Hardware Installation and Reference GuideAppendix B Mini-GBIC Modules 

 

7  Appendix B Mini-GBIC Modules 

We provide appropriate SFP modules (Mini-GBIC) modules according to the types of interfaces of the switch modules. 

You can select the module to suit your specific needs. The 100M/1000M SFP module supports the following modules as 

well as the 100M/1000M fiber/copper conversion SFP module (Mini-GBIC-GT). The following models and technical 

specifications of some 100M/1000M SFP modules are listed for your reference. 

Models and Technical Specifications of the Mini-GBIC (SFP) Module 

Table B-1 Models and Technical Specifications of the 100M SFP Modules 

100M Mini-GBIC   

(SFP) 

Wavelength 

(nm) 

Media Type 

Core 

Size 

(

μm) 

Cabling 

Distance 

Intensity of 

Transmitte

d Light 

(dBm) 

Intensity of 

Received 

Light 

(dBm) 

 

Suppor

t DDM 

(Yes/No)

 

min 

max 

min 

max 

FE-SFP-LX-MM1310 

1,310 

Multi-mode 

fiber 

62.5/125 

2km 

-22 

-14 

-30 

-14 

Yes 

FE-SFP-LH15-SM1310 

1,310 

Single-mode 

fiber 

9/125 

15km 

-15 

-8 

-28 

-8 

Yes 

Table B-2Models and Technical Specifications of the 1000M SFP Modules 

1000M Mini-GBIC   

(SFP) 

Wavelength 

(nm) 

Media Type 

Core 

Size 

(

μm) 

Cabling 

Distance 

Intensity of 

Transmitte

d Light 

(dBm) 

Intensity of 

Received 

Light 

(dBm) 

 

Suppor

t DDM 

(Yes/No)

 

min 

max 

min 

max 

MINI-GBIC-SX-MM850 

850 

Multi-mode 

fiber 

62.5/125 

275m 

-9.5 

-3 

-17 

No 

50/125 

550m 

MINI-GBIC-LX-SM1310 

1,310 

Single-mode 

fiber 

9/125 

10km 

-9.5 

-3 

-20 

-3 

No 

GE-eSFP-SX-MM850 

850 

Multi-mode 

fiber 

62.5/125 

275m 

-9.5 

-3 

-17 

Yes 

50/125 

550m 

GE-eSFP-LX-SM1310 

1,310 

Single-mode 

fiber 

9/125 

10km 

-9.5 

-3 

-20 

-3 

Yes 

MINI-GBIC-LH40-SM13

10 

1,310 

Single-mode 

fiber 

9/125 

40km 

-2 

-22 

-3 

Yes 

MINI-GBIC-ZX50-SM15

50 

1,550 

Single-mode 

fiber 

9/125 

50km 

-5 

-22 

-3 

Yes 

MINI-GBIC-ZX80-SM15

50 

1,550 

Single-mode 

fiber 

9/125 

80km 

4.7 

-22 

-3 

Yes 

Содержание XS-S1960-24GT4SFP-H

Страница 1: ...XS S1960 24GT4SFP H Series Switch Hardware Installation and Reference Guide V1 02...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...ted by the product with configuration examples Command Reference Describes the related configuration commands including command modes parameter descriptions usage guides and related examples Symbol Co...

Страница 4: ...cess solutions Table 1 1 XS S1960 24GT4SFP HSeries Model 10 100 1000B ASE T adaptive Ethernet Port 1000BASE X SFP Port Console Port USB Port Extension Module Slot Pluggable Power Supply Module Slot XS...

Страница 5: ...perature Warning Supported EMC Standards GB9254 2008 Safety Standards GB4943 2011 Dimensions W x D x H 440mm x 260mm x 43 6mm Weight 3 5kg XS S1960 24GT4SFP H switch is a classA product In a domestic...

Страница 6: ...el Figure 1 2Front Panel of theXS S1960 24GT4SFP H Note 1 Reset button 2 System status indicator 3 Console port 4 10 100 1000BASE T adaptive Ethernet ports 5 SFP ports 6 SFP ports 7 10 100 1000BASE T...

Страница 7: ...um voltage range 90V to 264V 47Hz to 63Hz Frequency 50Hz 60Hz Rated current 0 6A Power cord 10A power cord HVDC input Rated voltage range 192V to 290V Rated current range 0 1A to 0 5A Heat Dissipation...

Страница 8: ...tialized Solid green The system is in normal operation Solid red 1 Over temperature alarm Serious over temperature causes system restart 2 The system is faulty 10 100 1000BASE T adaptive Ethernet port...

Страница 9: ...Electric Safety Observe local regulations and specifications when performing electric operations Relevant operators must be qualified Before installing the device carefully check any potential danger...

Страница 10: ...may easily occur due to high sensitivity and thus the leakage protector trips devices are powered off and services are interrupted To guarantee personal safety the rated leakage action current of eac...

Страница 11: ...humidity however the insulating strip may dry and shrink Static electricity may occur easily and endanger the circuit on the equipment In an environment with high temperature the equipment is subject...

Страница 12: ...nding systems and wires power cables signal cables and outgoing transmission cables For that purpose note that For the AC power supply system TN single phase three core power socket with protective ea...

Страница 13: ...on The cross sectional area of each pin should be at least 0 75mm2 18AWG Lightning Grounding The lightning protection system of a facility is an independent system that consists of the lightning rod d...

Страница 14: ...om the electromagnetic wire or signal cable connection between the source and the sensitive component along which cable the interference conducts from one unit to another Conducted interference often...

Страница 15: ...et 3 1 Installation Procedure 3 2 Confirmations before Installation Before installation please confirm the following points Whether ventilation requirements are met for the switch Whether the requirem...

Страница 16: ...uency large current devices If necessary electromagnetic shielding should be adopted For example use interface cables to shield cables 100 meter network cables should be laid inside the equipment room...

Страница 17: ...the Rack 3 3 2 Mounting the Switch onthe Wall The XS S1960 24GT4SFP Hseries switches can be mounted on a wall Step 1 Take out supplied screws and brackets And then rotate the brackets by 90 when it is...

Страница 18: ...es suitable for mounting on concrete or other non combustiblesurface only 3 3 3 Mounting the Switch to a Workbench In some cases users do not have the 19 inch standard cabinet The common solution is t...

Страница 19: ...ower supply so as to avoid any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly co...

Страница 20: ...with DB 9 jack to the serial port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HyperTerminal Parameters Step 1 Start the PC and run the ter...

Страница 21: ...s shown in Figure 4 3 is displayed Choose the serial port used currently in the column use when connecting Figure 4 3 After choosing the serial port click OK to display the serial port parameter setti...

Страница 22: ...onsole port of the switch The hyperterminal is started and the parameter settings are correct 4 2 2 Checking after Program Startup Recommended After power on you are recommended to perform the followi...

Страница 23: ...ical support The status indicator is not on after the switch is started The power supply module does not supply power The power cable is in loose contact Check whether the power socket at the equipmen...

Страница 24: ...le exceeds 100 m The port has special configuration that has no common working mode with the connected switch Replace the twisted pair cable Check that the port configuration has the common working mo...

Страница 25: ...rt uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000B...

Страница 26: ...Connection Media Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic...

Страница 27: ...ity of Received Light dBm Suppor t DDM Yes No min max min max FE SFP LX MM1310 1 310 Multi mode fiber 62 5 125 2km 22 14 30 14 Yes FE SFP LH15 SM1310 1 310 Single mode fiber 9 125 15km 15 8 28 8 Yes T...

Страница 28: ...P LX20 SM1550 BIDI 100M 40km FE SFP LH40 SM1310 BIDI FE SFP LH40 SM1550 BIDI BIDI SFP modules have to be used in pairs For instance if GE SFP LX20 SM1310 BIDI is applied at one end then GE SFP LX20 SM...

Страница 29: ...the practical requirement Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After the switch AC power plug is connected to the socket of the pow...

Страница 30: ...ten the grounding line to the grounding terminal of the switch 3 Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the f...

Страница 31: ...able to the IN end and connect the switch Ethernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with...

Страница 32: ...over seven times greater than their respective diameters After cabling is fixed the bend radius of a common coaxial cable should be over seven times greater than its diameter The bend radius of this...

Страница 33: ...et should be smoothwithout sharp corners The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables...

Страница 34: ...V and 48V power cords cannot be bundled on the guide rails of moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled to...

Страница 35: ...minal connection and cable Do not use self tapping screws to fasten terminals Power cables of the same type and in the same cabling direction should be bundled up into cable bunches with cables in cab...

Страница 36: ...ppendix D Cabling Recommendations in Installation For wiring terminal blocks such as air switches of the cold pressing terminal type the metal part of the cold pressing terminal should not be exposed...

Страница 37: ...windstorm and heavy rain as well as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwi...

Отзывы: