TROUBLESHOOTING
12
PROBLEM
POSSIBLE CAUSE
REMEDY
Reduction of performance.
Frequent start-up.
Low pressure values.
The compressor stops and
restarts automatically after
a few minutes.
After a few attempts to
restart, the compressor
stops.
The compressor does not
stop and the safety valve
is tripped.
Excessive performance request,
check for any leaks from the
couplings and/or pipes. Intake
filter may be clogged.
Tripping of the thermal cutout due
to overheating of the motor.
Tripping of the thermal cutout due
to overheating of the motor
(removal of the plug with the
compressor running, low power
voltage).
Irregular functioning of the
compressor or breakage of the
pressure switch.
Replace the seals of the fitting, clean
or replace the filter.
Clean the air ducts in the conveyor.
Ventilate the work area.
Activate the on/off switch. Ventilate the
work area. Wait a few minutes. The
compressor will restart independently.
Remove any power cable extensions.
Remove the plug and contact the
Service Centre.
SERVICE
Now that you have purchased your tool, should a need ever exist of repair or service, simply contact your
nearest Ryobi Authorised Service Centre or other qualified service organistion. Be sure to provide all
pertinent facts when you call or visit.
SYMBOLS
SYMBOL
SIGNAL
MEANING
DANGER:
Indicates an imminently hazardous situation, which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may result
in minor or moderate injury.
CAUTION
(Without Safety Alert Symbol) Indicates a situation that may result in
property damage.