8. Connect the power supply wires (red and black wires on rear of water heater) to the appropriate nominal 12V DC power
source connection.
NOTE
: The red wire is positive (+) and the black wire is negative (-).
9. Connect the wall controller wires (2 blue wires on the appliance).
NOTE
: Polarity does not matter, the wires can be connected to either blue wires.
10. Connect the HOT and COLD water lines to the appropriate connections on the back of the appliance using ½” NPT
connections.
DO NOT
overtighten.
11. Apply adequate amounts of water sealing material (ex. butyl tape 1 inch wide, not included) around the entire backside of
the front flange and any holes.
DO NOT
use adhesive sealing material (ex. silicone) for the watertight seal.
12. Slide appliance through the cutout fully until the front flange is contacting the RV sidewall.
13. Secure the flange to the sidewall using fasteners, preferably stainless steel or corrosion resistant.