System Settings with DHCP-Server
The TCR IP 4 allows the switch-
ing of electrical devices via the
TCP/IP-network. The device is lo-
cated in a housing for mounting
on a DIN-rail.
The TCR IP 4 can be switched
from all computers of the same
network with their web browser
by IP-address 192.168.0.3.
A local operation is possible with
the built-in or external connected
push-buttons. The actual switch-
ing state of an output is indicated
by a LED located at the push-
button for switching.
The TCR IP 4 has an integrated
time switching function. For each
switching output, up to 5 switch-
ing on or switching off times can
be selected. With a web browser
it is possible to display the actual
temperature at connected tem-
perature sensor as well as the
settings of the network character-
istics and the time switch.
The TCR IP 4 can also be oper-
ated from the Internet if there is a
fixed IP-address or a DNS-server
for the translation of the dynamic
IP in a host name provided. The
TCR IP 4 can also be operated
from a mobile phone, if this sup-
ports JavaScript.
3
System Settings without DHCP-Server
1 Connect the TCR IP 4 with a
patch cord (separately avail-
able) to the local network.
2 Connect the temperature
sensor (optional) at the screw
terminals.
3 Connect the TCR IP 4 to the
230-V-power supply.
4 After entering the address
http://192.168.0.3 or
http://TCRIP4 (factory set-
tings), the TCR IP 4 can be
reached with a browser.
5 Choose the button ”network
configuration” in the main
menu (figure 2, 1).
6 For calling the TCR IP 4 di-
rectly, choose an individual
”network name”.
7 Modify the IP-address of the
TCR IP 4 to particular needs.
8 With ”send” the configuration
will be saved.
Figure 2
1 Connect the TCR IP 4 with a
patch cord (separately avail-
able) to the local network.
2 Connect the temperature
sensor (optional) at the screw
terminals.
3 Connect the TCR IP 4 to the
230-V-power supply.
4 After entering the address
http://192.168.0.3 or
http://TCRIP4 (factory set-
tings), the TCR IP 4 can be
reached with a browser.
5 Choose the button ”network
configuration” in the main
menu (figure 2, 1).
6 In order to call up the TCR IP
4 directly, choose under ”net-
work name” an individual
name.
7 Now activate the DHCP-
server (figure 2, 2).
8 The TCR IP 4 will be as-
signed a free IP-address.
Settings
3
1
2
Warning:
Work on the
230-V-supply may only be
carried out by authorized
electricians!
Danger for life!
Disconnect the main volt-
age before installation.
In order to fulfill the general
safety regulations for telecommu-
nications systems and to avoid
disturbances, the DIN VDE 0100
part 520, respectively, the prEN
50174-2, section 5.4 and 5.5
must be taken into account:
A physical separation or suitable
partition wall must be provided
(clearance or shielding).
Pay attention to the shock-proof
protection of the heavy-current
The shock-proof protection must
also be guaranteed, when you
have removed the common cov-
ering (this is not always given for
old installations).
Take care that the minimum dis-
tance of 10 mm between data-/
telecommunication cables and
heavy-current cables are strictly
observed during the erection of
combined plants.
Working in existing data networks
requires – if necessary – the as-
sent of the respective person in
charge of network and data as
well as a preceding data security.
Please also observe the permit-
ted operating temperature, do
not place the Patch panel directly
beside devices with high heat
evolution (e.g. dimmer).
Installation
General