background image

SYMBOLS

16

Safety Alert Symbol

Indicates danger, warning or caution. It means attention!!! 
Your safety is involved.

Read Your Operator's
Manual

Your manual contains special messages to bring attention
to potential safety concerns as well as operating and 
servicing information. Please read all the information 
carefully to ensure satisfaction and safe use.

Wear Hearing Protection

Hearing protection must be worn when operating this 
equipment.

Air and condensation water can burst from the 
compressor when the drain plug is removed.

Risk of Bursting

Risk of Electric Shock

Hazardous Voltage. Disconnect from power source before
servicing. Do not use in damp conditions.

Hot Surface

To reduce the risk of injury or damage, avoid contact with
any hot surface.

Enclosure Alert

Do not operate the portable compressor with the doors 
or enclosure open.

Unexpected Starting

The compressor may start without warning.

Recycle Symbol

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. 
Check with your Local Authority or retailer for recycling 
advice.

CE Marking

Conforms to relevant safety standards.  

Oil

Use SAE-30 non-detergent (API CG/CD Heavy Duty) oil.

To stop the compressor, use the switch located on the
pressure switch body. Never use the main switch or
unplug the compressor.

Do Not Pull Out The
Plug.

Содержание RC-3150B

Страница 1: ...njoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz Rated power 2 2kW 3 0HP Receiver capacity 150l Type Oil lubricated Free air delivery FAD 365l min Oil type SAE 30 Oil capacity 500m...

Страница 2: ...s and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lub...

Страница 3: ...e Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 10 bar or more should be used Never attempt to re pair faulty...

Страница 4: ...with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer an...

Страница 5: ...t is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substa...

Страница 6: ...Castor wheel 7 Wheel x 2 8 Drain valve 9 Air receiver tank 10 Oil drain plug 11 Dipstick 12 Air filter 13 Air outlet pressure regulator 14 Air outlet quick release connector regulated 15 Air outlet p...

Страница 7: ...NTS Belt driven compressor Wheels x 2 Wheel fixings bolt nut x 2 Castor wheel Rubber foot and rubber foot fixing nut Dipstick Operator s Manual WARNING If any parts are damaged or missing do not opera...

Страница 8: ...ase all tank air pressure before removing the dipstick Be sure the air vent in dipstick Fig 3 is free from debris If air vent is blocked pressure can build in crankcase causing damage to the compresso...

Страница 9: ...used play an important role in the operation of this product Wiring intended for lights cannot properly carry an air compressor motor and wire that is heavy enough for a short distance may be insuffic...

Страница 10: ...on pressed in Fig 6 Check that the air outlet pressure regulator is closed Fig 7 Check that the drain valve is closed Fig 8 Connect the compressor to a suitable 16A mains supply Switch on the compress...

Страница 11: ...t the same time observing the air outlet pressure gauge until the pressure gauge reads the minimum pressure for the accessory Fine adjustments to the air pressure can be made until the accessory is wo...

Страница 12: ...ndensation Carefully undo the drain valve nut anti clockwise until you hear a hissing noise this is the reservoir depressurising Fig 15 When the gauge indicates zero and the hissing has stopped tighte...

Страница 13: ...move the securing bolt and pull the filter from the compressor Fig 16 Unclip the front and rear of the filter and pull out the filter element Fig 17 Clean the filter using a soft brush If necessary th...

Страница 14: ...it is advisable to give the compressor a thorough clean This should include the removal of all fitted accessories Do not use any solvents as these can damage plastic parts Only use a clean cloth dampe...

Страница 15: ...hten if necessary Switch off and wait approx 5 minutes Press the reset button and switch on again Contact your nearest service agent Return the machine to your nearest service agent Open drain valve t...

Страница 16: ...dous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Enclosure Alert Do not op...

Страница 17: ...17 NOTES...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ......

Отзывы: