Hardware Installation and Reference Guide
Product Overview
- 7 -
(Rear panel)
Solid red
1) One of the modules of the system fails.
2) There are less than 3 fans.
3) The internal or partial temperature exceeds the
warning working temperature, and the switching
service resets.
Blinking green.
The system is being initialized.
Solid green
The system is operational.
Solid yellow
1) The temperature exceeds the warning threshold.
2) Only 3 fans are in the position.
3) One of the power module is not plugged in with a
power cable in 1+1 power redundancy mode.
BMC indicator (Rear
Panel)
BMC
Off
The BMC module is not in place or does not work.
Solid green
The BMC module works properly.
Blinking green
The BMC module is being initialized.
Fan indicator (Rear
panel)
FAN
Off
The system is not powered on.
Blinking green
The fan modules are being initialized.
Solid green
The fan modules work properly.
Solid yellow
One fan module does not work.
Solid red
The fan module is not in place or more than one fan
module do not work.
Power indicator (Rear
panel)
PWR
Off
The system is not powered on.
Blinking green
The power modules are being initialized.
Solid green
The power modules work properly.
Solid yellow
One power module does not work.
Solid red
More than one fan module do not work.
ID indicator
(Rear panel)
ID
Off
Locator is disabled.
Solid blue
Locator is enabled.
MGMT port indicator
LINK/ACT
LINK Off
The port is not connected.
LINK Solid Green
The port is connected at 1000Mbps.
LINK Solid Yellow
The port is connected at 100Mbps.
ACT Off
The port is not transmitting or receiving data.
ACT Blinking
Green
The port is transmitting or receiving data.
QSFP28 port indicator
(Front panel)
1F-32F
Off
The port is not connected.
Solid green
The port is connected at 40G/100Gbps.
Blinking green
The port is transmitting or receiving data at
40G/100Gbps.
Power Supply
The RG-S6920-4C series switches support power supply the RG-PA1200I-F. The smart power supply module supports
power management, and the host can read input power, input current, and temperature in real time. The power supply
module supports hot swapping.