background image

13

SYMBOLS

Safety Alert Symbol

Indicates danger, warning or caution. It means attention!!! 
Your safety is involved.

Read Your Operator's
Manual

Your manual contains special messages to bring attention
to potential safety concerns as well as operating and 
servicing information. Please read all the information 
carefully to ensure satisfaction and safe use.

Wear Eye and Hearing
Protection

Eye and hearing protection must be worn when operating 
this equipment.

Risk of Electric Shock

Hazardous Voltage. Disconnect from power source before
servicing. Do not use in damp conditions.

Hot Surface

To reduce the risk of injury or damage, avoid contact with
any hot surface.

Unexpected Starting

The compressor may start without warning.

Recycle Symbol

Waste electrical products should not be disposed of with 
household waste. Please recycle where facilities exist. 
Check with your Local Authority or retailer for recycling 
advice.

CE Marking

Conforms to relevant safety standards.  

Air and condensation water can burst from the 
compressor when the drain plug is removed.

Risk of Bursting

Enclosure Alert

Do not operate the portable compressor with the doors 
or enclosure open.

Содержание RC-2050NV

Страница 1: ... is intended you will enjoy years of safe reliable service SPECIFICATIONS Voltage 230V 50Hz R Intermittent duty S3 25 ated power 1 5kW 2 0HP Receiver capacity 50l Type Oil free Free air delivery FAD 222l min CFM 7 8 Working pressure 10bar 145psi No load speed 3400min 1 Sound pressure level LpA75 5dB A k 3dB A Sound power level LWA 95 5 dB A k 3dB A Net weight 22 2kg THANK YOU FOR BUYING A RYOBI OI...

Страница 2: ... The warnings and safety instructions must be followed to ensure reasonable safety and efficiency in using this product NOTE The operator is responsible for following the warnings and safety instructions in this manual and on the product Ensure that this compressor is disconnected from the mains supply when not in use and the air receiver fully discharged before servicing lubricating or making adj...

Страница 3: ...afe Never weld or drill holes in the air tanks Only use recommended parts To avoid the risk of bursting only hoses with a rated pressure of 8 bar or more should be used Never attempt to repair faulty hoses Avoid kinking or trapping the air hose Always replace faulty hoses never attempt a repair if a leak is detected Make sure the hose is free of obstructions or snags Entangled or snarled hoses can...

Страница 4: ... with ANSI Z87 1 c Additional safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When requ...

Страница 5: ...ompressor ELECTRICAL ELECTRICAL CONNECTION This product is powered by a precision built electric motor It should be connected to a power supply that is 230 V AC only normal household current 50 Hz Do not operate this product on direct current DC A substantial voltage drop will cause a loss of power and the motor will overheat If the product does not operate when plugged into an outlet double check...

Страница 6: ...le 2 On Off switch 3 Wheels 4 Condensation drain tap 5 Rubber foot 6 Air receiver tank 7 Shroud 8 Air outlet pressure gauge 9 Air outlet quick release connector regulated 10 Pressure regulator DESCRIPTION 1 2 3 7 6 8 4 5 9 10 ...

Страница 7: ...Rubber foot Rubber foot fixings bolt washer nut x 2 Operator s Manual WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury WARNING Do not connect to power supply until assembly is complete Failure to comply could result in accidental starting and possible seriou...

Страница 8: ...R COMPRESSOR Before moving the compressor switch off and disconnect it from the mains power supply Always use the handle Do not lift by or put strain on air taps valves or hoses Take care when moving the compressor to avoid damaging the valves or fittings The compressor is heavy take care when lifting and moving this compressor to avoid personal injury Get assistance if necessary This is an oil le...

Страница 9: ... zero 0 psi Connect a hose to the compressor using the hose to compressor quick release connector Fig 3 Make sure to push the air fitting fully into the coupler until the sleeve springs forward to lock in place To disconnect an air hose or an air tool Confirm that the outlet pressure is at zero 0 psi When disconnecting a hose from the quick release connector always firmly hold the fitting end of t...

Страница 10: ...ltage is 230V The ON OFF switch is in the OFF non depressed position The pressure regulator should be set at its lowest setting i e turned fully anticlockwise If the machine has not been used for 24 hours or so open the drain valve tap to drain any condensate which may have accumulated When clear close the valve Important If the receiver is under pressure keep your hands well away from the air bei...

Страница 11: ...any maintenance always disconnect the compressor from the mains supply drain the air receiver and if necessary allow the machine to cool down before starting work GENERAL MAINTENANCE The compressor must be drained completely by opening the drain tap Drain the air receiver tank after approx 2 hours of use WARNING If the water that condenses is not drained it may corrode the receiver reducing its ca...

Страница 12: ...ucts in the conveyor Ventilate the work area Activate the on off switch Ventilate the work area Wait a few minutes The compressor will restart independently Remove any power cable extensions Remove the plug and contact the Service Centre SERVICE Now that you have purchased your tool should a need ever exist of repair or service simply contact your nearest Ryobi Authorised Service Centre or other q...

Страница 13: ... Hazardous Voltage Disconnect from power source before servicing Do not use in damp conditions Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Unexpected Starting The compressor may start without warning Recycle Symbol Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority ...

Страница 14: ...NOTES 14 ...

Страница 15: ...15 NOTES ...

Страница 16: ......

Отзывы: