background image

TCR IP 4

Operating Instructions

Содержание TCR IP 4

Страница 1: ...TCR IP 4 Operating Instructions ...

Страница 2: ...ing Function 5 Switching of the TCR IP 4 via the internet 6 Switching of the TCR IP 4 with your mobile phone 6 Troubleshooting 6 Technical Data 7 Manufacturer s Warranty 7 Service 7 Manufacturer s Declaration 7 Disposal 7 Scope of delivery Accessories optional Temperature sensor 700 802 201 push button for manual switching LED activity to 230 V power supply network connection screw terminals for t...

Страница 3: ...needs 8 With send the configuration will be saved Figure 2 1 Connect the TCR IP 4 with a patch cord separately avail able to the local network 2 Connect the temperature sensor optional at the screw terminals 3 Connect the TCR IP 4 to the 230 V power supply 4 After entering the address http 192 168 0 3 or http TCRIP4 factory set tings the TCR IP 4 can be reached with a browser 5 Choose the button n...

Страница 4: ...ts which are found in the menu bar With send the configuration will be saved 1 Settings The factory settings of the deli very state can be replaced with individual settings In order to reload the factory settings sepe rate the TCR IP 4 from the 230 V power supply Press both push buttons of the device and switch on the device with pressed buttons After about 3 seconds the LED starts blinking to ind...

Страница 5: ...the switching output 1 of the TCR IP 4 and will be switched on Monday to Friday at half past 5 30 am in the morning no 1 and switched off at 5 00 pm no 2 It is even possi ble to select one time switching on a certain date At switching output 2 is the light ing of the staircase of the com pany connected The lighting of the courtyard is connected to the switching ou put 3 The user is also able to sw...

Страница 6: ...o the valid IP address during the actual session Following steps are necessary A DNS server provider for the translation of the dynamic IP in to a host name i e free of charge provider DynDNS www dyndns com Optionally additional software to ensure that after an inter ruption of a session the trans lation will be done again This software is also free of charge and also available at the provi der i ...

Страница 7: ...r send it with the receipt an a short description of the mal function to the following address Rutenbeck Service Center Gewerbegebiet Im Meilesfeld 5 99819 Marksuhl Germany Phone 49 36925 90091 Fax 49 36925 90092 We guarantee the perfect func tion of the TCR IP 4 for 2 years after date of purchase receipt assuming that it was profession ally installed and operated We Wilhelm Rutenbeck GmbH Co KG d...

Страница 8: ... Wilhelm Rutenbeck 2010 20201201 Status 11 04 Subjected to technical changes Niederworth 1 10 58579 Schalksmühle Germany Phone 49 2355 82 0 Fax 49 2355 82 105 www rutenbeck de mail rutenbeck de ...

Отзывы: