Hardware Installation and Reference Guide                                                                            Appendix A Connectors and Media 

 

 

Appendix A Connectors and Media 

1000BASE-T/100BASE-TX/10BASE-T 

The 1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps auto-negotiation port that supports auto MDI/MDIX.   

Compliant with IEEE 802.3ab, 1000BASE-T requires Category 5e 100-ohm UTP or STP (STP is recommended) with a 

maximum distance of 100 meters (328 feet).             

1000BASE-T requires all four pairs of wires be connected for data transmission, as shown in Figure A-1.       

Figure A-1 1000BASE-T Connection 

 

10BASE-T  uses  Category  3,  4,  5  100-ohm  UTP/STP  and  1000BASE-T  uses  Category  5  100-ohm  UTP/STP  for 

connections. Both support a maximum length of 100 meters. Table A-1 shows 100BASE-TX/10BASE-T pin assignments. 

Table A-2 100BASE-TX/10BASE-T Pin Assignments     

 

Figure A-3 shows wiring of straight-through and crossover cables for 100BASE-TX/10BASE-T. 

Figure A-3 100BASE-TX/10BASE-T Connection 

 

Содержание RG-EAP602 Series

Страница 1: ...Ruijie RG EAP602 Series Access Points Hardware Installation and Reference Guide...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Страница 4: ...G EAP602 Dimensions 222 mm 200 mm 166 mm Access Rate Built in antenna 1166Mbps 2 4GHz up to 300Mbp 5GHz up to 866Mbps Operating Frequency 802 11b g n 2 4 GHz to 2 483 GHz 802 11a n ac 5 150 GHz to 5 3...

Страница 5: ...for 505ms Restore factory settings blinking at a rate of 14Hz on for 20ms and off for 50ms System upgrade blinking at a rate of 10Hz on for 40ms and off for 60ms Solid on CWMP is not connected Off Po...

Страница 6: ...port 3 10 100 1000BASE T Ethernet port PoE port 4 Reset button 5 Waterproof cap 1 3 Power Supply The AP supports 802 3af PoE or 12V DC power supply If needed you can buy the adapter from Ruijie When...

Страница 7: ...rt support 6kV lightning protection If a lightning protector of a higher profile is available configure the lightning protector optionally Before the configuration connect the lightning protector to t...

Страница 8: ...r devices The interference source can be part of disrupted system or a fully electrically isolated unit Conduction interference occurs when interference is transferred from one unit to another through...

Страница 9: ...tallation and Reference Guide Preparing for Installation 2 4 Checking before Installation Please check your materials carefully against the package contents If there are any errors please contact your...

Страница 10: ...read the requirements described in Chapter 2 3 1 Installation Flowchart 3 2 Before You Begin Before you install the AP verify that all the parts in the package contents are there and make sure that T...

Страница 11: ...the power supply make sure the external power supply matches the power module inside the AP Before connecting the power cord make sure the power switch is in the OFF position When connecting a wire to...

Страница 12: ...ttach the bracket to a pole with hose clamps and fasten the clamps with screws and nuts Figure 3 3 Mounting the Bracket on a Pole b Align the host with bracket and mounting plate to the bracket on the...

Страница 13: ...and Reference Guide Installing the Access Point Pole mount Horizontal Figure 3 5 Mounting the Bracket on a Pole Figure 3 6 Horizontal Pole Mounting The horizontal pole mounting is the same with the v...

Страница 14: ...h the LAN1 PoE uplink port of AP and tighten the waterproof plug in the order of B C and D to complete the installation 5 To install the waterproof port not connected with the network cable Insert the...

Страница 15: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...

Страница 16: ...erence Guide Appendix A Connectors and Media Fiber Connection You can choose to use single mode or multimode fibers according to the transceiver module types Figure A 4 shows connection of fiber cable...

Страница 17: ...ansmit dBm Max Receive dBm Standards FE SFP LX MM 1310 1310 MMF1 62 5 125 2 km 14 14 IEEE802 3 FE SFP LH15 S M1310 1310 SMF2 9 125 15 km 8 8 MINI GBIC SX MM850 850 MMF1 62 5 62 5 50 0 50 0 160 200 400...

Отзывы: