 Coil Length 

628mm 

 Coil Thickness 

φ

7.5mm (Suitable for use in narrow environments and cable densely packed 

place, etc.) 

 The Measured 

Current   Frequency 

50Hz/60Hz(Automatic) 

 Meter Size 

190mm×370mm×40mm 

 LCD Size 

35mm×21.5mm; Display domain: 32mm×15mm 

 Backlight 

with backlight, convenient to use in dark site 

 Weight 

200g 

 Electric Field 

Interference 

No hysteresis effect, strong anti-interference ability 

Position Error 

The measured wire should be in the center of the flexible coil as far as possible, 

not close to the opening and closing mouth, the test error at the opening and 

closing mouth will increase by one times or more 

 Sampling Rate 

2 times /second 

 Data Storage 

99units, flash display “FULL” symbol indicate storage full 

 Peak Hold 

Peak value capture and hold function, long press POWER key display peak 

value, and the “   ” symbol display 

 Data Hold 

Data hold 

function: “DH” symbol display 

 Line Voltage 

Below AC 600V circuit measurement 

 Overflow Display 

Exceed measure range overflow function: “OL” symbol display 

 Battery Voltage 

While battery voltage is lower than 7.2V. low battery voltage symbol display, 

remind to replace the battery 

 Rated Current  

About 8mA 

 Working 

environment 

-10

~40

below 80%rh 

 Store environment  -10

~60

below 70%rh 

 Insulation 

Resistance 

100MΩ or large more,1000V 

Suitable Safety 

Standard 

IEC1010-1

IEC1010-2-032

Pollution 2

CAT VI(1000V) ,IEC61326(EMC 

standard) 

 

 

 

 

 

 

Содержание VR-690

Страница 1: ...www victorruoshui co kr VictorRuoshui Flexible Coil Clamp Large Current Meter VR 690 USER S MANUAL...

Страница 2: ...or test wires Do not place and store the meter in high temperature and humidity or dewy places and under direct sunlight for a long time The meter and flexible clamp must be maintained regularly keep...

Страница 3: ...en thousands of amperes Flexible coil without any exposed metal conductor non contact measurement safe and reliable Small size light weight soft and flexible suitable for narrow environment and flat c...

Страница 4: ...ng and closing mouth will increase by one times or more Sampling Rate 2 times second Data Storage 99units flash display FULL symbol indicate storage full Peak Hold Peak value capture and hold function...

Страница 5: ...VictorRuoshui 4 Meter Structure 4 1 Flexible Coil 4 2 Lock catch Turn back and forth according arrow to lock or open the coil 4 3 POWER key 4 4 LCD 4 5 HOLD Key 4 6 Meter front cover 4 7 Meter back c...

Страница 6: ...k catch according to the OPEN direction in the above meter structure diagram unscrew the flexible coil lock catch clamp the measured wire with flexible coil clamp and then rotate the lock catch as to...

Страница 7: ...ing and return to measuring mode 5 4 2 Press HOLD POWER keys to enter into data access mode and display Unit 1 storage data automatically and then press HOLD key again to turn the page and access stor...

Страница 8: ...ase replace the battery 8 2 Press POWER key to shut down the meter and confirm the meter is in off state and then open the battery cover please attention batter model and then replace with qualified n...

Отзывы: