Hardware Installation and Reference Guide Installing the Access Point
3.3 Precautions
RG-EAP602 can be mounted on a wall and a pole (diameter: 50mm to 70mm, thickness:
≥
2.5mm). Otherwise, the AP
could fall down and cause injuries. The installation site can vary due to on-the-spot surveys conducted by technical
personnel.
Please make full preparations as described in Chapter 2 and observe the following precautions before installing the AP.
Before connecting the power supply, make sure the external power supply matches the power module inside the AP.
Before connecting the power cord, make sure the power switch is in the OFF position.
When connecting a wire to a binding post, make sure their colors are the same.
Make sure the power supply is properly connected.
3.4 Installing the AP
Wall mount
Use M8 x 60 screws to implement the wall mount.
a.
Attach the bracket to the wall and mark the screw hole locations.
Figure 3-1 Installing the Bracket
b.
Align the host with bracket and mounting plate to the bracket on the wall, and tighten the M8×40 screws to complete
installation.
Figure 3-2 Mounting the Bracket on Wall