EN
13
8. PROBLEMS AND REMEDIAL ACTIONS
PROBLEMS
POSSIBLE CAUSES
REMEDIES
THE HYDROPHORE
DOES NOT PUMP
WATER, THE ENGINE
DOES NOT WORK
1. It is not powered
2. Engine protection
triggered
3. Defective capacitor
4. Rotor blocked
5. The pressure switch is
installed incorrectly or is
damaged
1. Check that the
voltage is present
and that the correct
plug has been
inserted into the
socket.
2. Determine the
cause of the
problem and reset
the switch. If the
thermal switch has
been activated, wait
for it to cool down.
3. Contact the
service.
4. Check the cause
and unlock the
hydrophore.
5. Contact the
service.
THE ENGINE IS
WORKING, BUT THE
HYDROPHORE DOES
NOT PUMP THE
LIQUID
1. Empty the
body of the
hydrophore.
2. The air inlet
from the
suction pipe.
3. The suction height is
below the recommended
value for the unit.
1. Switch off the water pump
and fill the body with water
using the filling valve (fig. 1, no.
9).
Check as:
a) the connections are sealed.
b) the fluid level did not fall
below the suction.
c) the sorbet is sealed and
blocked.
d) there are no siphons, elbows,
obstacles or strangulations.
3. Check and reduce the suction
height or use equipment with
suitable characteristics
Содержание AquaPower 1008S
Страница 1: ...Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 39: ...HU RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S Hidrofor ...
Страница 77: ...EN Hydrophore RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 91: ...BG Хидрофор RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 107: ...PL RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 120: ...SRB HRV BIH Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...