Ruijie RG-NBS5100 Series Switches Hardware Installation and Reference Guide
Product Overview
7
LED
LED
Panel Identification
State
Meaning
System status LED
Status
Off
The switch is not receiving power.
Blinking green
(0.5Hz)
The switch is running, but is not connected to
Ruijie Cloud.
Blinking green
(10Hz)
The switch is being upgraded or initialized.
Solid green
The switch is connected to Ruijie Cloud.
10/100/1000Base-T
Ethernet port status
LED
1-24
Off
The port is not connected.
Solid green
The port is connected at 10/100/1000 Mbps.
Blinking green
The port is receiving or transmitting traffic.
SFP port status LED
25F-28F
Off
The port is not connected.
Solid green
The port is connected.
Blinking green
The port is receiving or transmitting traffic.
1.2 RG-NBS5100-48GT4SFP
Technical Specifications
Model
RG-NBS5100-48GT4SFP
CPU
Built-in CPU, dual-core processor, 1GHz
BOOTROM
N/A
Flash Memory
256 MB
SDRAM
DDRIII 1GB
Optical Module
See
Appendix B
.
The copper cable is not supported.
The supported module type may change at any time. Consult Ruijie Networks for the latest
information.
SFP Port
1000Base-X
Power Supply
AC input
Rated voltage range: 100V to 240V
Maximum voltage range: 90V to 264V
Frequency: 50/60 Hz
Rated current: 2A
Input
Leakage
Current
≤
3.5mA
EEE
Supported
PoE
Not supported
Power
Consumption
46W
Temperature
Operating temperature: 0 ºC to 50ºC
Storage temperature: -40 ºC to 70ºC
Humidity
Operating humidity: 10% to 90% RH