WARNING!

 First of all switch off the unit and remove the plug from the wall socket.

Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, 
detergents or other cleansing solutions.

Clean the screen filter regularly with a vacuum cleaner. See also “Air Filters” section.

NOTE!

 Never use the air conditioner without the screen filter.

 CLEANING

 • Switch off the unit and remove the plug from the mains. 
 • Remove the water stopper and rubber plug. 
 • Connect a drain tube (ø 20 mm inner dimension) onto the water outlet and extend with 

extra water tube if needed. 

 • Place the other end in a normal drain. Make sure that the tube is free from twists and 

bends. The tube must decline over its entire length.

 CONTINUOUS DRAINAGE

Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty 
and can endanger the user and the property.

Problem

Cause

Solution

The air 
conditioner does 
not function.

No power supply.

Connect to a functioning outlet and switch on.

Is the LCD light flashing.

Empty the internal water container.

Timer function is active.

Deactivate TIMER function.

The air 
conditioner does 
not seem to 
perform.

In direct sunlight. 

Close curtains.

Windows or doors open, many 
people or a heat source in the room.

Close doors and windows, place an extra air 
conditioner.

Dirty filter.

Clean or replace the filter(s).

Air inlet or air outlet blocked.

Remove the blockage.

Room temperature lower than the 
selected value.

Change temperature selection.

The unit is noisy. Unit stands uneven.

Place on an even, solid surface (less 
vibrations).

The compressor 
does not work.

The overheat protection is probably 
activated.

Wait 3 minutes until the temperature has 
decreased, then turn on the unit again.

The remote 
control does not 
function.

Distance too great.

Make sure the remote control is correctly 
aimed at the control panel.

Remote control signal not detected 
by the control panel.
The batteries are drained.

Replace the batteries.

To correct problems that have not been described in the table and/or if the recommended solutions fail 
to solve the problem, contact an authorized service centre. 

TROUBLE SHOOTING

Содержание RHMA 050

Страница 1: ...INSTRUCTIONS WARRANTY MODEL RHMA 050 MOBILE AIR CONDITIONER...

Страница 2: ...cut off plug dispose of safely to prevent the hazard of electric shock Mains AC Operation This appliance is designed to operate on 220 240V current only Connecting to other power sources may damage t...

Страница 3: ...f necessary modified by a qualified electrician The air conditioner is safe However as with other electrical appliances use it with care Keep out of the reach of children Do not clean the air conditio...

Страница 4: ...5 8 7 9 3 1 Air outlet 2 Control panel 3 Carrying handle 4 Caster wheels 5 Grill housing 6 Upper air inlet 7 Exhaust air outlet 8 Lower air inlet 9 Cable storage 10 Drainage point with water stopper...

Страница 5: ...o fill as much open space as possible Put the slide bar connector in the opening in the telescopic slide bar Close the window or door as much as possible to prevent outside air entering the room Ensur...

Страница 6: ...e timer is set After 10 seconds the time display returns Programming the timer for ON when the unit is OFF Perform the standard steps as described above The linear time scale will be on between the ON...

Страница 7: ...gments in the linear time scale will disappear LCD blue back light In order to switch off the blue back light press the and buttons at the same time The blue back light will blink twice and goes off a...

Страница 8: ...filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room environment The filter holder on the rear of the unit can...

Страница 9: ...m to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The screen filter must always be used 3M is a trademark of the 3M Company Emptying the internal...

Страница 10: ...functioning outlet and switch on Is the LCD light flashing Empty the internal water container Timer function is active Deactivate TIMER function The air conditioner does not seem to perform In direct...

Страница 11: ...dren Reminder Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment technical data Model RHMA050 Cooling...

Страница 12: ...e in terms of the aforesaid warranty within the first 7 days from the date of purchase the faulty product will be exchanged provided that the product is in its original packaging with all accessories...

Отзывы: