RUSH MH 6 Wash
™
User Manual
17
2. Use the DOWN and UP buttons to select the behavior:
-
Select BLACKOUT if you want the fixture to black out if the DMX
signal is lost.
-
Select HOLD if you want the fixture to continue showing the effect that
it is displaying when the DMX signal is lost.
3. Press ENTER to save your selection.
Dimming curves
Four dimming modes are available:
MODE 1
LINEAR. The increase in light intensity appears to be linear as
DMX value is increased.
MODE 2
SQUARE LAW – light intensity control is finer at low levels and
coarser at high levels.
MODE 3
INVERSE SQUARE LAW – light intensity control is coarser at low
levels and finer at high levels.
MODE 4
S-CURVE – light intensity control is finer at low levels and high
levels and coarser at medium levels.
To set the fixture’s dimmer curve:
1. Select DIMMER CURVE and press ENTER to confirm. The mode that is
currently active will blink in the display.
2. Use the DOWN and UP buttons to select MODE1, MODE2, MODE3 or
MODE4.
3. Press ENTER to save your selection.
Dimmer speed
There are two dimmer speed options:
•
SNAP is the default setting. It sets the dimmer to exactly follow changes in
dimming level sent from the controller. This gives the fastest dimmer
response.
•
FADE adds a two-second (approx.) smooth fade to changes in dimming
level sent from the controller. This gives the smoothest dimmer fading.