Safety Instructions

Packaging material is dangerous to children. Never allow children to play 
with packaging material.

Risk of Death -

Always ensure adequate fresh air in the room if the 

appliance is being operated in extraction-air mode at the same time as 
room air-dependent heat-producing appliance(s) are being operated. 

Room air-dependent heat-producing appliances (e.g. gas, oil, wood or 
coal operated heaters, continuous flow heaters or water heaters) obtain 
combustion air from the room in which they are installed and discharge 
the exhaust gases into the open air through an exhaust gas system (e.g. a 
chimney).

In combination with an activated vapour extractor hood, room air is 
extracted from the kitchen and neighbouring rooms 

a partial vacuum is 

produced if not enough fresh air is supplied. Toxic gases from the 
chimney or the extraction shaft are sucked back into the living space.

Adequate incoming air must therefore always be ensured.

An incoming/exhaust air wall box alone will not ensure 
compliance with the limit.

Safe operation is possible only when the partial vacuum in the place 
where the heat producing appliance is installed does not exceed 4 Pa 
(0.04 mbar). This can be achieved when the air needed for combustion is 
able to enter through openings that cannot be sealed, for example in 
doors, windows, incoming/ exhaust air wall boxes or by other technical 
means.

In any case, consult your responsible Master Chimney Sweep. They will 
be able to assess the house's entire ventilation setup and will suggest the 
suitable ventilation measures to you. 

Содержание RHSCH601B

Страница 1: ...umber s RHSCH601SS M B M RHSCH901SS M B M Cooker Hood Instruction Manual IMPORTANT RETAIN FOR FUTURE REFERENCE For Customer Services Spare Parts please call 0345 208 8750 or visit us at mda russellhob...

Страница 2: ...ions 3 6 Product Overview 7 Positioning 8 Operating modes 9 Installation 10 12 Usage 13 Cleaning and Maintenance 14 20 Trouble shooting 21 Connection to the mains supply 22 Guarantee 23 Technical spec...

Страница 3: ...years old and are being supervised Keep children below the age of 8 years old at a safe distance from the appliance and power cable If the supply lead is damaged it must be replaced by a qualified pe...

Страница 4: ...extracted from the kitchen and neighbouring rooms a partial vacuum is produced if not enough fresh air is supplied Toxic gases from the chimney or the extraction shaft are sucked back into the living...

Страница 5: ...ket or something similar When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or...

Страница 6: ...am cleaners which can result in an electric shock Always switch on the appliance while cooking to avoid condensation Condensation can produce corrosion damage Always replace faulty bulbs to prevent th...

Страница 7: ...and fittings 7 x wall plugs 1 x hood fixing bracket 1 x flue fixing bracket 6 x small screws 2 of the 6 screws are spare screws 7 x large screws Unit Spare Parts If any of the above parts are missing...

Страница 8: ...nd gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed The exhaust air must not be conveyed into a functioning smoke or exhaust...

Страница 9: ...or exhaust gas flue obtain the consent of the heating engineer responsible If the extracted air is carried through the outer wall a telescopic wall box should be used Circulating air mode The air whic...

Страница 10: ...th of 50mm for the hood fixing bracket and press the wall plugs flush with the wall 5 Drill 2 x 10mm holes to a depth of 50mm for the flue fixing bracket and press the wall plugs flush with the wall a...

Страница 11: ...the hooks on the bracket are stepped and check that it is level with a spirit level 3 Remove the appliance from the hood fixing bracket and following installation remove the film completely 4 Attach...

Страница 12: ...both flue ducts 3 Place the hose on the duct outlet 4 Screw the upper flue duct to the sides of the flue fixing bracket using two small screws 5 Place the lower flue duct on the appliance and fix in...

Страница 13: ...trol panel The Fan Press the fan buttons to set the extraction rate fan speed that is required Press the fan off button to stop the fan The Lighting The lighting can be switched on and off independent...

Страница 14: ...rs or steam cleaners which can result in an electric shock Components inside the appliance may have sharp edges Wear protective gloves How to clean Observe the information in the table on the followin...

Страница 15: ...roduct with a soft cloth Painted surfaces Hot soapy water Clean using a damp dish cloth and dry with a soft cloth towel Do not use any stainless steel cleaners Aluminium and plastic Glass cleaner Clea...

Страница 16: ...and pull down the aluminium grease filter 2 Take the filter out of the holder 3 Clean the filter and allow to dry before replacing refer to cleaning instructions on the following page Installing 1 Ins...

Страница 17: ...ease filters 1 Remove the Aluminium filter s from the hood 2 You will now be able to access the motor carefully attached the carbon filters to both ends of the motor 3 Carbon filters should be replace...

Страница 18: ...eaned in the dishwasher or by hand Dishwasher 1 Do not clean heavily soiled metal mesh grease filters together with utensils 2 Place the aluminium grease filters loosely in the dishwasher 3 The filter...

Страница 19: ...off the circuit breaker in the fuse box Only use a light module that is the same type and same power details below please contact customer services on 0345 208 8750 or visit mda russellhobbs com 1 Rem...

Страница 20: ...Put the replacement light module into the fitting ensuring the terminal is threaded through the fitting and connect it to the terminal 5 Replace the front panel a cross headed screwdriver will be nee...

Страница 21: ...act Product Care or a local engineer The lighting does not work The plug is not plugged in Connect the appliance to the electricity supply The bulbs are faulty For information on changing the bulbs se...

Страница 22: ...ceed as follows The GREEN YELLOW wire is the EARTH and must be connected to the terminal which is marked with the letter E or by the earth symbol or coloured GREEN or GREEN YELLOW The BLUE wire is the...

Страница 23: ...tion of Product Care The following conditions apply Product Care will require a valid proof of purchase at the point of replacement or refund The product must be installed and used in accordance with...

Страница 24: ...ecification Model number RHSCH601SS M B M RHSCH901SS M B M Rated Voltage 220V 240V 50Hz Rated input 128W External Dimensions HxWxD 690 960 mm x 600 900mm x 500mm Extraction rate 420m h Light power 2 x...

Страница 25: ...25 Notes...

Страница 26: ...26 Notes...

Страница 27: ...27 Notes...

Страница 28: ...e Only discard electrical electronic battery items in separate collection schemes which cater for the recovery and recycling of materials contained within Your co operation is vital to ensure the succ...