Installation
Runco VX-33d Installation/Operation Manual
43
PRE
L
IMINAR
Y
Configure Lens Motor
Trigger (CineWide with
AutoScope)
CineWide with AutoScope maintains constant image height independent of the aspect
ratio, while using the full display resolution of the projector. It accomplishes this by moving
the anamorphic lens in front of the primary lens when widescreen material is being viewed.
When the viewer transitions back to 16:9 or 4:3 source material, the anamorphic lens
moves out of the light path.
To configure the lens motor trigger on the DHD Controller for proper AutoScope
operation:
1.
Project a 2.35:1 aspect ratio test pattern or other image on the screen.
2.
Press
MENU
on the remote control and enter the Service menu passcode.
3.
Select
Service
from the Main menu.
4.
Select
Triggers
from the Service menu.
5.
Assign the trigger output to which the lens motor is connected to the Cinema and
Virtual Cinema aspect ratios. This enables the lens motor to move the anamorphic
lens into position (in front of the primary lens) when either aspect ratio is selected.
6.
To save the trigger settings, press
repeatedly to highlight “Save.” Then, press
ENTER
.
7.
Select the Cinema aspect ratio to move the anamorphic lens into position, if it isn’t
already. To do this, press
CINEMA
on the DHD Controller remote control (Figure 2-5),
or press
or
repeatedly with no menus visible on-screen.
Adjust the Anamorphic
Lens
Adjusting the Horizontal (X) Lens Position:
1. Project a white field on the screen.
2. Loosen the Yaw/X-Adjustment Levers underneath the lens.
3. Slowly move the anamorphic lens into place so that there are no shadows on either
side of the screen:
4. When the horizontal position is properly set, tighten the Yaw/X-Adjustment Levers to
secure the lens in place.
Too Far Right
Too Far Left
Correct position
Содержание VX VIDEO XTREME VX-33D
Страница 2: ......
Страница 10: ...x Runco VX 33d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 14: ...Table of Contents xiv Runco VX 33d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 16: ...List of Figures xvi Runco VX 33d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 80: ...Maintenance and Troubleshooting 64 Runco VX 33d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 86: ...Serial Communications 70 Runco VX 33d Installation Operation Manual P R E L I M I N A R Y Notes ...
Страница 93: ......
Страница 94: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1004 00 rev A September 2009 ...