INSTALLATION OVERVIEW

Ventilation Requirements

Important:

 The MCA-88 should be situated so that its location or position 

does not interfere with its proper ventilation. Do not block vents above or to 

the sides of the unit, as it requires ventilation for proper operation. Do not 

expose to excessive dust, and do not allow dust to build up on the unit and 

block vent holes. Do not place the MCA-88 above or below a heat-generating 

component such as an audio amplifier. 

Be sure to leave at least 2 inches of space to the sides of the unit with open air 

flow above. A single-space rack mount vent or about 1.75 inches must be kept 

clear above and below the unit.

Installation

The MCA-88 controller can be rack mounted or placed on a shelf in an 

equipment rack. The controller occupies two rack spaces with the feet 

removed. 

The controller can be installed in an equipment rack using the included  

rack-mount ears and hardware to attach the ears to the controller chassis. 

Up to six controllers can be connected for up to 48 zones on the system. 

Electrical Power

The MCA-88 operates at 100-120VAC ~60 Hz or 220-240VAC ~50 Hz. Voltage 

is selected by the voltage switch on the rear panel and incorporates the 

appropriate detachable power cord. It is recommended that the MCA-88 and 

the source equipment be plugged into a dedicated 20-amp circuit. A power 

line conditioner can reduce interference problems caused by noise found in 

some electrical systems. 

The power switch for the unit is on the front panel. 

Important Considerations

•  Disconnect the power cord before making any connections to the 

controller.

•  Verify that all connections and polarity are correct.
•  Keep all power cords away from all signal cables to prevent humming from 

induced noise.

•  Choose reliable signal cables and patch cords.
•  Label all wires with the room location at both ends of the wire.
•  Avoid running speaker wires or signal cables close to house electrical 

wiring for any distance. If you have to run them parallel, make sure to space 

the wires at least two feet from the AC line. If you need to cross an AC line it 

should be at a 90° angle.

•  For multiple controllers, the controller ID must be set with the rotary switch 

on the rear panel. Each controller must be set to a unique number before 

powering connected controllers.

Important: 

Basic Source and Zone name configuration can be done 

with Web-SCS on a smartphone, tablet, or laptop. More detailed system 

configuration, such as IR programming, can be completed with the free SCS-C5 

software available at  www.russound.com.

Do not connect the controller’s main power feed until all other 

connections have been made and verified. Live connection or 

removal of the keypad wiring or other wiring when the system 

is powered can result in erratic operation or system damage.  

Double-check terminations during each phase of the installation 

to prevent accidental damage. Incorrect wiring is the number one 

cause for non-warranty product damage.

Содержание MCA-88

Страница 1: ...MCA 88 8 Source 8 Zone Controller Amplifier Installation Manual...

Страница 2: ...is required for obtaining the most recent firmware Note If an internet connection will not be available at the place of installation the installation location please download the latest firmware from...

Страница 3: ...ypad Connections 10 Speaker Connections 11 Source Connections 12 Bluetooth and Digital Inputs 13 Ethernet Connection and Factory Reset 13 Multiple Controller Installation 14 Zone Amplification 15 Page...

Страница 4: ...g metadata song artist and other information for display on the keypads Audio paging with a 12VDC trigger input Party mode Do Not Disturb and source zone linking options SCS C5 CONFIGURATION SOFTWARE...

Страница 5: ...d to the All ON command Page Participation defines whether a zone will respond to a page event Page Volume sets the volume of a page event in each zone Power Management of Sources enabled disabled per...

Страница 6: ...CONTROLLER FRONT PANEL Removable Cover to access IR window IR Programming IR Receiver Window Zone LED Indicators visible behind cover Power Button Red LED indicates Power On Front Panel Front Panel wi...

Страница 7: ...sensing stereo line level inputs and loop outputs IR Outputs Up to 6 routed IR outputs shared for 1 7 and 2 8 1 common IR output Keypad Ports RJ 45 Connections for zone keypads Home Theater 12VDC Tri...

Страница 8: ...itioner can reduce interference problems caused by noise found in some electrical systems The power switch for the unit is on the front panel Important Considerations Disconnect the power cord before...

Страница 9: ...ize a UL CSA approved electrical box at the keypad double gang at least 32 cu in and controller locations Using connector specific wall plates at the controller location will better organize all of th...

Страница 10: ...ct from the keypad port to a RJ 45 wall plate optional Using the same T568A RJ 45 wiring configuration use CAT 5e cable from the wall plate to the keypad Maximum CAT 5e cable length is 250 feet betwee...

Страница 11: ...at a time starting with Zone 1 taking care to keep zone and speaker wire identities straight Strip 1 to 2 inches 2 5 to 5 cm off the end of each speaker cable jacket Then strip 1 4 inch 0 7 cm of ins...

Страница 12: ...Link ports on the controller to either of the two RNET Link ports of the RNET enabled source RNET ports are parallel bidirectional connections meaning that the ports are identical and either one can...

Страница 13: ...able as either analog or digital inputs The Web SCS or SCS C5 software enables you to designate whether to use the analog connection or the digital connection for each source Source 5 has three connec...

Страница 14: ...he BTC 1X Bluetooth on Source 1 connect the Source 1 OUT on Controller 1 to the Source 1 IN on Controller 2 Continue the audio loop to other controllers if necessary Note Only a single BTC 1X may be c...

Страница 15: ...D250LS is perfect for such applications Common 12VDC Trigger Output The Com 12VDC 100mA Out can be used to trigger additional amplification when needed This output supplies 12VDC 100mA when any one zo...

Страница 16: ...then only seven other source inputs are available Page Trigger IN The page trigger input is used to trigger a page event Paging is configurable per zone using SCS C5 software A 12VDC trigger selects...

Страница 17: ...nd to the sources While all zones are still OFF and 12VDC is removed the system will wait 5 minutes and then activate the power management OFF command to the sources System On at least one zone is on...

Страница 18: ...mitter and attach the emitter over the source component s IR window When using the IR routed outputs in order to control this source component with IR the source must be selected at the keypad receivi...

Страница 19: ...nd the keypads are powered ON all thecorresponding zone LEDs on the face of the controller will be green Improper connection may cause one or more LEDs not to be lit Check all connections Cycle power...

Страница 20: ...r written permission Accidental damage and shipping damage are not considered defects nor is damage resulting from abuse or from servicing by an agency or person not specifically authorized in writing...

Страница 21: ...ing instructions or as marked on the appliance 12 Main Power Disconnect The power switch is a double pole switch When the switch is in the Off position the appliance is completely disconnected from th...

Страница 22: ...22 Russound MCA 88 Installation Manual...

Страница 23: ...23 Russound MCA 88 Installation Manual...

Страница 24: ...r respective owners Specifications are subject to change without notice Russound Inc 1 Forbes Road Newmarket NH 03857 tel 603 659 5170 fax 603 659 5388 email tech russound com www russound com 28 1391...

Отзывы: