16
MH 3 Beam user manual
To set the fixture’s DMX address:
1. Select DMX FUNCTIONS and press the ENTER button
2. Use the UP and DOWN buttons to select DMX ADDRESS and press the
ENTER button to confirm. The present address will blink on the display.
3. Use the UP and DOWN buttons to select the address (1 to 512).
4. Once the address has been selected, press the ENTER button to set it. To
return to the higher level of the menu structure without any change press
the MENU button again.
Fixture settings
Pan and/or tilt inversion
The FIXTURE SETTINGS
→
PAN INVERSE and TILT INVERSE menus can be
used to reverse the direction of pan and/or tilt. These settings are useful for
symmetrical effects with multiple fixtures, or when coordinating the movement
of fixtures that are floor mounted and rigged upside down.
To adjust the pan inversion settings:
1. Select FIXTURE SETTINGS and press the ENTER button to confirm.
2. Use the DOWN and UP buttons to select PAN INVERSE or TILT INVERSE
and press the ENTER button to confirm.
3. Use the DOWN and UP buttons to select the YES (inversion) or NO
(normal) mode.
4. Press the ENTER button to confirm (or, to return to the higher level of the
menu structure without any change press the MENU button).
Pan/tilt feedback
When pan/tilt feedback is enabled and a pan or tilt position error is detected,
the fixture will correct the pan/tilt position.
To deactivate, or activate this function use the FIXTURE SETTINGS
→
P/T
FEEDBACK menu.
Blackout during change or movement
The fixture can be set, so that when running a show, blackout is enabled
during gobo change, color change, and/or pan and tilt movement. This is
switched off by default. To adjust the blackout during show playback settings:
1. Select FIXTURE SETTINGS and press the ENTER button to confirm.
2. Use the DOWN and UP buttons to select BL. O. P/T MOVING, BL. O.
COLOR CHANGE, or BL. O: GOBO CHANGE and press the ENTER
Содержание MH-3 Beam