14
OPERATiON
QUiCk SHUTOff SWiTCH
See Figure 15.
Depress the quick shutoff switch at any time to stop the
inflator.
DiGiTAL GAUGE
See Figures 15.
NOTE:
Digital gauge displays pressure of high
pressure hose only. Preset features apply to high pressure
applications only.
The digital gauge on the inflator is multifunctional. It serves
as a pressure gauge, monitors the amount of pressure being
applied to the item being inflated, and can change air pres-
sure measurement units from PSI to BAR to KG/CM
.
To turn the digital gauge
ON
, press the
ON/RESET
button
or depress the switch trigger.
NOTE:
Make sure digital gauge is set at 0 before use. If gauge
reads “Err” or needs resetting, press and hold
ON/RESET
button for 4-7 seconds.
NOTE:
The digital gauge will automatically shut off when not
in use for and a half minutes or more.
To use the pressure gauge feature:
Turn digital gauge on by pressing
ON/RESET
button or
depressing and releasing switch trigger.
Place air chuck over valve stem and lock in place. Readout
will appear on gauge.
NOTE:
The pressure readout on the gauge while inflating
is a measurement of the fluctuating pressure between the
item and the high pressure hose. To get an accurate read-
ing, stop inflating and follow above instructions for reading
the air pressure.
To switch from PSi, kG/CM
2
, and BAR:
With gauge
ON
, press and hold down
ON/RESET
button
for a
t least 7 seconds.
The current measuring unit will flash. Press the
ON/RESET
button again to select the desired measur-
ing unit.
The setting takes effect after the display stops flashing.
(4-7 seconds)
NOTE:
After preset pressure has been set, pressure setting
stays in the gauge memory for 10 seconds. To recall the
previous pressure setting for up to 10 seconds after infla-
tion, press the (
+
) or (
-
) button.
To reset preset pressure, press and hold the
ON/RESET
button.
iNfLATiNG MANUALLY fOR HiGH AND LOW
PRESSURE APPLiCATiONS
Connect either high
or low pressure hose to item to be
inflated.
Depress and hold switch trigger until desired pressure is
reached.
Release the switch trigger.
PRESSURE
GAUGE
(+)
BUTTON
(-)
BUTTON
ON/RESET
BUTTON
Fig. 15
AIR PRESSURE
QUICK
SHUTOFF
SWITCH
iNfLATiNG USiNG THE PRESET PRESSURES
fEATURE WiTH AUTOMATiC SHUTOff
NOTE:
Digital gauge displays pressure of high pressure
hose only.
With gauge
ON
, press and hold down (
+
) or (
-
) buttons
to select desired shutoff pressure.
NOTE:
Numbers will flash while setting pressure. Holding
buttons down will make the pressure number increase/
decrease faster.
Depress switch trigger.
Push the lock-on button forward.
Release the switch trigger and the inflator will continue
running.
NOTE:
For preset pressures of 39 PSI, .68 BAR, or .74
KG/CM
or less, the unit will automatically stop just short
of the preset pressure. Manually depress the switch trigger
again to release the lock-on button and provide an additional
short “burst” of air to achieve preset pressure.
For preset pressures of 40 PSI, .75 BAR, or .74 KG/
CM, or greater, the unit will automatically stop at 40 PSI,
.75 BAR, or .74 KG/CM regardless of preset pressure
setting. This feature helps guard against over inflation and
possible bursting. Manually depress the switch trigger again to
release the lock-on button and continue inflating by hold-
ing the trigger in the
ON
position to achieve desired pres-
sure. Shutoff will occur again just before target pressure is
reached.
NOTE:
Read actual pressure only when unit is not
operating.