Rycom STX10 Скачать руководство пользователя страница 7

INITIAL SET-UP INSTRUCTIONS

INSTRUCTIONS

1. Remove the Charging Cradle, USB Power Cord and AC Adaptor from packaging.
2. Plug the USB Power Cord into Charging Cradle and into the AC Adaptor. Plug the AC 
    Adaptor into a power outlet. The unit is designed for 110-volt power ONLY. 
3. Remove Non-Contact Professional Thermometer from packaging and place in the 
   Charging Cradle. Allow unit to charge for a minimum of 4 hours before first usage. 
   A full charge will last for approximately 1,000 temperature readings. 
4. The calibration of Sanomedics Non-Contact Professional Thermometer is factory-set, 
   however for the most accurate results the device’s calibration should be checked in the 
   medical setting in which it will be used. Please note, depending on various skin types and 
   thickness, there may be temperature differences. 

The F4 function menu will allow unit calibration. To calibrate, measure an individual’s 
temperature using a conventional thermometer and measure it concurrently using the 
Non-Contact Professional Thermometer. If there is a difference between the two readings, 
recalibrate the Non-Contact Professional Thermometer. 

Instructions for recalibration:

Press the “MODE” and “°C/°F” buttons at the same time for 3 seconds. The screen will 
then display: ”F4”
Press “Mode” to increase 0.1°F, press “ °C/°F ” to reduce 0.1°F.
Press “MEM” button to save the setting.

In the cases of seasonal or environmental changes a verification and adjustment should 
be carried out.

5. If a dramatic change in ambient room temperature occurs wait 10-15 minutes so the 
   unit can become acclimated to the new room temperature.

1. For optimal results, allow the unit to acclimate to the ambient room temperature for 
   10-15 minutes before the first usage of the day.
2. Before taking an individual’s temperature, make sure to remove hair and wipe 
   perspiration from the forehead.
3. Avoid any drafts from nasal specs, air conditioning etc…
4. Aim at the FOREHEAD, above the right eye, holding the unit approximately 1-2 inches 
   (5 cm) from the body. Activate the thermometer’s target finding feature by depressing 
   the SCAN button, two red dots will appear on the subject’s forehead. Move the thermo-
   meter gradually towards, or away from, the patient until only one red dot is visible – this 
   is the optimal range for temperature measurement. Press the Scan button a second time 
   to measure temperature. Results will be displayed in less than one second.
5. Each time there is a significant change in the ambient temperature due to a change in 
   environment, allow the Non-Contact Professional Thermometer to acclimate to the new 
   ambient temperature for at least 15 minutes before using.

7

Содержание STX10

Страница 1: ...Non Contact Thermometer Professional...

Страница 2: ...ometer can also be used to measure the temperature of a baby bottle bath or room using the surface temperature function SAFETY PRECAUTIONS s OLLOW THE MAINTENANCE ADVICE STIPULATED IN INSTRUCTIONS s O...

Страница 3: ...FFESIONAL THERMOMETER WORKS All objects solid liquid or gas emit energy by radiation The intensity of this energy depends on the temperature of the object The Non Contact Professional Thermometer is a...

Страница 4: ...wered for three to four minutes which is a difficult task for young children to accomplish Axillary armpit temperature Although it may be easy to measure axillary temperature it has been proven that i...

Страница 5: ...s 96 6 99 7 35 9 37 6 65 years 96 4 99 5 35 8 37 5 Practical considerations when taking a temperature s N ORDER TO ENSURE THAT PRECISE AND ACCURATE TEMPERATURE MEASUREMENTS ARE OBTAINED IT IS essentia...

Страница 6: ...ehind the ear lobe although the primary and most optimal area is the above the right eye 6 Basic Instrument Layout Infrared Lens LCD Display Mode Scan Button Charging Dock Celsius and Fahrenheit Memor...

Страница 7: ...seconds The screen will then display F4 Press Mode to increase 0 1 F press C F to reduce 0 1 F Press MEM button to save the setting In the cases of seasonal or environmental changes a verification an...

Страница 8: ...gs recalibrate the Non Contact Professional Thermometer Instructions for recalibration Press the MODE and C F buttons at the same time for 3 seconds The screen will then display F4 Press Mode to incre...

Страница 9: ...e in the upper right portion of the display window The red LED light will remain illuminated until the device is fully charged While charging and in the Charging Cradle the device will display the amb...

Страница 10: ...rofessional use Its longevity is designed for 40 000 readings Accessories User manual in English Charging Cradle USB Power Cord AC Adapter Breakaway Safety Lanyard Maintenance of the Product The prote...

Страница 11: ...her above 109 F 42 9 C in Body mode or above 244 4 F 118 C in Surface Temp mode THE SCREEN DISPLAYS THE MESSAGE LO When using the Non Contact Professional Thermometer the message LO can show on the sc...