After starting the generator, some parts of engines 

    and exhaust (such as muffler, pipe, cylinder head and  

    etc) will be very hot, do pay attention to the warnings 

    on the generator, don’t touch them when generator

    being operated or 10 minutes after the closed.

Engine type ...................................... 

Rated power ......................................................... 

Max. output ........................................................... 

Voltage ...................................................................

Frequency ............................................................... 

Displacement ........................................................

Fuel tank capacity  ...................................................

Run time per tank ...................................................

Net weight .............................................................

4-stroke, air cooled

2.5kW

3.0kW

230V

50Hz

212cc

15L

7Hrs

44kgs

  1. Fuel tank cap

  2. Engine key switch

  3. “AC” Switch

  4. Voltage meter

  5. Ground terminal

  6. AC receptacle

  7. Oil filler/ dip stick

8. Never touch the generator with wet hands.
9. Do not cover the generator with a cloth. 

The machine 

    needs a free flow of air to operate.

10. Always ground (earth) the generator.
11. Do not connect the generator to commercial power

      outlet.
12. Do not connect the gnerator with another generator.
13. Do not fill above fuel filter top.
14. Fuel is easily evaporated. After refuel please screw 

      the tank cover tightly, please use unleaded petrol 

      #93 or more.

Place generator on level ground, keep balance.

NOTE:

The generator requires engine oil to operate properly. When 

the generator new from the package, contains no oil in the 

crankcase. You must add the proper amount of oil before

operating the generator for the first time. This amount, which 

is equal to the oil capacity (0.6L) of the engine crankcase.

If you are using the generator for the FIRST TIME, there 

are a few steps you must take to prepare it for operation.

ADD OIL

USING THE GENERATOR FOR THE FIRST TIME

SUBSEQUENT USE OF THE GENERATOR

CAUTION!

Do not apply engine oil with additives or 2-stroke petrol 

engine oil, as they haven’t enough lubrication, which may 

shorten the engine’s service life.

Please use 4-stroke petrol engine oil.

To add oil, follow these steps:
1. Make sure the generator is on a level surface.

2. Unscrew the oil filler/dipstick cap from the engine (Fig. 1).

3. Using a funnel, add the appropriate amount of oil into the 

    crankcase. You will know the crankcase is full when the oil 

    level has reached the lower lip of the opening you have 

    just poured the oil into (Fig. 2).

4. Replace oil filler cap.

Petrol and fuel fumes are highly flammable.

• Do not fill tank near an open flame.

• Do not overfill. Always check for fuel spills.

To ensure that the generator runs smoothly use only FRESH, 

UNLEADED FUEL WITH AN OCTANE RATING OF 93 OR 

HIGHER. 
To add petrol:
1. Make sure the generator is on a level surface.

2. Unscrew fuel cap and set aside. 

    

NOTE:

 the fuel cap may be tight and hard to unscrew.

3. Slowly add unleaded petrol to the fuel tank. The fuel 

    tank capacity is 15L (4.0 gallons), be careful not to overfill. 

    The fuel gauge on the top of the generator indicates how 

    much petrol is in the generator fuel tank.

    

NOTE: 

fuel can expand. Do not fill the fuel tank to the 

                very top.

4. Replace fuel cap and wipe up any spilled petrol with a 

    dry clothe.

• Never use an oil/petrol mixture.

• Never use old fuel.

• Avoid getting dirt or water in the fuel tank.

• fuel can age in the tank and make it hard to start up the 

  generator in the future. Never store generator for extended 

  periods of time with fuel in the tank.

IMPORTANT!

IMPORTANT!

WARNING!

If this is NOT YOUR FIRST TIME using the generator 

there are still steps you should take to prepare it for 

operation.

At this point you should be familiar with the procedures 

described in the first portion of this section entitled "USING 

THE GENERATOR FOR THE FIRST TIME." If you have not 

yet read this section, go back and read it now.

ADD PETROL

DC cable, Spark plug wrench 

ACCESSORIES:

Содержание RG-3500

Страница 1: ...ons there will be CO so never use in an enclosed room without good ventiation When the oil level is too low the engine oil warning system will be automatic to stop running trom damaging the engine YEA...

Страница 2: ...ill be CO so never use in an enclosed room without good ventiation When the oil level is too low the engine oil warning system will be automa tic to stop running trom damagi ng the engine YEAR201 5 Ra...

Страница 3: ...2 5 6 7 8 9 10 3 4 ON CLOSE OPEN OFF ON START ENG SW OFF ON START ENG SW...

Страница 4: ...3 11 12 13 14 15 16 OFF Fuel filter cup Fuel valve OFF ON START ENG SW Drain plug Element 17 18 0 7 0 8mm Plug wrench Plug cap Filler cap Air cleaner cover Cover spring Cover spring...

Страница 5: ...protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avoid accidental starting Ensure the...

Страница 6: ...to prepare it for operation ADD OIL USING THE GENERATOR FOR THE FIRST TIME SUBSEQUENT USE OF THE GENERATOR CAUTION Do not apply engine oil with additives or 2 stroke petrol engine oil as they haven t...

Страница 7: ...output ability of the generator covers this extra power requirement The total running wattage requirement of the electrical devices connected to the generator should not exceed the Rated power of the...

Страница 8: ...ance please take off the key and spark plug cap CLEANING THE GENERATOR Always try to use your generator in a cool dry place However in the event your generator becomes dirty you may clean the exterior...

Страница 9: ...ed or chipped discard and replace with a new spark plug 4 Measure the plug gap with a gauge Fig 18 The gap should be 0 7 0 8mm 0 028 0 031 in 5 If you are re using the spark plug use a wire brush to c...

Страница 10: ...level surface to prevent low oil shutdown from triggering Engine will not start Circuit breaker is off Set the circuit breaker to the on position Bad connecting wires cables If you are using an exten...

Страница 11: ...10 NOTE...

Страница 12: ......

Отзывы: