EN
10
Use a suction pipe (2) with a diameter equal to that of the hydrophore suction hole (1). If
the height (HA) is over 4 meters use a pipe with a larger diameter. The suction circuit
must be perfectly airtight. There must be no elbows or slopes to prevent the formation of
air bags that could affect the efficiency of the hydrophore. A sorb with filter valve (3) (4)
must be mounted about half a meter below the level of the pump to be pumped (HI) at
one end of the circuit. Load losses can be reduced using discharge pipes with equal or
greater diameter than the hydrophore hole (5). It is recommended to install a directional
flap (6) directly on the discharge circuit to prevent damage to the hydrophore.
A sectioning valve (7) below the check valve must also be installed to facilitate service
operations. The pipes must be placed in such a way that the vibrations, if any, the voltage
and mass do not affect the hydrophore. The pipes must be pulled on the straightest and
shortest route, avoiding the use of an excessive number of elbows. Check that the engine
is ventilated properly. For permanent installations, it is recommended to fix the
hydrophore on the support or connect the system with a rigid pipe section and insert a
layer of rubber (or other anti-vibrant material) between the support and the hydrophore
to reduce vibrations. The installation site must be stable and dry to ensure the stability of
the hydrophore.
ATTENTION
!
The connections, suction and discharge pipes must be connected with the utmost care.
Make sure that all connections attached to the screws are sealed. Avoid applying
excessive force to tighten the screws of the connections or other components. Use the
Teflon strip to completely seal all joints.
In order to use continuously the hydrophore in a tank for swimming pools, garden pools
and other similar installations, it is necessary to fix the hydrophore on a stable support.
Mobile hydrophores for swimming pools, garden pools and other similar installations may
be used only if no person is in contact with water or if the electrical system has a protective
switch. The hydrophore must be placed in a fixed position to avoid falling and protect it
from flooding. Contact a specialist electrician.
Electrical connections
Содержание AquaPower 1008S
Страница 1: ...Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 39: ...HU RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S Hidrofor ...
Страница 77: ...EN Hydrophore RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 91: ...BG Хидрофор RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 107: ...PL RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Страница 120: ...SRB HRV BIH Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...